{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T00:30:21Z","timestamp":1770337821421,"version":"3.49.0"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Needle arthroscopy is a minimally invasive technique available for the management of common foot and ankle pathologies. Owing to the limitations associated with first-generation needle arthroscopic models, specifically visualization and fluid management, needle arthroscopy has undergone revitalization over the past decade. Newer systems are now using chip on tip visualization capability as well as improved fluid pumps allowing for direct intervention under improved visualization. The smaller diameter of the needle arthroscope permits procedures to be conducted in both the operating room and office setting under wide-awake conditions. We present this review to detail the history of needle arthroscopy and highlight how needle arthroscopy has improved care for patients with foot and ankle disorders.<\/jats:p>","DOI":"10.1097\/bh9.0000000000000013","type":"journal-article","created":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T21:00:37Z","timestamp":1770238837000},"page":"73-76","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Needle arthroscopy for the management of foot and ankle pathology"],"prefix":"10.1097","volume":"83","author":[{"given":"John F.","family":"Dankert","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James J.","family":"Butler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymond","family":"Walls","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John G.","family":"Kennedy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,12,1]]},"reference":[{"key":"R1-20260205","first-page":"23","article-title":"The evolution of arthroscopy a historical perspective","volume":"79","author":"Kouk","year":"2021","journal-title":"Bull Hosp Jt Dis"},{"key":"R2-20260205","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1053\/jars.2001.24058","article-title":"Severin Nordentoft: the first arthroscopist","volume":"17","author":"Kieser","year":"2001","journal-title":"Arthroscopy"},{"key":"R3-20260205","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.arthro.2009.10.005","article-title":"A history of arthroscopy","volume":"26","author":"Jackson","year":"2010","journal-title":"Arthroscopy"},{"key":"R4-20260205","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/S0749-8063(05)80057-X","article-title":"Comparison of \u201ccatheter\u201d and conventional arthroscopy in the diagnosis of knee derangements","volume":"10","author":"Denti","year":"1994","journal-title":"Arthroscopy"},{"key":"R5-20260205","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1093\/rheumatology\/keaa560","article-title":"Arthroscopy in rheumatology: where have we been? Where might we go?","volume":"60","author":"Ike","year":"2021","journal-title":"Rheumatology (Oxford)"},{"key":"R6-20260205","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/0749-8063(92)90062-G","article-title":"Office arthroscopy: a diagnostic alternative","volume":"8","author":"Halbrecht","year":"1992","journal-title":"Arthroscopy"},{"key":"R7-20260205","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1177\/036354659602400618","article-title":"Comparison of an optical catheter office arthroscope with a standard rigid rod-lens arthroscope in the evaluation of the knee","volume":"24","author":"Meister","year":"1996","journal-title":"Am J Sports Med"},{"key":"R8-20260205","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/00124743-199504000-00008","article-title":"Synovial biopsy of the knee joint under direct visualization by needle arthroscopy","volume":"1","author":"Moreland","year":"1995","journal-title":"J Clin Rheumatol"},{"key":"R9-20260205","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1002\/art.1780361005","article-title":"Detection of intraarticular abnormalities in osteoarthritis of the knee. A pilot study comparing needle arthroscopy with standard arthroscopy","volume":"36","author":"Ike","year":"1993","journal-title":"Arthritis Rheum"},{"key":"R14-20260205","first-page":"e23.00124","article-title":"In-office needle arthroscopy: indications, surgical techniques, tips, and tricks","volume":"8","author":"Gianakos","year":"2024","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"R15-20260205","first-page":"Clinical03","article-title":"Advancing techniques in foot and ankle arthroscopy: adopt needle arthroscopy in various sites of care","volume":"20","author":"Gianakos","year":"2023","journal-title":"AAOS Now"},{"key":"R16-20260205","doi-asserted-by":"crossref","first-page":"3080","DOI":"10.1007\/s00167-020-05889-7","article-title":"Two-millimetre diameter operative arthroscopy of the ankle is safe and effective","volume":"28","author":"Stornebrink","year":"2020","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R17-20260205","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1007\/s00167-014-3237-5","article-title":"Iatrogenic articular cartilage injuries during ankle arthroscopy","volume":"24","author":"Vega","year":"2016","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R18-20260205","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1177\/1071100719895504","article-title":"2-Mm diameter operative tendoscopy of the tibialis posterior, peroneal, and achilles tendons: a cadaveric study","volume":"41","author":"Stornebrink","year":"2020","journal-title":"Foot Ankle Int"},{"key":"R19-20260205","doi-asserted-by":"crossref","first-page":"e273","DOI":"10.1016\/j.eats.2021.10.018","article-title":"Posterior hindfoot needle endoscopy in the office setting","volume":"11","author":"Chen","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R20-20260205","doi-asserted-by":"crossref","first-page":"e327","DOI":"10.1016\/j.eats.2021.10.025","article-title":"In-office needle arthroscopy for anterior ankle impingement","volume":"11","author":"Colasanti","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R21-20260205","doi-asserted-by":"crossref","first-page":"e339","DOI":"10.1016\/j.eats.2021.10.027","article-title":"In-office needle tendoscopy of the tibialis posterior tendon with concomitant intervention","volume":"11","author":"Dankert","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R22-20260205","doi-asserted-by":"crossref","first-page":"e365","DOI":"10.1016\/j.eats.2021.11.002","article-title":"In-office needle tendoscopy of the peroneal tendons","volume":"11","author":"Kanakamedala","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R23-20260205","doi-asserted-by":"crossref","first-page":"e385","DOI":"10.1016\/j.eats.2021.11.005","article-title":"Needle arthroscopy cheilectomy for hallux rigidus in the office setting","volume":"11","author":"Kaplan","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R24-20260205","doi-asserted-by":"crossref","first-page":"e315","DOI":"10.1016\/j.eats.2021.10.024","article-title":"Achilles paratenon needle tendoscopy in the office setting","volume":"11","author":"Mercer","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R25-20260205","doi-asserted-by":"crossref","first-page":"e1015","DOI":"10.1016\/j.eats.2023.02.041","article-title":"Needle arthroscopy for osteochondral lesions of the first metatarsophalangeal joint: a standardized approach","volume":"12","author":"Walinga","year":"2023","journal-title":"Arthrosc Tech"},{"key":"R26-20260205","doi-asserted-by":"crossref","first-page":"e2343","DOI":"10.1016\/j.eats.2023.08.004","article-title":"Implantation of a cushioning injectable implant using needle arthroscopy in the foot and ankle and first carpometacarpal joint","volume":"12","author":"Stornebrink","year":"2023","journal-title":"Arthrosc Tech"},{"key":"R27-20260205","doi-asserted-by":"crossref","first-page":"e545","DOI":"10.1016\/j.eats.2021.12.005","article-title":"Anterior talofibular ligament augmentation with internal brace in the office setting","volume":"11","author":"Mercer","year":"2022","journal-title":"Arthrosc Tech"},{"key":"R28-20260205","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1016\/j.arthro.2021.09.016","article-title":"In-office needle arthroscopy for the treatment of anterior ankle impingement yields high patient satisfaction with high rates of return to work and sport","volume":"38","author":"Colasanti","year":"2022","journal-title":"Arthroscopy"},{"key":"R29-20260205","doi-asserted-by":"crossref","first-page":"e629","DOI":"10.1016\/j.asmr.2021.12.004","article-title":"Improved clinical outcomes and patient satisfaction of in-office needle arthroscopy for the treatment of posterior ankle impingement","volume":"4","author":"Mercer","year":"2022","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"R30-20260205","doi-asserted-by":"crossref","first-page":"100937","DOI":"10.1016\/j.asmr.2024.100937","article-title":"Excellent clinical outcomes and rapid return to activity following in-office needle tendoscopy for chronic achilles tendinopathy","volume":"6","author":"Butler","year":"2024","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"R31-20260205","first-page":"252","article-title":"In-office diagnostic needle arthroscopy: understanding the potential value for the US healthcare system","volume":"46","author":"McMillan","year":"2017","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"R32-20260205","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.arthro.2018.09.030","article-title":"Cost-effectiveness analysis of needle arthroscopy versus magnetic resonance imaging in the diagnosis and treatment of meniscal tears of the knee","volume":"35","author":"Amin","year":"2019","journal-title":"Arthroscopy"},{"key":"R33-20260205","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.knee.2023.03.009","article-title":"Moving orthopaedic procedures out of the operating theatre: outpatient needle arthroscopy can reduce cost and waste, and increase inpatient capacity compared to conventional knee arthroscopy","volume":"42","author":"Munn","year":"2023","journal-title":"Knee"}],"container-title":["Bulletin of the Hospital for Joint Diseases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/bh9.0000000000000013","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T12:00:20Z","timestamp":1770292820000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/bh9.0000000000000013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/bh9.0000000000000013","relation":{},"ISSN":["2328-5273"],"issn-type":[{"value":"2328-5273","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12]]}}}