{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T11:02:17Z","timestamp":1794049337302,"version":"4.8.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,9]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Sacral fractures that result in spinopelvic dissociation are unstable injuries that are often treated surgically, with iliosacral screw fixation and\/or lumbopelvic fixation from L4 to the pelvis. Open lumbopelvic fixation allows for direct fracture reduction and immediate postoperative weight bearing, but is associated with a relatively high wound complication rate. Open surgery often takes several hours and can be associated with significant blood loss, and therefore may not be well tolerated physiologically in these patients who often have multiple injuries. We developed a percutaneous lumbopelvic reduction and fixation technique to address these issues.<\/jats:p>","DOI":"10.1097\/bot.0000000000000559","type":"journal-article","created":{"date-parts":[[2016,2,19]],"date-time":"2016-02-19T09:23:58Z","timestamp":1455873838000},"page":"e318-e324","source":"Crossref","is-referenced-by-count":95,"title":["Percutaneous Lumbopelvic Fixation for Reduction and Stabilization of Sacral Fractures With Spinopelvic Dissociation Patterns"],"prefix":"10.1097","volume":"30","author":[{"given":"Seth K.","family":"Williams","sequence":"first","affiliation":[{"name":"Department of Orthopedics and Rehabilitation, University of Wisconsin School of Medicine and Public Health, Madison, WI; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen M.","family":"Quinnan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, University of Miami Miller School of Medicine, Miami, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.1097\/01.bot.0000202392.24999.7c","article-title":"Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing","volume":"20","author":"Schildhauer","year":"2006","journal-title":"J Orthop Trauma."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/00005131-200608000-00001","article-title":"Decompression and lumbopelvic fixation for sacral fracture-dislocations with spino-pelvic dissociation","volume":"20","author":"Schildhauer","year":"2006","journal-title":"J Orthop Trauma."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1007\/s00586-011-2125-7","article-title":"Surgical management of U-shaped sacral fractures: a systematic review of current treatment strategies","volume":"21","author":"Konig","year":"2012","journal-title":"Eur Spine J."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"S80","DOI":"10.1097\/01.brs.0000217949.31762.be","article-title":"Complications associated with surgical stabilization of high-grade sacral fracture dislocations with spino-pelvic instability","volume":"31","author":"Bellabarba","year":"2006","journal-title":"Spine (Phila Pa 1976)."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/00024720-200206000-00005","article-title":"Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations","volume":"15","author":"Schildhauer","year":"2002","journal-title":"J Spinal Disord Tech."},{"key":"R6-20230828","first-page":"173685","article-title":"Percutaneous iliac screws for minimally invasive spinal deformity surgery","volume":"2012","author":"Wang","year":"2012","journal-title":"Minim Invasive Surg."},{"key":"R7-20230828","article-title":"Minimally invasive percutaneous iliac screws: initial 24 case experience with CT confirmation","author":"Wang","year":"2012","journal-title":"J Spinal Disord Tech."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"E17","DOI":"10.3171\/FOC\/2008\/25\/8\/E17","article-title":"Percutaneous iliac screw placement: description of a new minimally invasive technique","volume":"25","author":"Wang","year":"2008","journal-title":"Neurosurg Focus."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/00003086-198802000-00010","article-title":"Sacral fractures: an important problem. Retrospective analysis of 236 cases","volume":"227","author":"Denis","year":"1988","journal-title":"Clin Orthop Relat Res."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1097\/00007632-198511000-00011","article-title":"Transverse fracture of the upper sacrum. Suicidal jumper's fracture","volume":"10","author":"Roy-Camille","year":"1985","journal-title":"Spine (Phila Pa 1976)."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1097\/00005131-199105020-00014","article-title":"An unusual type of fracture in the upper sacrum","volume":"5","author":"Strange-Vognsen","year":"1991","journal-title":"J Orthop Trauma."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/00005131-200301000-00004","article-title":"Triangular osteosynthesis and iliosacral screw fixation for unstable sacral fractures: a cadaveric and biomechanical evaluation under cyclic loads","volume":"17","author":"Schildhauer","year":"2003","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201609000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:15:48Z","timestamp":1693203348000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201609000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":12,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000559","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9]]}}}