{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T15:08:10Z","timestamp":1789571290079,"version":"build-2803163510"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This study aims to validate vocoders as acoustic models of cochlear implants by determining whether they capture both perceptual sound quality and speech performance. We hypothesize that valid acoustic models of cochlear implants require listener-specific amounts of frequency mismatch between input filters and output tones or noise bands.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Forty-four adult single-sided deaf cochlear implant users were tested 1 to 5 times for a total of 73 sessions at different time points after initial stimulation. Participants had a cochlear implant in one ear and normal or near-normal hearing in the contralateral ear, allowing within-subject comparisons. In Experiment 1, participants used a method-of-adjustment procedure to select acoustic models most similar to their cochlear implant by adjusting three parameters: low- and high-frequency cutoffs of the acoustic output, and channel interaction (overlap among output sound carriers). In Experiment 2, participants rated the perceptual similarity of five acoustic model types using questionnaires assessing overall similarity and four acoustic dimensions (intelligibility, pleasantness, harshness, and loudness). The five model types included the self-selected model, two all-channel frequency-matched vocoders (tone and noise), and two six-channel frequency-matched vocoders (tone and noise). Frequency-matched acoustic models had output noise bands or tones that were frequency-matched to the analysis filters. In Experiment 3, speech perception was evaluated under six conditions: with the cochlear implant alone and with each of the five acoustic model types presented to the normal hearing ear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Nearly all participants (69 of 73 sessions) selected acoustic models with frequency ranges different from their clinical frequency allocation tables. The low-frequency edge of self-selected models was significantly higher than clinical allocations (456 Hz for Cochlear Ltd. and 266 Hz for MED-EL). Over 80% of selections used minimal channel interaction (tones, nonoverlapping noise bands, or adjacent noise bands). Self-selected models received significantly higher similarity ratings (mean of 6.11, where 6 means \u201csomewhat similar\u201d and 7 \u201cvery similar\u201d) compared with all frequency-matched models, which were rated around 3 (\u201cnot very similar\u201d). Self-selected models were rated most similar to the cochlear implant across multiple acoustic dimensions and were the only models not rated significantly different from the cochlear implant on any dimension. For speech perception, all-channel frequency-matched models significantly overestimated performance compared with the cochlear implant for both words and sentences. Self-selected models provided speech scores closest to cochlear implant performance. Joint analysis of similarity ratings and speech perception scores demonstrated that self-selected models were the only acoustic models achieving both perceptual similarity to the cochlear implant (rating of 6.11 with 7 being \u201cvery similar\u201d) and comparable speech perception scores (within five percentage points).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Frequency-matched acoustic models fail to replicate the sound of a cochlear implant and all-channel frequency-matched acoustic models also significantly overestimate speech perception. In contrast, self-selected acoustic models incorporating listener-specific perceptual frequency mismatch provide substantially better matches in both subjective sound quality and speech intelligibility. However, variability in similarity ratings across individuals may suggest that additional perceptual components remain unaccounted for in the current parameter set. These findings question the validity of frequency-matched acoustic models of cochlear implants in research applications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000001892","type":"journal-article","created":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T15:01:38Z","timestamp":1789570898000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["From Approximation to Validation: Rethinking Frequency-Matched Acoustic Models of Cochlear Implants"],"prefix":"10.1097","author":[{"given":"Nicole Hope","family":"Capach","sequence":"first","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahan","family":"Azadpour","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elad","family":"Sagi","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan D.","family":"Neukam","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"},{"name":"Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ariel E.","family":"Hight","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9 H.","family":"Gifford","sequence":"additional","affiliation":[{"name":"Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA"},{"name":"Hearts for Hearing, Oklahoma City, Oklahoma, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert T.","family":"Dwyer","sequence":"additional","affiliation":[{"name":"Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA"},{"name":"Clinical Research Department, Advanced Bionics, Valencia, California, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Artur","family":"Lorens","sequence":"additional","affiliation":[{"name":"Department of Auditory Implant and Perception, Institute of Physiology and Pathology of Hearing, Warsaw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marika","family":"Kruszynska","sequence":"additional","affiliation":[{"name":"Department of Auditory Implant and Perception, Institute of Physiology and Pathology of Hearing, Warsaw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annette","family":"Lavender","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"},{"name":"Cochlear Americas, Denver, Colorado, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario A.","family":"Svirsky","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology Head and Neck Surgery, New York University Grossman School of Medicine, New York, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,16]]},"reference":[{"key":"R1-20260916","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.heares.2008.04.012","article-title":"Simulating the effect of spread of excitation in cochlear implants.","volume":"241","author":"Bingabr","year":"2008","journal-title":"Hear Res"},{"key":"R2-20260916","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1159\/000503217","article-title":"Cochlear Place of stimulation is one determinant of cochlear implant sound quality.","volume":"24","author":"Dorman","year":"2019","journal-title":"Audiol Neurootol"},{"key":"R3-20260916","doi-asserted-by":"crossref","first-page":"2993","DOI":"10.1121\/1.420354","article-title":"Simulating the effect of cochlear-implant electrode insertion depth on speech understanding.","volume":"102","author":"Dorman","year":"1997","journal-title":"J Acoust Soc Am"},{"key":"R4-20260916","doi-asserted-by":"crossref","first-page":"2331216520920079","DOI":"10.1177\/2331216520920079","article-title":"Approximations to the voice of a cochlear implant: Explorations with single-sided deaf listeners.","volume":"24","author":"Dorman","year":"2020","journal-title":"Trends Hear"},{"key":"R5-20260916","doi-asserted-by":"crossref","first-page":"e268","DOI":"10.1097\/MAO.0000000000001449","article-title":"The sound quality of cochlear implants: Studies with single-sided deaf patients.","volume":"38","author":"Dorman","year":"2017","journal-title":"Otol Neurotol"},{"key":"R6-20260916","doi-asserted-by":"crossref","first-page":"3493","DOI":"10.1044\/2019_JSLHR-H-18-0389","article-title":"Looking for Mickey Mouse\u2122 But Finding a Munchkin: The perceptual effects of frequency upshifts for single-sided deaf, cochlear implant patients.","volume":"62","author":"Dorman","year":"2019","journal-title":"J Speech Lang Hear Res"},{"key":"R7-20260916","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.heares.2016.01.005","article-title":"A neural-based vocoder implementation for evaluating cochlear implant coding strategies.","volume":"333","author":"El Boghdady","year":"2016","journal-title":"Hear Res"},{"key":"R8-20260916","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1121\/1.1536928","article-title":"Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth.","volume":"113","author":"Faulkner","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R9-20260916","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1121\/1.1381538","article-title":"Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants.","volume":"110","author":"Friesen","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R10-20260916","doi-asserted-by":"crossref","first-page":"3586","DOI":"10.1121\/1.423941","article-title":"Effects of noise and spectral resolution on vowel and consonant recognition: Acoustic and electric hearing.","volume":"104","author":"Fu","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R11-20260916","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1097\/AUD.0000000000000541","article-title":"The effect of simulated interaural frequency mismatch on speech understanding and spatial release from masking.","volume":"39","author":"Goupell","year":"2018","journal-title":"Ear Hear"},{"key":"R12-20260916","doi-asserted-by":"crossref","first-page":"EL484","DOI":"10.1121\/1.5009602","article-title":"Cochlear implant simulator with independent representation of the full spiral ganglion.","volume":"142","author":"Grange","year":"2017","journal-title":"J Acoust Soc Am"},{"key":"R14-20260916","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1121\/1.4890642","article-title":"Optimizing pulse-spreading harmonic complexes to minimize intrinsic modulations after auditory filtering.","volume":"136","author":"Hilkhuysen","year":"2014","journal-title":"J Acoust Soc Am"},{"key":"R15-20260916","first-page":"S83","article-title":"The HSM sentence test as a tool for evaluating the speech understanding in noise of cochlear implant users.","volume":"18","author":"Hochmair-Desoyer","year":"1997","journal-title":"Am J Otol"},{"key":"R16-20260916","doi-asserted-by":"crossref","first-page":"2331216519866029","DOI":"10.1177\/2331216519866029","article-title":"Searching for the sound of a cochlear implant: Evaluation of different vocoder parameters by cochlear implant users with single-sided deafness.","volume":"23","author":"Karoui","year":"2019","journal-title":"Trends Hear"},{"key":"R17-20260916","first-page":"659","article-title":"Detection of tones in low-noise noise: Further evidence for the role of envelope fluctuations.","volume":"83","author":"Kohlrausch","year":"1997","journal-title":"Acta Acust United With Acust"},{"key":"R18-20260916","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1121\/1.4941451","article-title":"Pulse-spreading harmonic complex as an alternative carrier for vocoder simulations of cochlear implants.","volume":"139","author":"Mesnildrey","year":"2016","journal-title":"J Acoust Soc Am"},{"key":"R19-20260916","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1080\/14992020902725521","article-title":"Polish sentence tests for measuring the intelligibility of speech in interfering noise.","volume":"48","author":"Ozimek","year":"2009","journal-title":"Int J Audiol"},{"key":"R21-20260916","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1097\/MAO.0000000000001821","article-title":"The sound of a cochlear implant investigated in patients with single-sided deafness and a cochlear implant.","volume":"39","author":"Peters","year":"2018","journal-title":"Otol Neurotol"},{"key":"R22-20260916","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1109\/TAU.1969.1162058","article-title":"IEEE recommended practice for speech quality measurements.","volume":"17","author":"Rothauser","year":"1969","journal-title":"IEEE Trans Audio Electroacoust"},{"key":"R23-20260916","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1097\/AUD.0000000000001641","article-title":"A level-adjusted cochlear frequency-to-place map for estimating tonotopic frequency mismatch with a cochlear implant.","volume":"46","author":"Sagi","year":"2025","journal-title":"Ear Hear"},{"key":"R24-20260916","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1126\/science.270.5234.303","article-title":"Speech recognition with primarily temporal cues.","volume":"270","author":"Shannon","year":"1995","journal-title":"Science"},{"key":"R25-20260916","doi-asserted-by":"crossref","first-page":"24056","DOI":"10.1038\/s41598-024-73173-6","article-title":"Employing deep learning model to evaluate speech information in acoustic simulations of cochlear implants.","volume":"14","author":"Sinha","year":"2024","journal-title":"Sci Rep"},{"key":"R26-20260916","doi-asserted-by":"crossref","first-page":"350","DOI":"10.3766\/jaaa.17.5.5","article-title":"Evaluation of equivalency in two recordings of monosyllabic words.","volume":"17","author":"Skinner","year":"2006","journal-title":"J Am Acad Audiol"},{"key":"R27-20260916","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1121\/1.3158835","article-title":"Effects of envelope bandwidth on the intelligibility of sine- and noise-vocoded speech.","volume":"126","author":"Souza","year":"2009","journal-title":"J Acoust Soc Am"},{"key":"R28-20260916","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1097\/AUD.0b013e31822c2549","article-title":"Development and validation of the AzBio sentence lists.","volume":"33","author":"Spahr","year":"2012","journal-title":"Ear Hear"},{"key":"R30-20260916","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1007\/s10162-007-0076-9","article-title":"Frequency map for the human cochlear spiral ganglion: Implications for cochlear implants.","volume":"8","author":"Stakhovskaya","year":"2007","journal-title":"J Assoc Res Otolaryngol"},{"key":"R31-20260916","doi-asserted-by":"crossref","first-page":"S2","DOI":"10.1097\/MAO.0000000000003373","article-title":"Valid acoustic models of cochlear implants: One size does not fit all.","volume":"42","author":"Svirsky","year":"2021","journal-title":"Otol Neurotol"},{"key":"R32-20260916","first-page":"8629","article-title":"Validation of acoustic models of auditory neural prostheses.","volume":"2013","author":"Svirsky","year":"2013","journal-title":"Proc IEEE Int Conf Acoust Speech Signal Process"},{"key":"R33-20260916","doi-asserted-by":"crossref","first-page":"354","DOI":"10.3109\/00016489.2014.1002052","article-title":"Bilateral cochlear implants with large asymmetries in electrode insertion depth: implications for the study of auditory plasticity.","volume":"135","author":"Svirsky","year":"2015","journal-title":"Acta Otolaryngol"},{"key":"R34-20260916","doi-asserted-by":"crossref","first-page":"57S","DOI":"10.1097\/00003446-200508001-00008","article-title":"Genetic algorithms for adaptive psychophysical procedures: Recipient-directed design of speech-processor MAPs.","volume":"26","author":"Wakefield","year":"2005","journal-title":"Ear Hear"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/AUD.0000000000001892","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T15:01:43Z","timestamp":1789570903000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/AUD.0000000000001892"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,16]]},"references-count":31,"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001892","relation":{},"ISSN":["0196-0202","1538-4667"],"issn-type":[{"value":"0196-0202","type":"print"},{"value":"1538-4667","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,16]]}}}