{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T03:55:14Z","timestamp":1781582114210,"version":"3.54.5"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Intramedullary nail and plate combination techniques have been described mostly for use in the proximal tibia. However, the nail and plate combination technique can also be used in the distal tibia, to counteract the deforming forces that cause construct failure and nonunion. In this article, we review pertinent anatomy and biomechanics and offer case examples that highlight the indications and applications of the nail and plate combination technique for distal tibia fractures.<\/jats:p>","DOI":"10.1097\/bot.0000000000000698","type":"journal-article","created":{"date-parts":[[2016,10,22]],"date-time":"2016-10-22T11:53:44Z","timestamp":1477137224000},"page":"S17-S21","source":"Crossref","is-referenced-by-count":23,"title":["Intramedullary Nail and Plate Combination Fixation for Complex Distal Tibia Fractures: When and How?"],"prefix":"10.1097","volume":"30","author":[{"given":"Richard S.","family":"Yoon","sequence":"first","affiliation":[{"name":"Division of Orthopaedic Trauma and Complex Adult Reconstruction, Department of Orthopaedic Surgery, Orlando Regional Medical Center, Orlando, FL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank A.","family":"Liporace","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.ocl.2014.04.001","article-title":"Techniques for the surgical treatment of distal tibia fractures","volume":"45","author":"Richard","year":"2014","journal-title":"Orthop Clin North Am."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/j.injury.2015.11.022","article-title":"The management of segmental tibial shaft fractures: a systematic review","volume":"47","author":"McMahon","year":"2016","journal-title":"Injury"},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"e169","DOI":"10.1097\/BOT.0000000000000530","article-title":"Metaphyseal distal tibia fractures: a cohort, single-surgeon study comparing outcomes of patients treated with minimally invasive plating versus intramedullary nailing","volume":"30","author":"Barcak","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"e277","DOI":"10.1097\/BOT.0000000000000299","article-title":"Intramedullary nailing and adjunct permanentplate fixation in complex tibia fractures","volume":"29","author":"Yoon","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/j.injury.2015.03.019","article-title":"Outcomes following combined intramedullary nail and plate fixation for complex tibia fractures: a multi-centre study","volume":"46","author":"Yoon","year":"2015","journal-title":"Injury"},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1097\/BOT.0b013e318213f709","article-title":"Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures","volume":"25","author":"Vallier","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R7-20230828","first-page":"1213","article-title":"Intramedullary nailing of distal metaphyseal tibial fractures","volume":"87","author":"Nork","year":"2005","journal-title":"J Bone Joint Surg Am."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/00003086-199607000-00029","article-title":"Semiextended position of intramedullary nailing of the proximal tibia","author":"Tornetta","year":"1996","journal-title":"Clin Orthop Relat Res."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/BOT.0b013e318250f041","article-title":"Problems, tricks, and pearls in intramedullary nailing of proximal third tibial fractures","volume":"27","author":"Liporace","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1302\/0301-620X.81B6.0810963","article-title":"The use of poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails","volume":"81","author":"Krettek","year":"1999","journal-title":"J Bone Joint Surg Br."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1097\/BOT.0b013e3181f6c001","article-title":"Suprapatellar versus infra-patellar intramedullary nail insertion of the tibia: a cadaveric model for comparison of patellofemoral contact pressures and forces","volume":"24","author":"Gelbke","year":"2010","journal-title":"J Orthop Trauma."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1097\/01.bot.0000244993.60374.d6","article-title":"Intramedullary nailing of proximal quarter tibial fractures","volume":"20","author":"Nork","year":"2006","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1097\/BOT.0b013e318185fa7e","article-title":"Operative treatment of ipsilateral noncontiguous unicondylar tibial plateau and shaft fractures: combining plates and nails","volume":"22","author":"Kubiak","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1097\/01.bot.0000153446.34484.70","article-title":"Provisional plating of type III open tibia fractures prior to intramedullary nailing","volume":"19","author":"Dunbar","year":"2005","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1302\/0301-620X.96B3.32185","article-title":"The influence of distal locking on the need for fibular plating in intramedullary nailing of distal metaphyseal tibiofibular fractures","volume":"96-B","author":"Attal","year":"2014","journal-title":"Bone Joint J."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/0020-1383(95)00228-6","article-title":"Intramedullary nail breakage in distal fractures of the tibia","volume":"27","author":"Hahn","year":"1996","journal-title":"Injury"},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/S0020-1383(00)00129-7","article-title":"Dia-metaphyseal distal tibial fractures\u2013treatment with a shortened intramedullary nail: a review of 15 cases","volume":"31","author":"Dogra","year":"2000","journal-title":"Injury"},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1007\/s00264-014-2294-1","article-title":"Treatment of distal tibial shaft fractures by three different surgical methods: a randomized, prospective study","volume":"38","author":"Li","year":"2014","journal-title":"Int Orthop."},{"issue":"suppl 4","key":"R19-20230828","doi-asserted-by":"crossref","first-page":"S99","DOI":"10.1016\/S0020-1383(15)30026-7","article-title":"Treatment of distal intraarticular tibial fractures: a biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis","volume":"46","author":"Kuhn","year":"2015","journal-title":"Injury"},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/0020-1383(95)00116-6","article-title":"A comparison of one versus two distal locking screws in tibial fractures treated with unreamed tibial nails: a prospective randomized clinical trial","volume":"27","author":"Kneifel","year":"1996","journal-title":"Injury"},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/BOT.0000000000000195","article-title":"Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing","volume":"29","author":"Chan","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1186\/s13018-015-0217-5","article-title":"Intramedullary nailing versus plating for distal tibia fractures without articular involvement: a meta-analysis","volume":"10","author":"Mao","year":"2015","journal-title":"J Orthop Surg Res."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.fas.2013.04.007","article-title":"Treatment of distal tibia metaphyseal fractures; plating versus intramedullary nailing: a systematic review of recent evidence","volume":"19","author":"Iqbal","year":"2013","journal-title":"Foot Ankle Surg."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.3928\/0147-7447-20041101-15","article-title":"Comparison of intramedullary nailing of distal third tibial shaft fractures: before and after traumatologists","volume":"27","author":"Obremskey","year":"2004","journal-title":"Orthopedics"},{"key":"R25-20230828","first-page":"64","article-title":"Proximal third tibial shaft fractures. Should they be nailed?","author":"Lang","year":"1995","journal-title":"Clin Orthop Relat Res."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1007\/s00264-011-1211-0","article-title":"Fibula-pro-tibia in plating tibial non-unions","volume":"35","author":"Said","year":"2011","journal-title":"Int Orthop."},{"issue":"suppl 1","key":"R27-20230828","first-page":"187","article-title":"The fibula pro tibia procedure in the treatment of nonunion of the tibia","volume":"58","author":"De Meulemeester","year":"1992","journal-title":"Acta Orthop Belg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201611001-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:02:11Z","timestamp":1693202531000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201611001-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000698","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]}}}