{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:39:13Z","timestamp":1787841553127,"version":"build-2784847793"},"reference-count":52,"publisher":"Ovid Technologies (Wolters Kluwer Health)","funder":[{"DOI":"10.13039\/100000055","name":"NIDCD","doi-asserted-by":"crossref","award":["R01 DC018307"],"award-info":[{"award-number":["R01 DC018307"]}],"id":[{"id":"10.13039\/100000055","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>\n                      To use otoacoustic emissions (OAEs) for the serial monitoring of hearing or the tracking of hearing loss, test\u2013retest reliability must be known, and normal OAE level variation must be established. Past studies have defined the reliability of distortion-product OAEs (DPOAEs) evoked with stimuli calibrated in a conventional manner (in-the-ear, dB sound pressure level), which can produce inaccuracies due to ear-canal standing waves. In the present study, we make within-subject comparisons of test reliability for conventionally measured 2\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>1<\/jats:sub>\n                      -\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>2<\/jats:sub>\n                      DPOAEs compared with DPOAEs evoked by stimulus tones calibrated in dB forward pressure level (dB FPL) to mitigate the effect of standing waves. We also define the test\u2013retest reliability of the stimulus-frequency OAE (SFOAE).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Conventional DPOAEs evoked by discrete tones calibrated in dB SPL as well as DPOAEs and SFOAEs evoked by swept tones calibrated in dB FPL were measured in the same ear of 20 adult subjects every 2 mo over the course of 1 yr. OAE test reliability was assessed for each OAE paradigm by calculating absolute level differences, standard errors of the measurement, and 95% normative shift limits. Comparisons in reliability were made between conventional DPOAEs and those using dB FPL calibration and between DPOAEs and SFOAEs, both evoked by stimuli calibrated in dB FPL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Results indicate that overall DPOAEs evoked by swept tones calibrated in dB FPL have significantly better test\u2013retest reliability than do conventional DPOAEs. Swept-tone DPOAEs also showed better reliability than swept-tone SFOAEs at mid-to-high frequencies, though at low frequencies test-to-test variation was comparable. In a subgroup of 5 subjects showing mild declines in audiometric hearing during the study, we found that DPOAEs and SFOAEs evoked by stimuli calibrated in dB FPL detected most instances of audiometric decline while conventional DPOAEs did not.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>FPL-based calibration of stimulus level reduces test-to-test variation in DPOAE level compared with conventional in-the-ear SPL methods. By creating a tighter distribution of natural or typical OAE level fluctuations on repeated testing, forward pressure calibration appears to improve the serial monitoring of OAEs and could provide earlier detection of slight hearing changes. Our preliminary look at this question should be further explored with a large group of individuals showing confirmed changes in hearing over time.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000001883","type":"journal-article","created":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:00:39Z","timestamp":1787763639000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Serial Monitoring of Hearing With Otoacoustic Emissions: Effects of Forward Pressure Level Calibration"],"prefix":"10.1097","author":[{"given":"Carolina","family":"Abdala","sequence":"first","affiliation":[{"name":"Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tricia","family":"Benjamin","sequence":"additional","affiliation":[{"name":"Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samantha","family":"Stiepan","sequence":"additional","affiliation":[{"name":"Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ping","family":"Luo","sequence":"additional","affiliation":[{"name":"Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher A.","family":"Shera","sequence":"additional","affiliation":[{"name":"Auditory Research Center, Caruso Department of Otolaryngology, University of Southern California, Los Angeles, California, USA"},{"name":"Department of Physics and Astronomy, University of Southern California, Los Angeles, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,25]]},"reference":[{"key":"R1-20260827","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1097\/AUD.0000000000001765","article-title":"Distinguishing between presbycusis and noise-induced hearing loss with a joint-OAE profile.","volume":"47","author":"Abdala","year":"2026","journal-title":"Ear Hear"},{"key":"R2-20260827","doi-asserted-by":"crossref","first-page":"2220","DOI":"10.1121\/10.0030399","article-title":"Detection of mild sensory hearing loss using a joint reflection-distortion otoacoustic emission profile.","volume":"156","author":"Abdala","year":"2024","journal-title":"J Acoust Soc Am"},{"key":"R3-20260827","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1121\/1.3268611","article-title":"Distortion product otoacoustic emission phase and component analysis in human newborns.","volume":"127","author":"Abdala","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R4-20260827","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s10162-012-0319-2","article-title":"Maturation and aging of the human cochlear: A view through the DPOAE looking glass.","volume":"13","author":"Abdala","year":"2012","journal-title":"J Assoc Res Otolaryngol"},{"key":"R5-20260827","doi-asserted-by":"crossref","first-page":"3123","DOI":"10.1121\/1.3573992","article-title":"Level dependence of distortion product otoacoustic emission phase is attributed to component mixing.","volume":"129","author":"Abdala","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R6-20260827","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1121\/1.5020275","article-title":"Swept-tone stimulus-frequency otoacoustic emissions: Normative data and methodological considerations.","volume":"143","author":"Abdala","year":"2018","journal-title":"J Acoust Soc Am"},{"key":"R7-20260827","doi-asserted-by":"crossref","first-page":"3785","DOI":"10.1121\/1.4937611","article-title":"Optimizing swept-tone protocols for recording distortion-product otoacoustic emissions in adults and newborns.","volume":"138","author":"Abdala","year":"2015","journal-title":"J Acoust Soc Am"},{"key":"R8-20260827","first-page":"PS664","article-title":"Comparison of methods for DPOAE component unmixing.","volume":"39","author":"Abdala","year":"2016","journal-title":"Assoc Res Otolaryngol Abs"},{"key":"R9-20260827","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1007\/s10162-022-00857-z","article-title":"Characterizing the relationship between reflection and distortion otoacoustic emissions in normal-hearing adults.","volume":"23","author":"Abdala","year":"2022","journal-title":"J Assoc Res Otolaryngol"},{"key":"R10-20260827","doi-asserted-by":"crossref","first-page":"e271","DOI":"10.1097\/MAO.0000000000001071","article-title":"Temporary and permanent threshold shifts: A review of basic and clinical observations.","volume":"37","author":"Allen","year":"2016","journal-title":"Otol Neurotol"},{"key":"R11-20260827","first-page":"11","article-title":"Guidelines for the audiological management of individuals receiving cochleotoxic drug therapy.","volume":"36","year":"1994","journal-title":"ASHA"},{"key":"R13-20260827","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1097\/AUD.0000000000001522","article-title":"Reliable long-term serial evaluation of cochlear function using pulsed distortion-product otoacoustic emissions: Analyzing levels and pressure time courses.","volume":"45","author":"Bader","year":"2024","journal-title":"Ear Hear"},{"key":"R14-20260827","doi-asserted-by":"crossref","first-page":"305","DOI":"10.3109\/03005364000000142","article-title":"Effects of sample size on the reliability of noise floor and DPOAE.","volume":"34","author":"Beattie","year":"2000","journal-title":"Br J Audiol"},{"key":"R15-20260827","doi-asserted-by":"crossref","first-page":"348","DOI":"10.3109\/14992020309101328","article-title":"Immediate and short-term reliability of distortion-product otoacoustic emissions.","volume":"42","author":"Beattie","year":"2003","journal-title":"Int J Audiol"},{"key":"R16-20260827","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1121\/1.4973618","article-title":"Compensating for ear-canal acoustics when measuring otoacoustic emissions.","volume":"141","author":"Charaziak","year":"2017","journal-title":"J Acoust Soc Am"},{"key":"R17-20260827","first-page":"493","article-title":"Uses and Abuses of hearing loss classification.","volume":"23","author":"Clark","year":"1981","journal-title":"ASHA"},{"key":"R18-20260827","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1097\/01.aud.0000233892.37803.1a","article-title":"Repeatability of high-frequency distortion-product otoacoustic emissions in normal-hearing adults.","volume":"27","author":"Dreisbach","year":"2006","journal-title":"Ear Hear"},{"key":"R19-20260827","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/AUD.0000000000000465","article-title":"High-frequency distortion-product otoacoustic emission repeatability in a patient population.","volume":"39","author":"Dreisbach","year":"2018","journal-title":"Ear Hear"},{"key":"R20-20260827","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/00003446-199212000-00008","article-title":"Test\/retest reliability of distortion-product and transiently evoked otoacoustic emissions.","volume":"13","author":"Franklin","year":"1992","journal-title":"Ear Hear"},{"key":"R21-20260827","doi-asserted-by":"crossref","first-page":"107922","DOI":"10.1016\/j.heares.2020.107922","article-title":"Extended high frequency hearing and speech perception implications in adults and children.","volume":"397","author":"Hunter","year":"2020","journal-title":"Hear Res"},{"key":"R22-20260827","doi-asserted-by":"crossref","first-page":"3562","DOI":"10.1121\/1.2793604","article-title":"Comparing stimulus-frequency otoacoustic emissions measured by compression, suppression, and spectral smoothing.","volume":"122","author":"Kalluri","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R23-20260827","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1121\/1.4807505","article-title":"Measuring stimulus-frequency otoacoustic emissions using swept tones.","volume":"134","author":"Kalluri","year":"2013","journal-title":"J Acoust Soc Am"},{"key":"R24-20260827","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1121\/1.3531796","article-title":"Specification of absorbed-sound power in the ear canal: Application to suppression of stimulus frequency otoacoustic emissions.","volume":"129","author":"Keefe","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R25-20260827","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/AUD.0000000000000536","article-title":"Long-term variability of distortion-product otoacoustic emissions in infants and children and its relation to pediatric ototoxicity monitoring.","volume":"41","author":"Konrad-Martin","year":"2020","journal-title":"Ear Hear"},{"key":"R26-20260827","doi-asserted-by":"crossref","first-page":"e286","DOI":"10.1097\/MAO.0000000000001134","article-title":"Serial monitoring of otoacoustic emissions in clinical trials.","volume":"37","author":"Konrad-Martin","year":"2016","journal-title":"Otol Neurotol"},{"key":"R27-20260827","doi-asserted-by":"crossref","first-page":"3431","DOI":"10.1121\/1.423054","article-title":"The level and growth behavior of the 2f1-f2 distortion product otoacoustic emission and its relationship to auditory sensitivity in normal hearing and cochlear hearing loss.","volume":"103","author":"Kummer","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R28-20260827","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1097\/AUD.0b013e31823d7917","article-title":"Behavioral hearing thresholds between 0.125 and 20\u2009kHz using depth-compensated ear simulator calibration.","volume":"33","author":"Lee","year":"2012","journal-title":"Ear Hear"},{"key":"R29-20260827","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1121\/1.2949505","article-title":"Measuring distortion product otoacoustic emissions using continuously sweeping primaries.","volume":"124","author":"Long","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R30-20260827","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1080\/14992027.2024.2418354","article-title":"Early identification of potential occupational noise-induced hearing loss: A systematic review.","volume":"64","author":"Makaruse","year":"2024","journal-title":"Int J Audiol"},{"key":"R31-20260827","doi-asserted-by":"crossref","first-page":"1345","DOI":"10.1097\/AUD.0000000000000714","article-title":"Effects of forward- and emitted-pressure calibrations on the variability of otoacoustic emission measurements across repeated probe fits.","volume":"40","author":"Maxim","year":"2019","journal-title":"Ear Hear"},{"key":"R32-20260827","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s10162-024-00943-4","article-title":"Optimal scale\u2011invariant wavelet representation and filtering of human otoacoustic emissions.","volume":"25","author":"Moleti","year":"2024","journal-title":"J Assoc Res Otolaryngol"},{"key":"R33-20260827","doi-asserted-by":"crossref","first-page":"2455","DOI":"10.1121\/1.4751537","article-title":"Time-frequency domain filtering of evoked otoacoustic emissions.","volume":"132","author":"Moleti","year":"2012","journal-title":"J Acoust Soc Am"},{"key":"R35-20260827","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1080\/16513860510028284","article-title":"Test-retest reliability of distortion product otoacoustic emissions in the 1 to 7\u2009kHz range.","volume":"3","author":"Ng","year":"2005","journal-title":"Audiol Med"},{"key":"R36-20260827","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1121\/10.0017119","article-title":"Comments on forward pressure and other reflectance-based quantities for delivering stimuli to the ear.","volume":"153","author":"N\u00f8rgaard","year":"2023","journal-title":"J Acoust Soc Am"},{"key":"R37-20260827","doi-asserted-by":"crossref","first-page":"725","DOI":"10.2471\/BLT.19.230367","article-title":"Hearing loss grades and the international classification of functioning, disability and health.","volume":"97","author":"Olusanya","year":"2019","journal-title":"Bull World Health Organ"},{"key":"R38-20260827","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1121\/1.4845415","article-title":"Characteristics of the 2f1-f2 distortion product otoacoustic emission in a normal hearing population.","volume":"135","author":"Poling","year":"2014","journal-title":"J Acoust Soc Am"},{"key":"R39-20260827","doi-asserted-by":"crossref","first-page":"2391","DOI":"10.1121\/10.0010105","article-title":"The influence of self-reported noise exposure on 2\u01921-\u01922 distortion product otoacoustic emission level, fine structure, and components in a normal-hearing population.","volume":"151","author":"Poling","year":"2022","journal-title":"J Acoust Soc Am"},{"key":"R40-20260827","doi-asserted-by":"crossref","first-page":"e251","DOI":"10.1097\/AUD.0000000000000176","article-title":"Meta-analysis of distortion product otoacoustic emission retest variability for serial monitoring of cochlear function in adults.","volume":"36","author":"Reavis","year":"2015","journal-title":"Ear Hear"},{"key":"R41-20260827","doi-asserted-by":"crossref","first-page":"273","DOI":"10.3109\/00206099309072943","article-title":"Repeatability of distortion product otoacoustic emissions in normally hearing humans.","volume":"32","author":"Roede","year":"1993","journal-title":"Audiology"},{"key":"R42-20260827","doi-asserted-by":"crossref","first-page":"3882","DOI":"10.1121\/1.3655878","article-title":"Further assessment of forward pressure level for in situ calibration.","volume":"130","author":"Scheperle","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R43-20260827","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1121\/1.2931953","article-title":"Influence of in situ, sound-level calibration on distortion-product otoacoustic emission variability.","volume":"124","author":"Scheperle","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R44-20260827","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s10162-024-00934-5","article-title":"Swept along: measuring otoacoustic emissions using continuously varying stimuli.","volume":"25","author":"Shera","year":"2024","journal-title":"J Assoc Res Otolaryngol"},{"key":"R45-20260827","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1121\/1.4730916","article-title":"Obtaining reliable phase-gradient delays from otoacoustic emission data.","volume":"132","author":"Shera","year":"2012","journal-title":"J Acoust Soc Am"},{"key":"R46-20260827","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1121\/1.426948","article-title":"Evoked otoacoustic emissions arise by two fundamentally different mechanisms: A taxonomy for mammalian OAEs.","volume":"105","author":"Shera","year":"1999","journal-title":"J Acoust Soc Am"},{"key":"R55-20260827","doi-asserted-by":"crossref","first-page":"3318","DOI":"10.1073\/pnas.032675099","article-title":"Revised estimates of human cochlear tuning from otoacoustic and behavioral measurements.","volume":"99","author":"Shera","year":"2002","journal-title":"Proc Natl Acad Sci"},{"key":"R47-20260827","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/0378-5955(94)90106-6","article-title":"Sound calibration and distortion product otoacoustic emissions at high frequencies.","volume":"80","author":"Siegel","year":"1994","journal-title":"Hear Res"},{"key":"R48-20260827","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1121\/1.4894787","article-title":"Comparison of nine methods to estimate ear-canal stimulus levels.","volume":"136","author":"Souza","year":"2014","journal-title":"J Acoust Soc Am"},{"key":"R49-20260827","first-page":"SU172","article-title":"Monitoring the course of endolymphatic hydrops with a joint reflection\u2013distortion OAE profile.","volume":"47","author":"Stiepan","year":"2024","journal-title":"Assoc Res Otolaryngol Abs"},{"key":"R51-20260827","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/S0378-5955(97)00007-5","article-title":"Time-frequency distributions of click-evoked otoacoustic emissions.","volume":"106","author":"Tognola","year":"1997","journal-title":"Hear Res"},{"key":"R52-20260827","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/AUD.0b013e31816906e7","article-title":"Test\u2013retest repeatability of distortion product otoacoustic emissions.","volume":"29","author":"Wagner","year":"2008","journal-title":"Ear Hear"},{"key":"R53-20260827","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1121\/1.416065","article-title":"Visualization of the onset of distortion\u2010product otoacoustic emissions, and measurement of their latency.","volume":"100","author":"Whitehead","year":"1996","journal-title":"J Acoust Soc Am"},{"key":"R54-20260827","doi-asserted-by":"crossref","first-page":"EL544","DOI":"10.1121\/1.5016466","article-title":"Comparison of time-domain source-separation techniques for short-pulse distortion-product otoacoustic emissions.","volume":"142","author":"Zelle","year":"2017","journal-title":"J Acoust Soc Am"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/AUD.0000000000001883","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:00:16Z","timestamp":1787839216000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/AUD.0000000000001883"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,25]]},"references-count":52,"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001883","relation":{},"ISSN":["1538-4667","0196-0202"],"issn-type":[{"value":"1538-4667","type":"electronic"},{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8,25]]}}}