{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T21:20:29Z","timestamp":1793654429355,"version":"4.5.1"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>This study aimed to compare clinical outcomes and radiographic findings between patients who received 2 different implants (smooth-stemmed modular implant or an anatomic press-fit implant) on patients with acute terrible triad injuries.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective cohort.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level II Trauma center, University hospital.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Thirty-four patients with an isolated terrible triad injury were divided into 2 study groups (n = 17 each) with different sets of radial head implants and followed for 2 years. A total of 14 patients in each group (n = 28) completed the study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Group 1 received a smooth-stemmed round modular monopolar implant. Group 2 received an in-growth modular monopolar press-fit anatomic implant.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Clinical outcomes were evaluated using the Visual Analog Scale, Mayo Index, and Disabilities of the Arm, Shoulder, and Hand (DASH) survey. Radiographs were evaluated for ectopic bone formation and loosening.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>No difference in clinical outcome when comparing range of motion and functionally scores between groups. Ectopic bone formation occurred equally with implants. Bone formation at the proximal radius under the implant occurred more in group 1 (85.7%), (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.046). Five press-fit stems had radiolucent lines at 2-year follow-up. Two were removed because of symptomatic loosening.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Short-term outcomes for both implants showed to be equally effective treatment options. The in vitro biomechanical advantages of anatomic implants do not translate into short-term improved outcomes. Symptomatic aseptic loosening in anatomic implants is common. Bone formation at the proximal radial neck was observed more with smooth-stemmed implants; further studies should assess this findings and clinical implication.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000000885","type":"journal-article","created":{"date-parts":[[2017,5,10]],"date-time":"2017-05-10T15:20:43Z","timestamp":1494429643000},"page":"503-509","source":"Crossref","is-referenced-by-count":19,"title":["Radial Head Ingrowth Anatomic Implant Versus Smooth Stem Monoblock Implant in Acute Terrible Triad Injury: A Prospective Comparative Study"],"prefix":"10.1097","volume":"31","author":[{"given":"David","family":"Rodriguez-Quintana","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Puerto Rico School of Medicine, San Juan, PR; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Beaton","family":"Comulada","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Puerto Rico School of Medicine, San Juan, PR; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natalie","family":"Rodriguez-Quintana","sequence":"additional","affiliation":[{"name":"School of Public Health, University of Puerto Rico School of Medicine, San Juan, PR."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Lopez-Gonzalez","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Puerto Rico School of Medicine, San Juan, PR; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","first-page":"109","article-title":"Results of treatment of fracture-dislocations of the elbow","author":"Broberg","year":"1987","journal-title":"Clin Orthop Relat Res."},{"issue":"suppl 1","key":"R2-20230828","first-page":"136","article-title":"Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. Surgical technique","volume":"87","author":"Bain","year":"2005","journal-title":"J Bone Jt Surg Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1016\/j.jse.2013.02.011","article-title":"Clinical and radiographic comparisons of two different radial head implant designs","volume":"22","author":"Berschback","year":"2013","journal-title":"J Shoulder Elbow Surg."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.jse.2004.05.009","article-title":"Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture: efficacy of prosthetic replacement and ligament repair","volume":"14","author":"Jensen","year":"2005","journal-title":"J Shoulder Elbow Surg."},{"key":"R5-20230828","first-page":"108","article-title":"Observations on the effect of movement on bone ingrowth into porous-surfaced implants","author":"Pilliar","year":"1986","journal-title":"Clin Orthop Relat Res."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1097\/BOT.0b013e318238b3a2","article-title":"The biomechanical effect of prosthetic design on radiocapitellar stability in a terrible triad model","volume":"26","author":"Chanlalit","year":"2012","journal-title":"J Orthop Trauma."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u20142007: Orthopaedic Trauma Association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.2106\/00004623-199072090-00012","article-title":"The lateral approach for operative release of post-traumatic contracture of the elbow","volume":"72","author":"Husband","year":"1990","journal-title":"J Bone Jt Surg Am."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jhsa.2005.06.012","article-title":"Reference points for radial head prosthesis size","volume":"31","author":"Doornberg","year":"2006","journal-title":"J Hand Surg."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"2629","DOI":"10.2106\/00004623-200412000-00007","article-title":"Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow","volume":"86-A","author":"Van Glabbeek","year":"2004","journal-title":"J Bone Jt Surg Am."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.2106\/00004623-198971090-00011","article-title":"Fractures of the coronoid process of the ulna","volume":"71","author":"Regan","year":"1989","journal-title":"J Bone Jt Surg Am."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"277","DOI":"10.2106\/JBJS.J.01744","article-title":"Upper extremity-specific measures of disability and outcomes in orthopaedic surgery","volume":"94","author":"Smith","year":"2012","journal-title":"J Bone Jt Surg Am."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"872","DOI":"10.2106\/00004623-198163060-00002","article-title":"A biomechanical study of normal functional elbow motion","volume":"63","author":"Morrey","year":"1981","journal-title":"J Bone Jt Surg Am."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"1336","DOI":"10.1016\/j.jse.2012.03.005","article-title":"Radial head reconstruction versus replacement in the treatment of terrible triad injuries of the elbow","volume":"21","author":"Leigh","year":"2012","journal-title":"J Shoulder Elbow Surg."},{"key":"R16-20230828","first-page":"2192","article-title":"Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes","volume":"88","author":"Grewal","year":"2006","journal-title":"J Bone Jt Surg Am."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.2106\/00004623-200705000-00021","article-title":"Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability","volume":"89","author":"Doornberg","year":"2007","journal-title":"J Bone Jt Surg Am."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.jse.2008.09.012","article-title":"Radiolucencies surrounding a smooth-stemmed radial head component may not correlate with forearm pain or poor elbow function","volume":"18","author":"Fehringer","year":"2009","journal-title":"J Shoulder Elbow Surg."},{"issue":"suppl 1","key":"R19-20230828","doi-asserted-by":"crossref","first-page":"S69","DOI":"10.1007\/s12306-012-0198-z","article-title":"Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up","volume":"96","author":"Rotini","year":"2012","journal-title":"Musculoskelet Surg."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/j.jse.2011.11.025","article-title":"Effect of stem length on prosthetic radial head micromotion","volume":"21","author":"Shukla","year":"2012","journal-title":"J Shoulder Elbow Surg."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1302\/0301-620X.94B6.28176","article-title":"Short- to mid-term results of metallic press-fit radial head arthroplasty in unstable injuries of the elbow","volume":"94","author":"Flinkkila","year":"2012","journal-title":"J Bone Jt Surg Br."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jse.2011.05.008","article-title":"Forearm pain associated with loose radial head prostheses","volume":"21","author":"O'Driscoll","year":"2012","journal-title":"J Shoulder Elbow Surg."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1016\/j.jse.2015.11.014","article-title":"Outcomes and radiographic findings of anatomic press-fit radial head arthroplasty","volume":"25","author":"Levy","year":"2016","journal-title":"J Shoulder Elbow Surg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201709000-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:51:40Z","timestamp":1693205500000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201709000-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000000885","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2017,9]]}}}