{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T14:24:15Z","timestamp":1793283855345,"version":"4.5.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,10]]},"DOI":"10.1097\/bot.0000000000000315","type":"journal-article","created":{"date-parts":[[2015,2,25]],"date-time":"2015-02-25T21:55:55Z","timestamp":1424901355000},"page":"447-450","source":"Crossref","is-referenced-by-count":37,"title":["Dynamic Locked Plating of Distal Femur Fractures"],"prefix":"10.1097","volume":"29","author":[{"given":"Michael S.","family":"Linn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher M.","family":"McAndrew","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beth","family":"Prusaczyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olubusola","family":"Brimmo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William M.","family":"Ricci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Gardner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-3-20210212","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology.","volume":"84","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br"},{"issue":"suppl 2","key":"R2-3-20210212","doi-asserted-by":"crossref","first-page":"B1","DOI":"10.1016\/j.injury.2003.09.018","article-title":"Backgrounds of the technology of internal fixators.","volume":"34","author":"Perren","year":"2003","journal-title":"Injury"},{"key":"R3-3-20210212","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1097\/00005131-199710000-00010","article-title":". Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate.","volume":"11","author":"Koval","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R4-3-20210212","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1007\/s11999-011-1870-6","article-title":". 2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures.","volume":"469","author":"Henderson","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"R5-3-20210212","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","article-title":". Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases.","volume":"28","author":"Ricci","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R6-3-20210212","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":". Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.","volume":"24","author":"Lujan","year":"2010","journal-title":"J Orthop Trauma"},{"key":"R7-3-20210212","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1097\/BOT.0b013e31819df775","article-title":". Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study.","volume":"23","author":"Gardner","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R8-3-20210212","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.injury.2010.02.022","article-title":". Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots.","volume":"41","author":"Gardner","year":"2010","journal-title":"Injury"},{"issue":"suppl 1","key":"R9-3-20210212","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1097\/BOT.0b013e3182070f2d","article-title":". Effects of near cortical slotted holes in locking plate constructs.","volume":"25","author":"Sellei","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"suppl 10","key":"R10-3-20210212","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":". Fracture and Dislocation Classification Compendium - 2007: Orthopaedic Trauma Association Classification, Database and Outcomes Committee.","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R11-3-20210212","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0021-9290(98)00153-5","article-title":"Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing.","volume":"32","author":"Claes","year":"1999","journal-title":"J Biomech"},{"issue":"suppl 2","key":"R12-3-20210212","doi-asserted-by":"crossref","first-page":"S54","DOI":"10.1007\/s00198-004-1763-6","article-title":". Fixation principles in metaphyseal bone-a patent based review.","volume":"16","author":"Curtis","year":"2005","journal-title":"Osteoporos Int"},{"key":"R13-3-20210212","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1097\/01.bot.0000438368.44077.04","article-title":". Dynamic fixation of distal femur fractures using far cortical locking screws: a prospective observational study.","volume":"28","author":"Bottlang","year":"2014","journal-title":"J Orthop Trauma"},{"issue":"suppl 1","key":"R14-3-20210212","first-page":"S8","article-title":"Fitzpatrick DC, et al..","volume":"25","author":"Henderson","year":"2011","journal-title":"Locking plates for distal femur fractures: is there a problem with fracture healing J Orthop Trauma"},{"key":"R15-3-20210212","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.injury.2013.10.042","article-title":". Predictive factors of distal femoral fracture nonunion after lateral locked plating: a retrospective multicenter case-control study of 283 fractures.","volume":"45","author":"Rodriguez","year":"2014","journal-title":"Injury"},{"key":"R16-3-20210212","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.2106\/JBJS.I.01111","article-title":". Far cortical locking can improve healing of fractures stabilized with locking plates.","volume":"92","author":"Bottlang","year":"2010","journal-title":"J Bone Joint Surg Am"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000000315","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,13]],"date-time":"2021-05-13T23:10:41Z","timestamp":1620947441000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201510000-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10]]},"references-count":16,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000315","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2015,10]]}}}