{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T02:27:11Z","timestamp":1775269631555,"version":"3.50.1"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,6]]},"DOI":"10.1097\/bot.0000000000000520","type":"journal-article","created":{"date-parts":[[2016,1,7]],"date-time":"2016-01-07T12:30:32Z","timestamp":1452169832000},"page":"e217-e222","source":"Crossref","is-referenced-by-count":12,"title":["Combined Percutaneous Iliosacral Screw Fixation With Sacroplasty Using Resorbable Calcium Phosphate Cement for Osteoporotic Pelvic Fractures Requiring Surgery"],"prefix":"10.1097","volume":"30","author":[{"given":"Cory A.","family":"Collinge","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brett D.","family":"Crist","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-16-20210212","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1093\/rheumatology\/38.1.90b","article-title":"Sacral insufficiency fractures as an unsuspected cause of low back pain","volume":"38","author":"Weber","year":"1999","journal-title":"Rheumatology (Oxford)"},{"key":"R2-16-20210212","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1093\/rheumatology\/37.7.789","article-title":"Sacral insufficiency fractures: an unsuspected cause of low back pain","volume":"37","author":"Dasgupta","year":"1998","journal-title":"Br J Rheumatol"},{"key":"R3-16-20210212","doi-asserted-by":"crossref","first-page":"166","DOI":"10.3340\/jkns.2008.44.3.166","article-title":"Sacral insufficiency fracture, usually overlooked cause of lumbosacral pain","volume":"44","author":"Lee","year":"2008","journal-title":"J Korean Neurosurg Soc"},{"key":"R4-16-20210212","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1097\/00002060-200007000-00014","article-title":"The controversy surrounding sacral insufficiency fractures: to ambulate or not to ambulate?","volume":"79","author":"Babayev","year":"2000","journal-title":"Am J Phys Med Rehabil"},{"key":"R5-16-20210212","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s00256-009-0722-x","article-title":"Percutaneous treatment of insufficiency fractures: principles, technique and review of literature","volume":"39","author":"Beall","year":"2010","journal-title":"Skeletal Radiol"},{"key":"R6-16-20210212","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.3171\/foc.2005.18.3.8","article-title":"Balloon kyphoplasty for treatment of sacral insufficiency fractures. Report of three cases","volume":"18","author":"Deen","year":"2005","journal-title":"Neurosurg Focus"},{"key":"R7-16-20210212","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1097\/00005131-200008000-00002","article-title":"Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures","volume":"14","author":"Elder","year":"2000","journal-title":"J Orthop Trauma"},{"key":"R8-16-20210212","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.spinee.2007.05.011","article-title":"Percutaneous sacroplasty for osteoporotic sacral insufficiency fractures: a prospective, multicenter, observational pilot study","volume":"8","author":"Frey","year":"2008","journal-title":"Spine J"},{"key":"R9-16-20210212","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1097\/BRS.0b013e318074d4e1","article-title":"Efficacy and safety of percutaneous sacroplasty for painful osteoporotic sacral insufficiency fractures: a prospective, multicenter trial","volume":"32","author":"Frey","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R10-16-20210212","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1016\/S1051-0443(07)61976-9","article-title":"Sacroplasty: a new treatment for sacral insufficiency fracture","volume":"13","author":"Garant","year":"2002","journal-title":"J Vasc Interv Radiol"},{"key":"R11-16-20210212","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1016\/j.crad.2007.04.017","article-title":"CT-guided sacroplasty for the treatment of sacral insufficiency fractures","volume":"62","author":"Heron","year":"2007","journal-title":"Clin Radiol"},{"key":"R12-16-20210212","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.3174\/ajnr.A0665","article-title":"CT fluoroscopically guided percutaneous placement of transiliosacral rod for sacral insufficiency fracture: case report and technique","volume":"28","author":"Sciubba","year":"2007","journal-title":"AJNR Am J Neuroradiol"},{"key":"R13-16-20210212","doi-asserted-by":"crossref","first-page":"1650","DOI":"10.1302\/0301-620X.89B12.19058","article-title":"Percutaneous screw fixation for sacral insufficiency fractures: a review of three cases","volume":"89","author":"Tsiridis","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"R14-16-20210212","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1097\/BRS.0b013e318175c25c","article-title":"Computer assisted percutaneous placement of augmented iliosacral screws: a reasonable alternative to sacroplasty","volume":"33","author":"Tjardes","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R15-16-20210212","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s001980050155","article-title":"Lifestyle and biologic contributors to proximal femur bone mineral density and hip axis length in two distinct ethnic groups of premenopausal women","volume":"9","author":"Alekel","year":"1999","journal-title":"Osteoporos Int"},{"key":"R16-16-20210212","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1136\/bjsm.31.4.264","article-title":"A physically active lifestyle\u2013public health's best buy?","volume":"31","author":"Van Mechelen","year":"1997","journal-title":"Br J Sports Med"},{"key":"R17-16-20210212","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.jbspin.2008.01.024","article-title":"Outcome of osteoporotic pelvic fractures: an underestimated severity. Survey of 60 cases","volume":"75","author":"Breuil","year":"2008","journal-title":"Joint Bone Spine"},{"key":"R18-16-20210212","first-page":"139","article-title":"Prognosis of acute pelvic fractures in elderly patients: retrospective study","volume":"7","author":"Leung","year":"2001","journal-title":"Hong Kong Med J"},{"key":"R19-16-20210212","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1097\/00005131-199711000-00007","article-title":"Iliosacral screw fixation: early complications of the percutaneous technique","volume":"11","author":"Routt","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R20-16-20210212","doi-asserted-by":"crossref","first-page":"SA45","DOI":"10.1016\/S0020-1383(01)00060-2","article-title":"Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum","volume":"32","author":"Starr","year":"2001","journal-title":"Injury"},{"key":"R21-16-20210212","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/00005131-200307000-00001","article-title":"Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure?","volume":"17","author":"Griffin","year":"2003","journal-title":"J Orthop Trauma"},{"key":"R22-16-20210212","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/BOT.0b013e318162ab6e","article-title":"Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure?","volume":"22","author":"Starr","year":"2008","journal-title":"J Orthop Trauma"},{"key":"R23-16-20210212","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/00005131-200202000-00008","article-title":"Percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess \u201clateral compression type II\u201d pelvic fractures)","volume":"16","author":"Starr","year":"2002","journal-title":"J Orthop Trauma"},{"key":"R24-16-20210212","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/BOT.0b013e318033093e","article-title":"Mechanical evaluation of fracture fixation augmented with tricalcium phosphate bone cement in a porous osteoporotic cancellous bone model","volume":"21","author":"Collinge","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R25-16-20210212","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/01.bsd.0000210115.94273.76","article-title":"Augmentation of a loosened sacral pedicle screw with percutaneous polymethylmethacrylate injection","volume":"19","author":"Yilmaz","year":"2006","journal-title":"J Spinal Disord Tech"},{"key":"R26-16-20210212","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.2106\/00004623-199808000-00004","article-title":"Biomechanical and histological evaluation of a calcium phosphate cement","volume":"80","author":"Frankenburg","year":"1998","journal-title":"J Bone Joint Surg Am"},{"key":"R27-16-20210212","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1007\/s00402-005-0069-2","article-title":"Trans-sacral fixation for failed posterior fixation of the pelvic ring","volume":"126","author":"Beaule","year":"2006","journal-title":"Arch Orthop Trauma Surg"},{"key":"R28-16-20210212","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.rcl.2008.04.010","article-title":"Imaging of metabolic bone disease","volume":"46","author":"Guglielmi","year":"2008","journal-title":"Radiol Clin N Am"},{"issue":"suppl 1","key":"R29-16-20210212","first-page":"v","article-title":"Orthopaedic trauma Association Committee for Coding and classification.","volume":"10","year":"1996","journal-title":"J Orthop Trauma"},{"key":"R30-16-20210212","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/00003086-198802000-00010","article-title":"Sacral fractures: an Important problem retrospective Analysis of 236 cases","volume":"227","author":"Denis","year":"1988","journal-title":"Clin Orthopaedics Related Research"},{"key":"R31-16-20210212","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1056\/NEJM196901232800405","article-title":"Skeletal renewal and metabolic bone disease","volume":"280","author":"Harris","year":"1969","journal-title":"N Engl J Med"},{"key":"R32-16-20210212","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/0267-6605(92)90054-W","article-title":"Comparison of bone screw holding strength in healthy bovine and osteoporotic human cancellous bone","volume":"9","author":"Turner","year":"1992","journal-title":"Clin Mater"},{"key":"R33-16-20210212","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.2214\/ajr.184.6.01841956","article-title":"Percutaneous sacroplasty for the treatment of sacral insufficiency fractures","volume":"184","author":"Butler","year":"2005","journal-title":"AJR Am J Roentgenol"},{"key":"R34-16-20210212","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1056\/NEJMoa0900563","article-title":"A randomized trial ofvertebroplasty for osteoporotic spinal fractures","volume":"361","author":"Kallmes","year":"2009","journal-title":"N Engl J Med"},{"key":"R35-16-20210212","doi-asserted-by":"crossref","first-page":"E392","DOI":"10.1097\/BRS.0b013e3181cb4fcd","article-title":"Biomechanical comparison of three methods of sacralfracture fixation in osteoporotic bone","volume":"35","author":"Mears","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R36-16-20210212","doi-asserted-by":"crossref","first-page":"E392","DOI":"10.1097\/BRS.0b013e31816f6a10","article-title":"Inferior vena cava syndrome following percutaneous vertebroplasty with polymethylmethacrylate","volume":"33","author":"Kao","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R37-16-20210212","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1007\/s00701-008-1503-3","article-title":"Intradural cement leakage: a rare complication of percutaneous vertebroplasty","volume":"150","author":"Sabuncuoglu","year":"2008","journal-title":"Acta Neurochir (Wien)"},{"key":"R38-16-20210212","first-page":"224","article-title":"Intraspinal leakage of bone cement after vertebroplasty: a report of 3 cases","volume":"27","author":"Teng","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"R39-16-20210212","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1097\/01.RVI.0000144757.14780.E0","article-title":"A review of complications associated with vertebroplasty and kyphoplasty as reported to the Food and Drug Administration medical device related web site","volume":"15","author":"Nussbaum","year":"2004","journal-title":"J Vasc Interv Radiol"},{"key":"R40-16-20210212","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","article-title":"Early results of percutaneous iliosacral screws placed with the patient in the supine position","volume":"9","author":"Routt","year":"1995","journal-title":"J Orthop Trauma"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000000520","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T03:02:01Z","timestamp":1654052521000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201606000-00016"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6]]},"references-count":40,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000520","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2016,6]]}}}