{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:11:08Z","timestamp":1761005468824,"version":"build-2065373602"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","funder":[{"name":"MRC T","award":["Development Gap Fund"],"award-info":[{"award-number":["Development Gap Fund"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>(a) To compare performance by cochlear-implant listeners on a melodic contour identification task when the fundamental frequency (F0) is encoded explicitly by single-pulse-per-period (SPP) pulse trains presented to an apical channel, by amplitude modulation of high-rate pulse trains presented to several electrodes, and by these two methods combined, (b) to measure melodic contour identification as a function of the range of F0s tested, (c) to determine whether so-called asymmetric phantom stimulation improves melodic contour identification relative to monopolar stimulation, as has been shown previously using pitch-ranking tasks.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Three experiments measured melodic contour identification by cochlear-implant listeners with two different methods of encoding fundamental frequency (F0), both singly and in combination. One method presented SPP pulse trains at the F0 rate to an apical channel in either partial-bipolar or monopolar mode. The second method applied amplitude modulation at F0 to high-rate (~2000 pulses per second) pulse trains on six adjacent electrodes. For this \u201cMOD\u201d stimulation, the channel envelopes were misaligned so as to simulate the effects of the bandpass filters in the commercial signal-processing strategy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In experiment 1, the SPP stimulation used the asymmetric phantom method: pseudomonophasic pulses were applied in partial-bipolar mode to electrodes 1 and 3, with 25% of current returned via an extra-cochlear electrode, and with the short high-amplitude phase anodic with respect to electrode 1. The MOD stimuli were presented to a set of basal electrodes. Performance for SPP stimulation was better, both when presented alone and when combined with MOD stimulation, relative to MOD stimulation alone. Performance was also better when the range of F0s present in the stimuli spanned a low range (97 to 194 Hz) than when they spanned a medium (161 to 322 Hz) or a high range (242 to 484 Hz). Experiment 2 was similar to experiment 1 except that the MOD stimuli were presented to a set of six apical electrodes. Performance with SPP stimulation alone was again significantly better than with MOD stimulation, but the difference between combined and MOD stimulation was not significant. Experiment 3 compared performance of SPP stimulation applied in asymmetric phantom mode to monopolar stimulation of the most-apical electrode using symmetric biphasic pulses. No differences were found between these two types of stimulation, either presented in isolation or with MOD stimulation of nearby apical electrodes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The results show that F0 encoding by SPP stimulation was better than with MOD stimulation, that it was robust to possible interference from MOD-stimulated electrodes, but that performance with combined stimulation was not better than with SPP alone. Contrary to previous data from pitch-ranking studies, we found no evidence that asymmetric phantom improved melodic contour identification compared with the monopolar stimulation used in commercial strategies.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000001691","type":"journal-article","created":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T10:00:23Z","timestamp":1751536823000},"page":"1550-1559","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Melodic Contour Identification by Cochlear-Implant Listeners With Asymmetric Phantom Pulses Presented to Apical Electrodes"],"prefix":"10.1097","volume":"46","author":[{"given":"Olivier","family":"Macherey","sequence":"first","affiliation":[{"name":"Aix Marseille University, Centre National de la Recherche Scientifique, Centrale Marseille, Laboratoire de M\u00e9canique et d\u2019Acoustique, Marseille, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert P.","family":"Carlyon","sequence":"additional","affiliation":[{"name":"Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,7,3]]},"reference":[{"key":"R1-20251020","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.heares.2004.06.008","article-title":"Pulse rate discrimination with deeply inserted electrode arrays.","volume":"196","author":"Baumann","year":"2004","journal-title":"Hear Res"},{"key":"R2-20251020","doi-asserted-by":"crossref","first-page":"23312165251317006","DOI":"10.1177\/23312165251317006","article-title":"Limitations on temporal processing by cochlear implant users: A compilation of viewpoints.","volume":"29","author":"Carlyon","year":"2025","journal-title":"Trends Hear"},{"key":"R3-20251020","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s10162-021-00811-5","article-title":"Cochlear implant research and development in the twenty-first century: A critical update.","volume":"22","author":"Carlyon","year":"2021","journal-title":"J Assoc Res Otolaryngol"},{"key":"R4-20251020","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1007\/s10162-016-0569-5","article-title":"Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users.","volume":"17","author":"Cosentino","year":"2016","journal-title":"J Assoc Res Otolaryngol"},{"key":"R6-20251020","doi-asserted-by":"crossref","first-page":"424","DOI":"10.3109\/14992027.2014.989455","article-title":"Speech perception with F0mod, a cochlear implant pitch coding strategy.","volume":"54","author":"Francart","year":"2015","journal-title":"Int J Audiol"},{"key":"R7-20251020","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/01.aud.0000261689.35445.20","article-title":"Melodic contour identification by cochlear implant listeners.","volume":"28","author":"Galvin","year":"2007","journal-title":"Ear Hear"},{"key":"R8-20251020","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s10162-021-00828-w","article-title":"Advantages of pulse rate compared to modulation frequency for temporal pitch perception in cochlear implant users.","volume":"23","author":"Goldsworthy","year":"2022","journal-title":"J Assoc Res Otolaryngol"},{"key":"R9-20251020","doi-asserted-by":"crossref","first-page":"108319","DOI":"10.1016\/j.heares.2021.108319","article-title":"Pitch perception is more robust to interference and better resolved when provided by pulse rate than by modulation frequency of cochlear implant stimulation.","volume":"409","author":"Goldsworthy","year":"2021","journal-title":"Hear Res"},{"key":"R10-20251020","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1121\/1.1925827","article-title":"Enhancement of temporal periodicity cues in cochlear implants: Effects on prosodic perception and vowel identification.","volume":"118","author":"Green","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R11-20251020","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1080\/14992020601053340","article-title":"Use of a single channel dedicated to conveying enhanced temporal periodicity cues in cochlear implants: Effects on prosodic perception and vowel identification.","volume":"46","author":"Hamilton","year":"2007","journal-title":"Int J Audiol"},{"key":"R12-20251020","first-page":"363","article-title":"Coding of voice source information in the Nucleus cochlear implant system.","volume":"166","author":"Jones","year":"1995","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"R13-20251020","doi-asserted-by":"crossref","first-page":"3114","DOI":"10.1121\/1.3372713","article-title":"Temporal pitch perception at high rates in cochlear implants.","volume":"127","author":"Kong","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R14-20251020","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1121\/1.3068457","article-title":"Limits of temporal pitch in cochlear implants.","volume":"125","author":"Kong","year":"2009","journal-title":"J Acoust Soc Am"},{"key":"R15-20251020","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/s10162-020-00768-x","article-title":"The effect of phantom stimulation and pseudomonophasic pulse shapes on pitch perception by cochlear implant listeners.","volume":"21","author":"Lamping","year":"2020","journal-title":"J Assoc Res Otolaryngol"},{"key":"R16-20251020","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.jneumeth.2004.08.015","article-title":"A flexible auditory research platform using acoustic or electric stimuli for adults and young children.","volume":"142","author":"Laneau","year":"2005","journal-title":"J Neurosci Methods"},{"key":"R18-20251020","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1121\/1.3269042","article-title":"Temporal pitch percepts elicited by dual-channel stimulation of a cochlear implant.","volume":"127","author":"Macherey","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R19-20251020","doi-asserted-by":"crossref","first-page":"2225","DOI":"10.1121\/1.3677260","article-title":"Place-pitch manipulations with cochlear implants.","volume":"131","author":"Macherey","year":"2012","journal-title":"J Acoust Soc Am"},{"key":"R20-20251020","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s10162-010-0248-x","article-title":"Extending the limits of place and temporal pitch perception in cochlear implant users.","volume":"12","author":"Macherey","year":"2011","journal-title":"J Assoc Res Otolaryngol"},{"key":"R21-20251020","doi-asserted-by":"crossref","first-page":"2664","DOI":"10.1121\/1.411377","article-title":"Pitch percepts associated with amplitude-modulated current pulse trains in cochlear implantees.","volume":"96","author":"McKay","year":"1994","journal-title":"J Acoust Soc Am"},{"key":"R35-20251020","doi-asserted-by":"crossref","first-page":"2260","DOI":"10.1121\/1.3085642","article-title":"Improved fundamental frequency coding in cochlear implant signal processing.","volume":"125","author":"Milczynski","year":"2009","journal-title":"J Acoust Soc Am"},{"key":"R23-20251020","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2009\/531213","article-title":"Signal processing strategies for cochlear implants using current steering.","volume":"2009","author":"Nogueira","year":"2009","journal-title":"EURASIP J Adv Signal Process"},{"key":"R24-20251020","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.heares.2012.12.006","article-title":"Masking patterns for monopolar and phantom electrode stimulation in cochlear implants.","volume":"298","author":"Saoji","year":"2013","journal-title":"Hear Res"},{"key":"R25-20251020","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1097\/AUD.0b013e3181e1d15e","article-title":"Use of \u201cphantom electrode\u201d technique to extend the range of pitches available through a cochlear implant.","volume":"31","author":"Saoji","year":"2010","journal-title":"Ear Hear"},{"key":"R26-20251020","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1080\/14992020400050056","article-title":"Supplementary formulas and tables for calculating and interconverting speech recognition scores in transformed arcsine units.","volume":"43","author":"Sherbecoe","year":"2004","journal-title":"Int J Audiol"},{"key":"R27-20251020","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1121\/1.4944564","article-title":"Rate discrimination at low pulse rates in normal-hearing and cochlear implant listeners: Influence of intracochlear stimulation site.","volume":"139","author":"Stahl","year":"2016","journal-title":"J Acoust Soc Am"},{"key":"R28-20251020","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1044\/jshr.2803.455","article-title":"A \u201crationalized\u201d arcsine transform.","volume":"28","author":"Studebaker","year":"1985","journal-title":"J Speech Hear Res"},{"key":"R29-20251020","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1121\/1.395554","article-title":"Pitch perception by cochlear implant subjects.","volume":"82","author":"Townshend","year":"1987","journal-title":"J Acoust Soc Am"},{"key":"R30-20251020","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1097\/AUD.0000000000000627","article-title":"Evaluation of the optimized pitch and language strategy in cochlear implant recipients.","volume":"40","author":"Vandali","year":"2019","journal-title":"Ear Hear"},{"key":"R31-20251020","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.heares.2013.05.004","article-title":"Pitch and loudness matching of unmodulated and modulated stimuli in cochlear implantees.","volume":"302","author":"Vandali","year":"2013","journal-title":"Hear Res"},{"key":"R32-20251020","doi-asserted-by":"crossref","first-page":"3126","DOI":"10.1121\/1.1874632","article-title":"Pitch ranking ability of cochlear implant recipients: A comparison of sound-processing strategies.","volume":"117","author":"Vandali","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R33-20251020","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.heares.2004.06.002","article-title":"Mandarin tone recognition in cochlear-implant subjects.","volume":"197","author":"Wei","year":"2004","journal-title":"Hear Res"},{"key":"R34-20251020","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1038\/352236a0","article-title":"Better speech recognition with cochlear implants.","volume":"352","author":"Wilson","year":"1991","journal-title":"Nature"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001691","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T05:02:05Z","timestamp":1760936525000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001691"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,3]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001691","relation":{},"ISSN":["1538-4667"],"issn-type":[{"type":"electronic","value":"1538-4667"}],"subject":[],"published":{"date-parts":[[2025,7,3]]}}}