{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T03:15:32Z","timestamp":1788923732653,"version":"build-2803163510"},"reference-count":66,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T00:00:00Z","timestamp":1763596800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>Speech perception remains challenging for cochlear-implant recipients in conditions containing background noise. The sound processing strategy of the cochlear implant transforms the acoustic signal into a pattern of electrical stimulation pulses, which are transmitted by the electrode array. Modifications to the sound processing strategy could improve the transmission of information by the cochlear implant, alleviating speech perception difficulties in noise. One such modification, the temporal integrator processing strategy (TIPS), uses a model of temporal masking to identify and remove stimulation pulses that are unlikely to be perceived. In a previous investigation, TIPS significantly improved the perception of continuous interleaved sampling-processed speech in the presence of speech-shaped noise while reducing the power required for stimulation (Lamping et al. 2020). This study extends the previous investigation to include conditions that better reflect everyday listening for cochlear-implant recipients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Two pre-registered double-blind within-participant experiments measured the speech-recognition performance of 12 cochlear implant listeners for sentences before and after TIPS processing. Experiments 1 and 2 investigated TIPS performance against the Continuous Interleaved Sampling or Advanced Combination Encoder baseline speech processing strategies, respectively. Speech-reception thresholds were measured in a speech-shaped noise (in experiment 1) and a multi-talker noise (in experiments 1 and 2), and mean-opinion score speech quality ratings were obtained in quiet (in experiments 1 and 2). In both experiments, all strategies used the subjects\u2019 clinical pulse rate, inter-phase gap, phase duration, and ground electrodes, and participants were acclimatized for 10\u2009min before testing each strategy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      In experiments 1 and 2, the median speech-reception thresholds obtained were comparable across the baseline and TIPS strategies, with no statistical differences noted in either speech-shaped or multi-talker noise. Quality ratings were lower for TIPS when compared to the Continuous Interleaved Sampling strategy (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.044) but not when compared to the Advanced Combination Encoder strategy, which all participants used as their everyday strategy. In all conditions, TIPS could reduce device power consumption by between 21% and 42%.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>TIPS could result in substantial power savings, without compromising speech quality or speech intelligibility in noise. Although some individuals demonstrated improved speech-reception thresholds with TIPS, the significant group-level improvement previously found by Lamping et al. (2020) was not observed in this study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000001741","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T05:01:03Z","timestamp":1763614863000},"page":"453-464","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["An Evaluation of the Temporal Integrator Processing Strategy for Cochlear Implants in Comparison to the Clinical Strategy and in Multi-Talker Noise"],"prefix":"10.1097","volume":"47","author":[{"given":"Lidea","family":"Shahidi","sequence":"first","affiliation":[{"name":"Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert P.","family":"Carlyon","sequence":"additional","affiliation":[{"name":"Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah A.","family":"Vickers","sequence":"additional","affiliation":[{"name":"Cambridge Hearing Group, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Goehring","sequence":"additional","affiliation":[{"name":"Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,11,20]]},"reference":[{"key":"R1-20260217","doi-asserted-by":"crossref","first-page":"123","DOI":"10.3109\/14992027.2010.527860","article-title":"Effects of stimulation rate on modulation detection and speech recognition by cochlear implant users.","volume":"50","author":"Arora","year":"2011","journal-title":"Int J Audiol"},{"key":"R2-20260217","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1080\/14992027.2024.2314620","article-title":"Effect of reducing electrical stimulation rate on hearing performance of Nucleus\u00ae cochlear implant recipients.","volume":"64","author":"Arora","year":"2024","journal-title":"Int J Audiol"},{"key":"R3-20260217","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1016\/j.otohns.2007.01.006","article-title":"Nucleus Freedom North American clinical trial.","volume":"136","author":"Balkany","year":"2007","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R4-20260217","first-page":"3508","article-title":"The 1st clarity prediction challenge: A machine learning challenge for hearing aid intelligibility prediction.","volume":"2022","author":"Barker","year":"2022","journal-title":"Proc Interspeech"},{"key":"R5-20260217","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v067.i01","article-title":"Fitting linear mixed-effects models using lme4.","volume":"67","author":"Bates","year":"2015","journal-title":"J Stat Softw"},{"key":"R6-20260217","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1121\/1.5092350","article-title":"Speech recognition as a function of the number of channels in perimodiolar electrode recipients.","volume":"145","author":"Berg","year":"2019","journal-title":"J Acoust Soc Am"},{"key":"R7-20260217","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1044\/2023_AJA-22-00032","article-title":"Effects of the number of channels and channel stimulation rate on speech recognition and sound quality using precurved electrode arrays.","volume":"32","author":"Berg","year":"2023","journal-title":"Am J Audiol"},{"key":"R8-20260217","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s10162-015-0545-5","article-title":"Temporal considerations for stimulating spiral ganglion neurons with cochlear implants.","volume":"17","author":"Boulet","year":"2016","journal-title":"J Assoc Res Otolaryngol"},{"key":"R9-20260217","doi-asserted-by":"crossref","first-page":"2801","DOI":"10.1121\/1.1479152","article-title":"Efficient adaptive procedures for threshold and concurrent slope estimates for psychophysics and speech intelligibility tests.","volume":"111","author":"Brand","year":"2002","journal-title":"J Acoust Soc Am"},{"key":"R10-20260217","doi-asserted-by":"crossref","first-page":"4097","DOI":"10.1121\/1.4983658","article-title":"The effect of presentation level and stimulation rate on speech perception and modulation detection for cochlear implant users.","volume":"141","author":"Brochier","year":"2017","journal-title":"J Acoust Soc Am"},{"key":"R11-20260217","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1179\/1754762811Y0000000009","article-title":"Clinical evaluation of cochlear implant sound coding taking into account conjectural masking functions, MP3000TM.","volume":"12","author":"Buechner","year":"2011","journal-title":"Cochlear Implants Int"},{"key":"R12-20260217","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s10162-021-00811-5","article-title":"Cochlear implant research and development in the twenty-first century: A critical update.","volume":"22","author":"Carlyon","year":"2021","journal-title":"J Assoc Res Otolaryngol"},{"key":"R13-20260217","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/s10162-006-0068-1","article-title":"Concurrent sound segregation in electric and acoustic hearing.","volume":"8","author":"Carlyon","year":"2007","journal-title":"J Assoc Res Otolaryngol"},{"key":"R14-20260217","article-title":"Susceptibility to steady noise largely explains susceptibility to dynamic maskers in cochlear implant users, but not in normal-hearing listeners.","volume":"27","author":"Chen","year":"2023","journal-title":"Trends Hear"},{"key":"R15-20260217","doi-asserted-by":"crossref","first-page":"EL537","DOI":"10.1121\/1.5016044","article-title":"Re-examining the relationship between number of cochlear implant channels and maximal speech intelligibility.","volume":"142","author":"Croghan","year":"2017","journal-title":"J Acoust Soc Am"},{"key":"R16-20260217","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1121\/1.2805617","article-title":"Speech recognition with varying numbers and types of competing talkers by normal-hearing, cochlear-implant, and implant simulation subjects.","volume":"123","author":"Cullington","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R17-20260217","doi-asserted-by":"crossref","first-page":"80","DOI":"10.3109\/14992027.2015.1070309","article-title":"Characteristics and international comparability of the Finnish matrix sentence test in cochlear implant recipients.","volume":"54","author":"Dietz","year":"2015","journal-title":"Int J Audiol"},{"key":"R18-20260217","doi-asserted-by":"crossref","first-page":"3019","DOI":"10.1044\/2017_JSLHR-H-17-0035","article-title":"Speech understanding in complex listening environments by listeners fit with cochlear implants.","volume":"60","author":"Dorman","year":"2017","journal-title":"J Speech Lang Hear Res"},{"key":"R19-20260217","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1121\/1.419603","article-title":"Speech intelligibility as a function of the number of channels of stimulation for signal processors using sine-wave and noise-band outputs.","volume":"102","author":"Dorman","year":"1997","journal-title":"J Acoust Soc Am"},{"key":"R20-20260217","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1097\/01.AUD.0000134552.22205.EE","article-title":"Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems.","volume":"25","author":"Firszt","year":"2004","journal-title":"Ear Hear"},{"key":"R21-20260217","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1121\/1.1381538","article-title":"Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants.","volume":"110","author":"Friesen","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R22-20260217","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1159\/000084027","article-title":"Effects of stimulation rate on speech recognition with cochlear implants.","volume":"10","author":"Friesen","year":"2005","journal-title":"Audiol Neurootol"},{"key":"R23-20260217","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s10162-004-5024-3","article-title":"Noise susceptibility of cochlear implant users: The role of spectral resolution and smearing.","volume":"6","author":"Fu","year":"2005","journal-title":"J Assoc Res Otolaryngol"},{"key":"R24-20260217","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1121\/1.428325","article-title":"Effect of stimulation rate on phoneme recognition by Nucleus-22 cochlear implant listeners.","volume":"107","author":"Fu","year":"2000","journal-title":"J Acoust Soc Am"},{"key":"R25-20260217","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1080\/14992027.2017.1367848","article-title":"Tolerable delay for speech production and perception: Effects of hearing ability and experience with hearing aids.","volume":"57","author":"Goehring","year":"2018","journal-title":"Int J Audiol"},{"key":"R26-20260217","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1007\/s10162-020-00758-z","article-title":"Using spectral blurring to assess effects of channel interaction on speech-in-noise perception with cochlear implants.","volume":"21","author":"Goehring","year":"2020","journal-title":"J Assoc Res Otolaryngol"},{"key":"R27-20260217","doi-asserted-by":"crossref","first-page":"10383","DOI":"10.1038\/s41598-021-89932-8","article-title":"The effect of increased channel interaction on speech perception with cochlear implants.","volume":"11","author":"Goehring","year":"2021","journal-title":"Sci Rep"},{"key":"R28-20260217","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/AUD.0000000000001282","article-title":"Dynamic current focusing compared to monopolar stimulation in a take-home trial of cochlear implant users.","volume":"44","author":"van Groesen","year":"2023","journal-title":"Ear Hear"},{"key":"R29-20260217","doi-asserted-by":"crossref","first-page":"2372","DOI":"10.1121\/1.423772","article-title":"Gap detection as a measure of electrode interaction in cochlear implants.","volume":"104","author":"Hanekom","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R30-20260217","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1080\/14992020802644871","article-title":"Audiovisual asynchrony detection and speech perception in hearing-impaired listeners with cochlear implants: A preliminary analysis.","volume":"48","author":"Hay-McCutcheon","year":"2009","journal-title":"Int J Audiol"},{"key":"R31-20260217","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1121\/1.1287711","article-title":"The relationship between speech perception and electrode discrimination in cochlear implantees.","volume":"108","author":"Henry","year":"2000","journal-title":"J Acoust Soc Am"},{"key":"R33-20260217","doi-asserted-by":"crossref","first-page":"895","DOI":"10.3109\/14992027.2014.938368","article-title":"Investigation of a matrix sentence test in noise: Reproducibility and discrimination function in cochlear implant patients.","volume":"53","author":"Hey","year":"2014","journal-title":"Int J Audiol"},{"key":"R34-20260217","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1177\/000348940010901105","article-title":"Optimized speech understanding with the continuous interleaved sampling speech coding strategy in patients with cochlear implants: Effect of variations in stimulation rate and number of channels.","volume":"109","author":"Kiefer","year":"2000","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R35-20260217","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.foodqual.2014.08.004","article-title":"Automated mixed ANOVA modeling of sensory and consumer data.","volume":"40","author":"Kuznetsova","year":"2015","journal-title":"Food Qual Prefer"},{"key":"R36-20260217","doi-asserted-by":"crossref","first-page":"107969","DOI":"10.1016\/j.heares.2020.107969","article-title":"The effect of a coding strategy that removes temporally masked pulses on speech perception by cochlear implant users.","volume":"391","author":"Lamping","year":"2020","journal-title":"Hear Res"},{"key":"R39-20260217","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1121\/1.429612","article-title":"The effect of parametric variations of cochlear implant processors on speech understanding.","volume":"108","author":"Loizou","year":"2000","journal-title":"J Acoust Soc Am"},{"key":"R40-20260217","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1007\/s10162-015-0511-2","article-title":"Perceptual interactions between electrodes using focused and monopolar cochlear stimulation.","volume":"16","author":"Marozeau","year":"2015","journal-title":"J Assoc Res Otolaryngol"},{"key":"R41-20260217","doi-asserted-by":"crossref","first-page":"3367","DOI":"10.1121\/1.402826","article-title":"A new portable sound processor for the University of Melbourne\/Nucleus Limited multielectrode cochlear implant.","volume":"91","author":"McDermott","year":"1992","journal-title":"J Acoust Soc Am"},{"key":"R42-20260217","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1121\/1.416294","article-title":"The perception of temporal patterns for electrical stimulation presented at one or two intracochlear sites.","volume":"100","author":"McKay","year":"1996","journal-title":"J Acoust Soc Am"},{"key":"R43-20260217","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1121\/1.1394222","article-title":"Loudness summation for pulsatile electrical stimulation of the cochlea: Effects of rate, electrode separation level, and mode of stimulation.","volume":"110","author":"McKay","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R44-20260217","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s10162-012-0354-z","article-title":"Temporal processing in the auditory system.","volume":"14","author":"McKay","year":"2013","journal-title":"J Assoc Res Otolaryngol"},{"key":"R45-20260217","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s10162-022-00834-6","article-title":"Modulation depth discrimination by cochlear implant users.","volume":"23","author":"Monaghan","year":"2022","journal-title":"J Assoc Res Otolaryngol"},{"key":"R47-20260217","doi-asserted-by":"crossref","first-page":"2921","DOI":"10.1121\/1.1371762","article-title":"Psychophysical recovery from single-pulse forward masking in electric hearing.","volume":"109","author":"Nelson","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R48-20260217","first-page":"3044","article-title":"A psychoacoustic \u201cNofM\u201d-type speech coding strategy for cochlear implants.","volume":"18","author":"Nogueira","year":"2005","journal-title":"EURASIP J Appl Signal Process"},{"key":"R49-20260217","doi-asserted-by":"crossref","first-page":"549","DOI":"10.2307\/2530245","article-title":"A multiple testing procedure for clinical trials.","volume":"35","author":"O\u2019Brien","year":"1979","journal-title":"Biometrics"},{"key":"R50-20260217","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1097\/AUD.0b013e31820fc821","article-title":"Digit training in noise can improve cochlear implant users\u2019 speech understanding in noise.","volume":"32","author":"Oba","year":"2011","journal-title":"Ear Hear"},{"key":"R51-20260217","doi-asserted-by":"crossref","first-page":"2331216514553783","DOI":"10.1177\/2331216514553783","article-title":"Speech perception in tones and noise via cochlear implants reveals influence of spectral resolution on temporal processing.","volume":"18","author":"Oxenham","year":"2014","journal-title":"Trends Hear"},{"key":"R52-20260217","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/0378-5955(94)90014-0","article-title":"Modeling the additivity of nonsimultaneous masking.","volume":"80","author":"Oxenham","year":"1994","journal-title":"Hear Res"},{"key":"R53-20260217","doi-asserted-by":"crossref","first-page":"6","DOI":"10.7874\/kja.2012.16.1.6","article-title":"Effects of electrical stimulation rate on speech recognition in cochlear implant users.","volume":"16","author":"Park","year":"2012","journal-title":"Korean J Audiol"},{"key":"R54-20260217","first-page":"348","article-title":"Linear and nonlinear processes in temporal masking.","volume":"88","author":"Plack","year":"2002","journal-title":"Acta Acust United With Acust"},{"key":"R55-20260217","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1080\/14992027.2023.2185757","article-title":"Evaluation of the American English matrix test with cochlear implant recipients.","volume":"63","author":"Potts","year":"2023","journal-title":"Int J Audiol"},{"key":"R56-20260217","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1159\/000360479","article-title":"Long-term improvement of speech perception with the fine structure processing coding strategy in cochlear implants.","volume":"76","author":"Punte","year":"2014","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"R57-20260217","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1080\/14670100.2017.1359457","article-title":"Effects of electrode deactivation on speech recognition in multichannel cochlear implant recipients.","volume":"18","author":"Schvartz-Leyzac","year":"2017","journal-title":"Cochlear Implants Int"},{"key":"R58-20260217","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1080\/00031305.1980.10483031","article-title":"Population marginal means in the linear model: An alternative to least squares means.","volume":"34","author":"Searle","year":"1980","journal-title":"Am Statistician"},{"key":"R59-20260217","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1080\/14992027.2017.1317370","article-title":"Development and evaluation of the British English coordinate response measure speech-in-noise test as an occupational hearing assessment tool.","volume":"56","author":"Semeraro","year":"2017","journal-title":"Int J Audiol"},{"key":"R61-20260217","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0378-5955(83)90115-6","article-title":"Multichannel electrical stimulation of the auditory nerve in man. II. Channel interaction.","volume":"12","author":"Shannon","year":"1983","journal-title":"Hear Res"},{"key":"R62-20260217","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00003446-200206000-00005","article-title":"Speech recognition with the Nucleus 24 SPEAK, ACE, and CIS speech coding strategies in newly implanted adults.","volume":"23","author":"Skinner","year":"2002","journal-title":"Ear Hear"},{"key":"R64-20260217","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1121\/1.4877139","article-title":"Hearing better with interaural time differences and bilateral cochlear implants.","volume":"135","author":"Smith","year":"2014","journal-title":"J Acoust Soc Am"},{"key":"R65-20260217","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1121\/1.1772399","article-title":"Cochlear implant speech recognition with speech maskers.","volume":"116","author":"Stickney","year":"2004","journal-title":"J Acoust Soc Am"},{"key":"R67-20260217","doi-asserted-by":"crossref","first-page":"5872","DOI":"10.3390\/jcm11195872","article-title":"The effect of age, type of noise, and cochlear implants on adaptive sentence-in-noise task.","volume":"11","author":"Taitelbaum-Swead","year":"2022","journal-title":"J Clin Med"},{"key":"R68-20260217","doi-asserted-by":"crossref","first-page":"817","DOI":"10.3109\/14992027.2014.922223","article-title":"Investigation into the applicability and optimization of the Dutch matrix sentence test for use with cochlear implant users.","volume":"53","author":"Theelen-van Den Hoek","year":"2014","journal-title":"Int J Audiol"},{"key":"R69-20260217","doi-asserted-by":"crossref","first-page":"EL112","DOI":"10.1121\/1.5049701","article-title":"The effect of polarity order and electrode-activation order on loudness in cochlear implant users.","volume":"144","author":"Todd","year":"2018","journal-title":"J Acoust Soc Am"},{"key":"R70-20260217","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1121\/1.395554","article-title":"Pitch perception by cochlear implant subjects.","volume":"82","author":"Townshend","year":"1987","journal-title":"J Acoust Soc Am"},{"key":"R71-20260217","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1097\/00003446-200012000-00008","article-title":"Speech perception as a function of electrical stimulation rate: Using the Nucleus 24 cochlear implant system.","volume":"21","author":"Vandali","year":"2000","journal-title":"Ear Hear"},{"key":"R72-20260217","doi-asserted-by":"crossref","first-page":"46S","DOI":"10.1097\/AUD.0b013e3180315442","article-title":"Performance and preference for ACE stimulation rates obtained with nucleus RP 8 and Freedom System.","volume":"28","author":"Weber","year":"2007","journal-title":"Ear Hear"},{"key":"R73-20260217","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1038\/352236a0","article-title":"Better speech recognition with cochlear implants.","volume":"352","author":"Wilson","year":"1991","journal-title":"Nature"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001741","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T15:00:43Z","timestamp":1771340443000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001741"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,20]]},"references-count":66,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001741","relation":{},"ISSN":["1538-4667"],"issn-type":[{"value":"1538-4667","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,20]]}}}