{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T22:25:37Z","timestamp":1789770337204,"version":"4.0.1"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,2]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allg\u00f6wer\u2013Donati or vertical mattress.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective, randomized.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 Academic Trauma Center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allg\u00f6wer\u2013Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA\/AO fracture classification.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Allg\u00f6wer\u2013Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allg\u00f6wer\u2013Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.0001). Mean perfusion impairment was less in the Allg\u00f6wer\u2013Donati cohort (12.8, SD = 9) compared with that in the vertical mattress cohort (23.4, SD = 14; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.03). One patient in each cohort experienced a wound complication.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The Allg\u00f6wer\u2013Donati suture technique offers improved incision perfusion compared with vertical mattress closure after open reduction internal fixation of ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000000731","type":"journal-article","created":{"date-parts":[[2016,10,14]],"date-time":"2016-10-14T10:25:47Z","timestamp":1476440747000},"page":"97-102","source":"Crossref","is-referenced-by-count":45,"title":["Allg\u00f6wer\u2013Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography"],"prefix":"10.1097","volume":"31","author":[{"given":"Steven F.","family":"Shannon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew T.","family":"Houdek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cody C.","family":"Wyles","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon J.","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William W.","family":"Cross","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph R.","family":"Cass","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen A.","family":"Sems","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: a review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury"},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1097\/00005131-199408000-00009","article-title":"Plain radiographic interpretation in trimalleolar ankle fractures poorly assesses posterior fragment size","volume":"8","author":"Ferries","year":"1994","journal-title":"J Orthop Trauma."},{"issue":"7 suppl","key":"R4-20230828","doi-asserted-by":"crossref","first-page":"261S","DOI":"10.1097\/01.prs.0000222582.84385.54","article-title":"Angiosomes of the foot and ankle and clinical implications for limb salvage: reconstruction, incisions, and revascularization","volume":"117","author":"Attinger","year":"2006","journal-title":"Plast Reconstr Surg."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.2106\/JBJS.H.00653","article-title":"Complication rates following open reduction and internal fixation of ankle fractures","volume":"91","author":"SooHoo","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.2106\/JBJS.K.01088","article-title":"Risk factors for wound complications after ankle fracture surgery","volume":"94","author":"Miller","year":"2012","journal-title":"J Bone Joint Surg Am."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1177\/107110070002100407","article-title":"Closed ankle fractures in the diabetic patient","volume":"21","author":"Flynn","year":"2000","journal-title":"Foot Ankle Int."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"837","DOI":"10.3928\/0147-7447-19970901-26","article-title":"Wound complications in total knee arthroplasty","volume":"20","author":"Dennis","year":"1997","journal-title":"Orthopedics"},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s11999-015-4209-x","article-title":"The Chitranjan Ranawat Award: running subcuticular closure enables the most robust perfusion after TKA: a randomized clinical trial","volume":"474","author":"Wyles","year":"2016","journal-title":"Clin Orthop Relat Res."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1097\/00000658-199111000-00011","article-title":"Tissue oxygenation, anemia, and perfusion in relation to wound healing in surgical patients","volume":"214","author":"Jonsson","year":"1991","journal-title":"Ann Surg."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/00003086-198401000-00015","article-title":"Factors influencing the incidence and outcome of infection following total joint arthroplasty","volume":"182","author":"Poss","year":"1984","journal-title":"Clin Orthop Relat Res."},{"issue":"4 suppl 1","key":"R12-20230828","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.arth.2007.03.014","article-title":"Wound complications after total knee arthroplasty","volume":"22","author":"Vince","year":"2007","journal-title":"J Arthroplasty."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1097\/BOT.0b013e318169074c","article-title":"The effect of suture pattern and tension on cutaneous blood flow as assessed by laser Doppler flowmetry in a pig model","volume":"22","author":"Sagi","year":"2008","journal-title":"J Orthop Trauma."},{"issue":"suppl 10","key":"R15-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u20142007: Orthopaedic Trauma Association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1086\/662016","article-title":"Improving risk-adjusted measures of surgical site infection for the national healthcare safety network","volume":"32","author":"Mu","year":"2011","journal-title":"Infect Control Hosp Epidemiol."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.ajic.2004.10.001","article-title":"National nosocomial infections surveillance (NNIS) system report, data summary from January 1992 through June 2004, issued October 2004","volume":"32","year":"2004","journal-title":"Am J Infect Control."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1007\/s00590-005-0043-2","article-title":"Closure of hip wound, clips or subcuticular sutures: does it make a difference?","volume":"16","author":"Singh","year":"2006","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1007\/s11999-009-0743-8","article-title":"Infection following operative treatment of ankle fractures","volume":"467","author":"Zalavras","year":"2009","journal-title":"Clin Orthop Relat Res."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1302\/0301-620X.91B6.21831","article-title":"Skin closure after total hip replacement: a randomized controlled trial of skin adhesive versus surgical staples","volume":"91-B","author":"Livesey","year":"2009","journal-title":"J Bone Joint Surg."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1177\/230949900401200210","article-title":"Comparing wound complication rates following closure of hip wounds with metallic skin staples or subcuticular vicryl suture: a prospective trial","volume":"12","author":"Shetty","year":"2004","journal-title":"J Orthop Surg."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/j.arth.2011.02.029","article-title":"A comparison of wound closure techniques for total knee arthroplasty","volume":"26","author":"Eggers","year":"2011","journal-title":"J Arthroplasty."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1302\/0301-620X.88B2.16923","article-title":"A comparison of three methods of wound closure following arthroplasty: a prospective randomized, controlled trial","volume":"88","author":"Kan","year":"2006","journal-title":"J Bone Joint Surg Br."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s10195-013-0282-7","article-title":"A prospective randomized comparison of two skin closure techniques in acetabular fracture surgery","volume":"15","author":"Mudd","year":"2014","journal-title":"J Orthop Traumatol."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201702000-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:20:22Z","timestamp":1693203622000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201702000-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":22,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000731","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2017,2]]}}}