{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T17:19:07Z","timestamp":1781716747901,"version":"3.54.5"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,8]]},"abstract":"<jats:title>Summary:<\/jats:title><jats:p>Despite advances in the management of subtrochanteric fractures, in particular with the use of cephalomedullary nails, outcomes remain worse than other fractures of the proximal femur. Because an anatomic reduction is needed to offer the best results, several methods of reduction, using clamps and wires have been described. Reduction of fractures in elderly patients is especially complicated because of poor bone quality, comorbidities, and unfavorable fracture patterns. We describe a new technique of reduction and cerclage wiring through a mini-open approach for isolated subtrochanteric, as well as intertrochanteric fractures with extension into the subtrochanteric area, and report our results in a series of patients.<\/jats:p>","DOI":"10.1097\/bot.0000000000000871","type":"journal-article","created":{"date-parts":[[2017,4,28]],"date-time":"2017-04-28T12:47:27Z","timestamp":1493383647000},"page":"e263-e268","source":"Crossref","is-referenced-by-count":18,"title":["Cerclage Wiring Through a Mini-Open Approach to Assist Reduction of Subtrochanteric Fractures Treated With Cephalomedullary Fixation: Surgical Technique"],"prefix":"10.1097","volume":"31","author":[{"given":"Pablo","family":"Codesido","sequence":"first","affiliation":[{"name":"Department of Traumatology and Orthopaedic Surgery, Lucus Augusti University Hospital, Lugo, Spain; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana","family":"Mej\u00eda","sequence":"additional","affiliation":[{"name":"Department of Traumatology and Orthopaedic Surgery, Lucus Augusti University Hospital, Lugo, Spain; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Riego","sequence":"additional","affiliation":[{"name":"Department of Traumatology and Orthopaedic Surgery, Lucus Augusti University Hospital, Lugo, Spain; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina","family":"Ojeda-Thies","sequence":"additional","affiliation":[{"name":"Trauma Unit, Department of Traumatology and Orthopaedic Surgery, 12 de Octubre University Hospital, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"663","DOI":"10.5435\/00124635-200711000-00005","article-title":"Subtrochanteric femoral fractures","volume":"15","author":"Lundy","year":"2007","journal-title":"J Am Acad Orthop Surg."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.ocl.2004.05.006","article-title":"Subtrochanteric femur fractures","volume":"35","author":"Bedi","year":"2004","journal-title":"Orthop Clin North Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"1286","DOI":"10.1016\/j.injury.2007.05.013","article-title":"Outcome of traumatic subtrochanteric femoral fractures fixed using cephalo-medullary nails","volume":"38","author":"Shukla","year":"2007","journal-title":"Injury"},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/00005131-200006000-00003","article-title":"Intertrochanteric-subtrochanteric fractures: treatment with the long Gamma nail","volume":"14","author":"Barquet","year":"2000","journal-title":"J Orthop Trauma."},{"issue":"suppl 1 pt 2","key":"R5-20230828","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/JBJS.J.00158","article-title":"Clamp-assisted reduction of high subtrochanteric fractures of the femur: surgical technique","volume":"92","author":"Afsari","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1007\/s00198-009-0962-6","article-title":"Fragility fractures of the hip and femur: incidence and patient characteristics","volume":"21","author":"Nieves","year":"2010","journal-title":"Osteoporos Int."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/00003086-200402000-00030","article-title":"Nonunion of fractures of the subtrochanteric region of the femur","author":"Haidukewych","year":"2004","journal-title":"Clin Orthop Relat Res."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1007\/s00402-014-2023-7","article-title":"Percutaneous cerclage wiring followed by intramedullary nailing for subtrochanteric femoral fractures: a technical note with clinical results","volume":"134","author":"Kim","year":"2014","journal-title":"Arch Orthop Trauma Surg."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1016\/j.injury.2015.07.001","article-title":"Subtrochanteric fracture: the effect of cerclage wire on fracture reduction and outcome","volume":"46","author":"Hoskins","year":"2015","journal-title":"Injury"},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1097\/BOT.0b013e3181acfdfd","article-title":"Intramedullary versus extramedullary fixation for subtrochanteric femur fractures","volume":"23","author":"Kuzyk","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R11-20230828","first-page":"803","article-title":"Intramedullary versus extramedullary fixation in the management of subtrochanteric femur fractures: a meta-analysis","volume":"10","author":"Liu","year":"2015","journal-title":"Clin Interv Aging."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.injury.2012.12.010","article-title":"Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register","volume":"44","author":"Matre","year":"2013","journal-title":"Injury"},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"1910","DOI":"10.1016\/j.injury.2013.08.013","article-title":"Open reduction and intramedullary stabilisation of subtrochanteric femur fractures: a retrospective study of 56 cases","volume":"44","author":"Beingessner","year":"2013","journal-title":"Injury"},{"issue":"suppl 4","key":"R14-20230828","doi-asserted-by":"crossref","first-page":"S28","DOI":"10.1097\/BOT.0000000000000287","article-title":"Reducing subtrochanteric femur fractures: tips and tricks, do's and don'ts","volume":"29","author":"Yoon","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1097\/00005131-200407000-00003","article-title":"The treatment of subtrochanteric nonunions with the long gamma nail: twenty-six patients with a minimum 2-year follow-up","volume":"18","author":"Barquet","year":"2004","journal-title":"J Orthop Trauma."},{"issue":"suppl 1","key":"R16-20230828","doi-asserted-by":"crossref","first-page":"S76","DOI":"10.1016\/S0020-1383(13)70017-2","article-title":"Subtrochanteric fracture non-unions with implant failure managed with the \u201cDiamond\u201d concept","volume":"44","author":"Giannoudis","year":"2013","journal-title":"Injury"},{"key":"R17-20230828","first-page":"2217","article-title":"Trochanteric-entry long cephalomedullary nailing of subtrochanteric fractures caused by low-energy trauma","volume":"87","author":"Robinson","year":"2005","journal-title":"J Bone Joint Surg Am."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1016\/j.injury.2014.01.007","article-title":"The pointed clamp reduction technique for spiral subtrochanteric fractures: a technical note","volume":"45","author":"Yoon","year":"2014","journal-title":"Injury"},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"1913","DOI":"10.2106\/JBJS.H.01563","article-title":"Clamp-assisted reduction of high subtrochanteric fractures of the femur","volume":"91","author":"Afsari","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"e157","DOI":"10.1097\/BOT.0b013e31826fc03f","article-title":"Subtrochanteric fractures: treatment with cerclage wire and long intramedullary nail","volume":"27","author":"Tom\u00e1s","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.injury.2015.01.019","article-title":"Minimally invasive clamp-assisted reduction and cephalomedullary nailing without cerclage cables for subtrochanteric femur fractures in the elderly: surgical technique and results","volume":"46","author":"Mingo-Robinet","year":"2015","journal-title":"Injury"},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1016\/j.injury.2011.03.023","article-title":"Subtrochanteric hip fractures treated with cerclage cables and long cephalomedullary nails: a review of 17 consecutive cases over 2 years","volume":"42","author":"Kennedy","year":"2011","journal-title":"Injury"},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"240","DOI":"10.3109\/17453674.2012.665329","article-title":"Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures: 4 reoperations in 60 patients followed for 1 year","volume":"83","author":"Ban","year":"2012","journal-title":"Acta Orthop."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"581","DOI":"10.3928\/01477447-20090624-17","article-title":"Techniques of obtaining and maintaining reduction during nailing of femur fractures","volume":"32","author":"Riehl","year":"2009","journal-title":"Orthopedics"},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/s12306-015-0385-9","article-title":"A study of 44 patients with subtrochanteric fractures treated using long nail and cerclage cables","volume":"99","author":"Persiani","year":"2015","journal-title":"Musculoskelet Surg."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1159\/000329787","article-title":"Subtrochanteric fracture treatment: a retrospective study of 46 patients","volume":"20","author":"Li","year":"2011","journal-title":"Med Princ Pract."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1007\/s00264-010-1204-4","article-title":"The benefit of wire cerclage stabilisation of the medial hinge in intramedullary nailing for the treatment of subtrochanteric femoral fractures: a biomechanical study","volume":"35","author":"M\u00fcller","year":"2011","journal-title":"Int Orthop."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1302\/0301-620X.86B4.14097","article-title":"Factors affecting rates of infection and nonunion in intramedullary nailing","volume":"86","author":"Malik","year":"2004","journal-title":"J Bone Joint Surg Br."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"94","DOI":"10.5435\/00124635-201202000-00005","article-title":"Contributing factors to surgical site infections","volume":"20","author":"Harrop","year":"2012","journal-title":"J Am Acad Orthop Surg."},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J Bone Joint Surg Br."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.injury.2012.10.016","article-title":"Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study","volume":"44","author":"Apivatthakakul","year":"2013","journal-title":"Injury"},{"key":"R33-20230828","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1007\/s00590-011-0780-3","article-title":"Is there any purpose in classifying subtrochanteric fractures? The reproducibility of four classification systems","volume":"24","author":"Guyver","year":"2014","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R34-20230828","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.injury.2010.02.018","article-title":"Classification of subtrochanteric femoral fractures","volume":"41","author":"Loizou","year":"2010","journal-title":"Injury"},{"key":"R35-20230828","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.2106\/JBJS.G.01580","article-title":"Variability in the assessment of fracture-healing in orthopaedic trauma studies","volume":"90","author":"Corrales","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R36-20230828","first-page":"87","article-title":"Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures","author":"Baumgaertner","year":"1998","journal-title":"Clin Orthop."},{"key":"R37-20230828","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","article-title":"The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip","volume":"77","author":"Baumgaertner","year":"1995","journal-title":"J Bone Joint Surg Am."},{"key":"R38-20230828","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.arth.2004.12.050","article-title":"Femoral artery and vein injury after cerclage wiring of the femur: a case report","volume":"20","author":"Mehta","year":"2005","journal-title":"J Arthroplasty."},{"key":"R39-20230828","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1007\/s11999-007-0109-z","article-title":"Case report: superficial femoral artery injury resulting from cerclage wiring during revision THA","volume":"466","author":"Aleto","year":"2008","journal-title":"Clin Orthop."},{"key":"R40-20230828","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/0268-0033(90)90007-S","article-title":"Strength of cerclage fixation systems: a biomechanical study","volume":"5","author":"Incavo","year":"1990","journal-title":"Clin Biomech Bristol Avon."},{"key":"R41-20230828","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","article-title":"Biomechanical performance of different cable and wire cerclage configurations","volume":"37","author":"Lenz","year":"2013","journal-title":"Int Orthop."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201708000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,23]],"date-time":"2024-06-23T20:55:43Z","timestamp":1719176143000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201708000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":40,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000871","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2017,8]]}}}