{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:09:25Z","timestamp":1763017765162},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,6]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Compression techniques seem to be the primary factor in determining the success of both plating and nailing techniques for the management of acute fractures and for delayed and nonunion management of these fractures. An intramedullary nail that can provide continual compression (like a plate) and mechanical manipulation of the callous throughout the course of treatment is an ideal device that provides all the advantages of plating and nailing and avoids the noted limitations of both. The UNYTE compression humeral nail is based on the PRECICE intramedullary limb lengthening system. This nail provides the ability to intraoperatively compress a humeral fracture immediately and continue compression in the outpatient setting with the external remote controller. This compression nail allows the surgeon to continually modulate stability through controlled compression and the ability to relengthen if necessary. The capacity to achieve constant compression at the fracture site has demonstrated rapid healing of the \u201cat risk\u201d humerus fracture in this series. We review the current indications for use of this device after its early introduction. In most cases, this was the failure of conservative brace management that presented with a progressive distraction gap and minimal callous formation or those fractures that could not be adequately controlled in the brace with malalignment greater than 20 degrees. The protocol for intraoperative compression using the external remote controller is detailed, as is the outpatient protocol for follow-up. The compression algorithm for progression to full fracture healing is also reviewed.<\/jats:p>","DOI":"10.1097\/bot.0000000000000846","type":"journal-article","created":{"date-parts":[[2017,5,9]],"date-time":"2017-05-09T15:59:45Z","timestamp":1494345585000},"page":"S25-S28","source":"Crossref","is-referenced-by-count":14,"title":["Controlled Compression Nailing for At Risk Humeral Shaft Fractures"],"prefix":"10.1097","volume":"31","author":[{"given":"J. Tracy","family":"Watson","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Saint Louis University School of Medicine, St. Louis, MO; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roy W.","family":"Sanders","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Sports Medicine, USF Health Morsani College of Medicine."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"478","DOI":"10.2106\/00004623-200004000-00003","article-title":"Functional bracing for the treatment of fractures of the humeral diaphysis","volume":"82","author":"Sarmiento","year":"2000","journal-title":"J Bone Joint Surg Am."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1067\/mse.2002.121634","article-title":"The results of functional (Sarmiento) bracing of humeral shaft fractures","volume":"11","author":"Koch","year":"2002","journal-title":"J Shoulder Elbow Surg."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1097\/01.bot.0000246466.01287.04","article-title":"Outcome after closed functional treatment of humeral shaft fractures","volume":"20","author":"Ekholm","year":"2006","journal-title":"J Orthop Trauma."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/01.bot.0000249423.48074.82","article-title":"Treatment of diaphyseal fractures of the humerus using a functional brace","volume":"20","author":"Rutgers","year":"2006","journal-title":"J Orthop Trauma."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1007\/s00264-004-0612-8","article-title":"Functional treatment of closed humeral shaft fractures","volume":"29","author":"Toivanen","year":"2005","journal-title":"Int Orthop."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"596","DOI":"10.2106\/00004623-197759050-00004","article-title":"Functional bracing of fractures of the shaft of the humerus","volume":"59","author":"Sarmiento","year":"1977","journal-title":"J Bone Joint Surg Am."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.1016\/j.injury.2009.05.004","article-title":"Functional bracing of humeral shaft fractures: a review of clinical studies","volume":"41","author":"Papasoulis","year":"2010","journal-title":"Injury"},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.jse.2014.05.009","article-title":"Nonoperative treatment of humeral shaft fractures revisited","volume":"24","author":"Ali","year":"2015","journal-title":"J Shoulder Elbow Surg."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/00003086-198706000-00030","article-title":"Nonunion of the humeral shaft","volume":"219","author":"Healy","year":"1987","journal-title":"Clin Orthop Relat Res."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/BOT.0b013e31819b0bdc","article-title":"Proximal humeral nonunions treated with fixed-angle locked plating and an intramedullary strut allograft","volume":"23","author":"Badman","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.injury.2010.04.002","article-title":"Management of nonunions of the proximal humeral diaphysis","volume":"41","author":"Prasarn","year":"2010","journal-title":"Injury"},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/00013611-200312000-00008","article-title":"Endosteal allograft plating for the treatment of recalcitrant nonunions","volume":"18","author":"Cole","year":"2004","journal-title":"Tech Orthopaed."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"150","DOI":"10.4103\/0019-5413.108899","article-title":"Outcome of locking compression plates in humeral shaft nonunions","volume":"47","author":"Kumar","year":"2013","journal-title":"Indian J Orthop."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"2314","DOI":"10.1016\/j.injury.2015.09.041","article-title":"Union rate after operative treatment of humeral shaft nonunion\u2013A systematic review","volume":"46","author":"Peters","year":"2015","journal-title":"Injury"},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1007\/s00402-016-2418-8","article-title":"Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing","volume":"136","author":"Gessmann","year":"2016","journal-title":"Arch Orthop Trauma Surg."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1586\/17434440.2015.1005604","article-title":"PRECICE intramedullary limb lengthening system","volume":"12","author":"Paley","year":"2015","journal-title":"Expert Rev Med Devices."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201706001-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:02:01Z","timestamp":1693202521000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201706001-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000846","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6]]}}}