{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T07:33:31Z","timestamp":1791272011454,"version":"4.1.0"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,8]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>An extraarticular severely comminuted distal femoral fracture pattern (OTA\/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Using the same plate design, the study showed that implant material, screw type, and position of the plate affect the construct stiffness and fatigue life of the fixation construct. With this knowledge, the surgeon can decide the optimal construct based on a given fracture pattern, bone strength, and reduction quality.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000000860","type":"journal-article","created":{"date-parts":[[2017,4,8]],"date-time":"2017-04-08T02:51:09Z","timestamp":1491619869000},"page":"e241-e246","source":"Crossref","is-referenced-by-count":47,"title":["Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis"],"prefix":"10.1097","volume":"31","author":[{"given":"Utku","family":"Kandemir","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, University of California, San Francisco, San Francisco, CA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Augat","sequence":"additional","affiliation":[{"name":"Institute of Biomechanics, Paracelsus Medical University, Salzburg, Austria;"},{"name":"Institute of Biomechanics, Berufsgenossenschaftliche Unfallklinik, Murnau, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefanie","family":"Konowalczyk","sequence":"additional","affiliation":[{"name":"Stryker, Selzach, Switzerland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Wipf","sequence":"additional","affiliation":[{"name":"Stryker, Kiel, Germany; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geert","family":"von Oldenburg","sequence":"additional","affiliation":[{"name":"Stryker, Kiel, Germany; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulf","family":"Schmidt","sequence":"additional","affiliation":[{"name":"Department of Trauma Orthopaedic Surgery, Krankenhaus der Barmherzigen Schwestern Ried, Ried im Innkreis, Austria."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: a review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury"},{"issue":"Suppl 3","key":"R2-20230828","doi-asserted-by":"crossref","first-page":"C62","DOI":"10.1016\/S0020-1383(00)80034-0","article-title":"The epidemiology of fractures of the distal femur","volume":"31","author":"Martinet","year":"2000","journal-title":"Injury"},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1097\/00003086-198809000-00033","article-title":"Epidemiology of diaphyseal and distal femoral fractures in Rochester, Minnesota, 1965\u20131984","volume":"234","author":"Arneson","year":"1988","journal-title":"Clin Orthop Relat Res."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/BOT.0000000000000302","article-title":"Management of distal femur fractures with modern plates and nails: state of the art","volume":"29","author":"Beltran","year":"2015","journal-title":"J Orthop Trauma."},{"issue":"Suppl 3","key":"R5-20230828","doi-asserted-by":"crossref","first-page":"SC3","DOI":"10.1016\/S0020-1383(01)00179-6","article-title":"Distal femoral fractures: current treatment, results and problems","volume":"32","author":"Stover","year":"2001","journal-title":"Injury"},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1097\/01.ta.0000208129.10022.f8","article-title":"Biomechanical evaluation of the less invasive stabilization system and the 95 degree angled blade plate for the internal fixation of distal femur fractures in human cadaveric bones with high mineral density","volume":"60","author":"Zlowodzki","year":"2006","journal-title":"J Trauma."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"2808","DOI":"10.1007\/s11999-013-2867-0","article-title":"Implant material and design alter construct stiffness in distal femur locking plate fixation: a pilot study","volume":"471","author":"Schmidt","year":"2013","journal-title":"Clin Orthop Relat Res."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.ocl.2015.08.011","article-title":"Management of distal femur fractures in adults: an overview of options","volume":"47","author":"Gangavalli","year":"2016","journal-title":"Orthop Clin North Am."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"597","DOI":"10.5435\/00124635-201010000-00003","article-title":"Distal femoral fractures: current concepts","volume":"18","author":"Gwathmey","year":"2010","journal-title":"J Am Acad Orthop Surg."},{"issue":"Suppl 1","key":"R10-20230828","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1097\/BOT.0b013e3182070127","article-title":"Locking plates for distal femur fractures: is there a problem with fracture healing?","volume":"25","author":"Henderson","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1007\/s11999-011-1870-6","article-title":"2010 Mid-America Orthopaedic Association Physician in training award: healing complications are common after locked plating for distal femur fractures","volume":"469","author":"Henderson","year":"2011","journal-title":"Clin Orthop Relat Res."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":"Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation","volume":"24","author":"Lujan","year":"2010","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","article-title":"Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases","volume":"28","author":"Ricci","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.2106\/JBJS.I.01111","article-title":"Far cortical locking can improve healing of fractures stabilized with locking plates","volume":"92","author":"Bottlang","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"614","DOI":"10.2106\/JBJS.F.00510","article-title":"Results of polyaxial locked-plate fixation of periarticular fractures of the knee","volume":"89","author":"Haidukewych","year":"2007","journal-title":"J Bone Joint Surg Am."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1097\/BOT.0b013e31802bb372","article-title":"Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate","volume":"21","author":"Higgins","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/00005131-200103000-00008","article-title":"Improved intramedullary nail interlocking in osteoporotic bone","volume":"15","author":"Ito","year":"2001","journal-title":"J Orthop Trauma."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1097\/00005131-200008000-00004","article-title":"Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail","volume":"14","author":"Meyer","year":"2000","journal-title":"J Orthop Trauma."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/BOT.0b013e3181a567c8","article-title":"Biomechanical comparison of polyaxial-type locking plates and fixed-angle locking plates for internal fixation of distal femur fractures","volume":"23","author":"Otto","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/j.injury.2010.09.009","article-title":"Distal femur fractures of the elderly\u2014different treatment options in a biomechanical comparison","volume":"42","author":"W\u00e4hnert","year":"2011","journal-title":"Injury"},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.2106\/JBJS.H.01722","article-title":"Internal fixation of type-C distal femoral fractures in osteoporotic bone","volume":"92","author":"W\u00e4hnert","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00005131-200409000-00004","article-title":"Biomechanical evaluation of the less invasive stabilisation system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures","volume":"18","author":"Zlodowski","year":"2004","journal-title":"J Orthop Trauma."},{"issue":"Suppl 2","key":"R23-20230828","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1007\/s00198-004-1728-9","article-title":"Mechanics and mechanobiology of fracture healing in normal and osteoporotic bone","volume":"16","author":"Augat","year":"2005","journal-title":"Osteoporos Int."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.injury.2013.10.042","article-title":"Predictive factors of distal femoral fracture nonunion after lateral locked plating: a retrospective multicenter case-control study of 283 fractures","volume":"45","author":"Rodriguez","year":"2014","journal-title":"Injury"},{"key":"R25-20230828","first-page":"846","article-title":"Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases","volume":"88","author":"Vallier","year":"2006","journal-title":"J Bone Joint Surg Am."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/BOT.0b013e318234d460","article-title":"Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures","volume":"26","author":"Vallier","year":"2012","journal-title":"J Orthop Trauma."},{"issue":"Suppl 2","key":"R27-20230828","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP\u2014how can stability in locked internal fixators be controlled?","volume":"34","author":"Stoffel","year":"2003","journal-title":"Injury"},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1177\/0885328210367830","article-title":"Evaluation of a customized artificial osteoporotic bone model of the distal femur","volume":"26","author":"W\u00e4hnert","year":"2011","journal-title":"J Biomater Appl."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/S0883-5403(98)90009-2","article-title":"The forces in the distal femur and the knee during walking and other activities measured by telemetry","volume":"13","author":"Taylor","year":"1998","journal-title":"J Arthroplasty."},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1016\/S0020-1383(01)00044-4","article-title":"A new modular testing system for biomechanical evaluation of tibial intramedullary fixation devices","volume":"32","author":"Gaebler","year":"2001","journal-title":"Injury"},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/S0021-9290(97)00057-2","article-title":"Internal forces and moments in the femur during walking","volume":"30","author":"Duda","year":"1997","journal-title":"J Biomech."},{"key":"R33-20230828","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/S0021-9290(01)00042-2","article-title":"Forces and moments telemetered from two distal femoral replacements during various activities","volume":"34","author":"Taylor","year":"2001","journal-title":"J Biomech."},{"key":"R34-20230828","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1302\/0301-620X.96B1.31135","article-title":"Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures: a cadaver-based laboratory investigation","volume":"96-B","author":"Pekmezci","year":"2014","journal-title":"Bone Joint J."},{"key":"R35-20230828","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1097\/BOT.0b013e31818896b3","article-title":"Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison","volume":"22","author":"Wilkens","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R36-20230828","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1016\/S0736-0266(03)00098-6","article-title":"Shear movement at the fracture site delays healing in a diaphyseal fracture model","volume":"21","author":"Augat","year":"2003","journal-title":"J Orthop Res."},{"key":"R37-20230828","doi-asserted-by":"crossref","first-page":"752","DOI":"10.3928\/01477447-20100826-20","article-title":"The influence of fracture fixation biomechanics on fracture healing","volume":"33","author":"Hak","year":"2010","journal-title":"Orthopedics"},{"key":"R38-20230828","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br."},{"key":"R39-20230828","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/BOT.0000000000000593","article-title":"Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures","volume":"30","author":"Rodriguez","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R40-20230828","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1054\/arth.2002.34817","article-title":"Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty","volume":"17","author":"Bong","year":"2002","journal-title":"J Arthroplasty."},{"key":"R41-20230828","first-page":"695","article-title":"Construct stiffness of different fixation methods for supracondylar femoral fractures above total knee prostheses","volume":"29","author":"Cusick","year":"2000","journal-title":"Am J Orthop (Belle Mead NJ)."},{"key":"R42-20230828","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/00005131-199504000-00011","article-title":"Mechanics of retrograde nail versus plate fixation for supracondylar femur fractures","volume":"9","author":"Firoozbakhsh","year":"1995","journal-title":"J Orthop Trauma."},{"key":"R43-20230828","first-page":"443","article-title":"Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate","volume":"66","author":"Heiney","year":"2009","journal-title":"J Trauma."},{"key":"R44-20230828","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1097\/BOT.0b013e31806dd921","article-title":"Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability","volume":"21","author":"Stoffel","year":"2007","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201708000-00011","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T02:05:09Z","timestamp":1693188309000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201708000-00011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":43,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000860","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2017,8]]}}}