{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T13:09:31Z","timestamp":1769087371703,"version":"3.49.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To assess the utility of the dorsal tangential view (DTV) in detecting intraoperative dorsal screw penetration in distal radius fractures treated with volar locked plating.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Academic level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Skeletally mature patients where open reduction internal fixation with volar locked plating was the definitive treatment. A total of twenty-six patients were evaluated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Intraoperative anteroposterior, lateral, 20 degree tilted lateral, and DTVs were obtained through fluoroscopy in all wrists. Screw exchange and position by fluoroscopic view was recorded. A computed tomography (CT) was taken postoperatively to identify residual prominent screws.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measures:<\/jats:title>\n            <jats:p>Data points included frequency of screw exchange by standard fluoroscopic views, the DTV, and residual prominent screws detected by CT.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Eight constructs of thirty (27%) had prominent screws evident on the DTV but not seen on standard fluoroscopic analysis. CT identified 5 additional screws with \u22651 mm dorsal penetration not identified by the DTV. All except 1 screw was in the second dorsal wrist compartment. The DTV was 67% sensitive with a negative predictive value of 97%.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>It is risky and unnecessary to place bicortical screws in the distal part of a volar plate. Given that the DTV view was not sufficient to avoid dorsal screw prominence, distal screws should be intentionally 2\u20134 mm shorter than measured. Recent studies propose bicortical distal locking screws are not needed for sufficient construct stiffness in volar locked plating. We suggest caution when using this view to verify acceptable placement of screws in proximity to the second dorsal compartment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Diagnostic level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000000661","type":"journal-article","created":{"date-parts":[[2016,7,28]],"date-time":"2016-07-28T00:06:07Z","timestamp":1469664367000},"page":"618-621","source":"Crossref","is-referenced-by-count":15,"title":["The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography"],"prefix":"10.1097","volume":"30","author":[{"given":"Devin","family":"Ganesh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ben","family":"Service","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Zirgibel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth","family":"Koval","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate","volume":"21","author":"Arora","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1302\/0301-620X.88B12.17696","article-title":"Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures","volume":"88","author":"Al-rashid","year":"2006","journal-title":"J Bone Joint Surg Br."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1097\/BOT.0b013e3182913fc5","article-title":"Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events","volume":"27","author":"Tarallo","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s11552-010-9316-2","article-title":"Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating","volume":"6","author":"Ozer","year":"2011","journal-title":"Hand (N Y)"},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/j.jhsa.2012.02.026","article-title":"Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius","volume":"37","author":"Ozer","year":"2012","journal-title":"J Hand Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.2106\/JBJS.H.01199","article-title":"Radiation exposure from musculoskeletal computerized tomographic scans","volume":"91","author":"Biswas","year":"2009","journal-title":"J Bone Joint Surg Am."},{"issue":"suppl 10","key":"R7-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u20142007: orthopaedic trauma association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R8-20230828","article-title":"The distal radius skyline view: validation of a new technique for determining dorsal screw penetration in locked volar plating of the distal radius","author":"Granville-Chapman"},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"e408","DOI":"10.1097\/BOT.0000000000000361","article-title":"Dorsal screw penetration with the use of volar plating of distal radius fractures: how can you best detect?","volume":"29","author":"Hill","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/s11552-007-9038-2","article-title":"Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study","volume":"2","author":"Maschke","year":"2007","journal-title":"Hand (N Y)"},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.jhsa.2004.04.006","article-title":"The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures","volume":"29","author":"Smith","year":"2004","journal-title":"J Hand Surg Am."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.jhsa.2011.07.020","article-title":"The dorsal horizon view: detecting screw protrusion at the distal radius","volume":"36","author":"Joseph","year":"2011","journal-title":"J Hand Surg Am."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jhsa.2014.10.021","article-title":"The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures","volume":"40","author":"Brunner","year":"2015","journal-title":"J Hand Surg Am."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1308\/003588411X561963","article-title":"Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study","volume":"93","author":"Hacker","year":"2011","journal-title":"Ann R Coll Surg Engl."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1097\/BOT.0b013e318225ea46","article-title":"Volar fixed-angle plating of distal radius fractures: screws versus pegs\u2013a biomechanical study in a cadaveric model","volume":"26","author":"Mehling","year":"2012","journal-title":"J Orthop Trauma."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jhsa.2011.12.013","article-title":"The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates","volume":"37","author":"Wall","year":"2012","journal-title":"J Hand Surg Am."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/BOT.0b013e31819b24e9","article-title":"A comparative study of clinical and radiologic outcomes of unstable colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating","volume":"23","author":"Arora","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"S116","DOI":"10.1097\/BOT.0b013e318162ab0b","article-title":"A representative case of osteoporotic distal radius fracture","volume":"22","author":"Arora","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1097\/BOT.0b013e318180db09","article-title":"Volar plate fixation of AO type C2 and C3 distal radius fractures, a single-center study of 55 patients","volume":"22","author":"Gruber","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1097\/BOT.0b013e3181d7a3a6","article-title":"Biomechanical comparison of locking versus nonlocking volar and dorsal T-plates for fixation of dorsally comminuted distal radius fractures","volume":"25","author":"Gondusky","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1097\/BOT.0b013e3182793df7","article-title":"Comparison of a new intramedullary scaffold to volar plating for treatment of distal radius fractures","volume":"27","author":"van Kampen","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/BOT.0b013e3182539333","article-title":"The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures","volume":"27","author":"Hershman","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1097\/BOT.0b013e3182008c83","article-title":"Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis","volume":"25","author":"Zenke","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/BOT.0000000000000519","article-title":"Volar locking plate or external fixation with optional addition of K-Wires for dorsally displaced distal radius fractures: a randomized controlled study","volume":"30","author":"Mellstrand","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R25-20230828","first-page":"369","article-title":"Cadaveric study of appropriate screw length for distal radius stabilization using volar plate fixation","volume":"44","author":"Austin","year":"2015","journal-title":"Am J Orthop."},{"key":"R26-20230828","article-title":"\u201cPrinciples of fluoroscopy.\u201d flouroscopic Module. Surgical skills task force of the american board of orthopaedic surgery","author":"Marsh","year":"2013"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201611000-00008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:38:01Z","timestamp":1693204681000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201611000-00008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000661","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]}}}