{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T08:53:53Z","timestamp":1760864033486},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Fixation of comminuted vertically unstable sacral fractures continues to be a surgical dilemma. Although triangular osteosynthesis is a good construct and resists vertical translation, complications still occur. Herein, we introduce a new biplanar fixation technique, using segmental spinal instrumentation as an alternative to triangular osteosynthesis. This technique is remarkably valuable in cases with sacral morphology and\/or complex fracture patterns that preclude safe percutaneous iliosacral screw insertion.<\/jats:p>","DOI":"10.1097\/bot.0000000000001101","type":"journal-article","created":{"date-parts":[[2018,1,10]],"date-time":"2018-01-10T07:03:26Z","timestamp":1515567806000},"page":"e185-e190","source":"Crossref","is-referenced-by-count":5,"title":["Biplanar Posterior Pelvic Fixator for Unstable Sacral Fractures: A New Fixation Technique"],"prefix":"10.1097","volume":"32","author":[{"given":"Mohamed","family":"Abo-Elsoud","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Said","family":"Eldeeb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Gobba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fouad Zamel","family":"Sadek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1302\/0301-620X.70B1.3276697","article-title":"Pelvic ring fractures: should they be fixed?","volume":"70","author":"Tile","year":"1988","journal-title":"J Bone Joint Surg Br."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"458","DOI":"10.5435\/JAAOS-21-08-458","article-title":"Pelvic fractures: part 2. Contemporary indications and techniques for definitive surgical management","volume":"21","author":"Langford","year":"2013","journal-title":"J Am Acad Orthop Surg."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"152","DOI":"10.5435\/00124635-199605000-00005","article-title":"Acute pelvic fractures: II. Principles of management","volume":"4","author":"Tile","year":"1996","journal-title":"J Am Acad Orthop Surg."},{"key":"R4-20230828","first-page":"949","article-title":"The impact of open reduction internal fixation on acute pain management in unstable pelvic ring injuries","volume":"68","author":"Barei","year":"2010","journal-title":"J Trauma"},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1097\/00003086-199608000-00022","article-title":"Outcome of operatively treated unstable posterior pelvic ring disruptions","volume":"329","author":"Tornetta","year":"1996","journal-title":"Clin Orthop Relat Res."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/00003086-199408000-00010","article-title":"The Hannover experience in management of pelvic fractures","volume":"305","author":"Pohlemann","year":"1994","journal-title":"Clin Orthop Relat Res."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/00005131-200307000-00001","article-title":"Vertically unstable pelvic fractures fixed with percutaneous ilio-sacral screws: does posterior injury pattern predict fixation failure?","volume":"17","author":"Griffin","year":"2003","journal-title":"J Orthop Trauma"},{"key":"R8-20230828","first-page":"39","article-title":"Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis","volume":"17","author":"Sal\u00e1\u0161ek","year":"2015","journal-title":"Acta Bioeng Biomech."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"41","DOI":"10.55095\/achot2015\/005","article-title":"Minimally invasive stabilization of posterior pelvic ring injuries with a transiliac internal fixator and two iliosacral screws: comparison of outcome","volume":"82","author":"Sal\u00e1\u0161ek","year":"2015","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"R10-20230828","first-page":"28","article-title":"Distraction spondylodesis of the sacrum in \u201cvertical shear lesions\u201d of the pelvis","volume":"97","author":"Kach","year":"1994","journal-title":"Unfallchirurg"},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1097\/00005131-199806000-00002","article-title":"The triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing","volume":"12","author":"Schildhauer","year":"1998","journal-title":"J Orthop Trauma"},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/BOT.0b013e3181a32b91","article-title":"A comprehensive analysis with minimum one-year follow-up of vertically unstable trans-foraminal sacral fractures treated with triangular osteosynthesis","volume":"23","author":"Sagi","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/00003086-199608000-00016","article-title":"Internal fixation of unstable pelvic ring injuries","volume":"329","author":"Matta","year":"1996","journal-title":"Clin Orthop Relat Res."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1302\/0301-620X.71B2.2925751","article-title":"Grading the outcome of pelvic fractures","volume":"71","author":"Majeed","year":"1989","journal-title":"J Bone Joint Surg Br."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/00003086-199602000-00028","article-title":"Internal fixation for the transforaminal sacral fracture","volume":"323","author":"Simonain","year":"1996","journal-title":"Clin Orthop."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.spinee.2017.03.023","article-title":"Morphometry of the sacrum and its implication on trans-sacral corridors using a computed tomography data-based three-dimensional statistical model","volume":"17","author":"Wagner","year":"2017","journal-title":"Spine J."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"8","DOI":"10.5435\/00124635-201201000-00002","article-title":"Variations in sacral morphology and implications for iliosacral screw fixation","volume":"20","author":"Miller","year":"2012","journal-title":"J Am Acad Orthop Surg."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.1016\/j.injury.2014.09.003","article-title":"Factors associated with outcome of spinopelvic dissociation treated with lumbopelvic fixation","volume":"45","author":"Lindahl","year":"2014","journal-title":"Injury"},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.injury.2012.05.003","article-title":"Lumbopelvic fixation for multiplanar sacral fractures with spinopelvic instability","volume":"43","author":"Tan","year":"2012","journal-title":"Injury"},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/00005131-200105000-00002","article-title":"Percutaneous stabilization of U-shaped sacral fractures using iliosacral screws: technique and early results","volume":"15","author":"Nork","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1302\/0301-620X.73B6.1955446","article-title":"Conservative management of transverse fractures of the sacrum with neurological features. A report of four cases","volume":"73","author":"Phelan","year":"1991","journal-title":"J Bone Joint Surg Br"},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1097\/BOT.0000000000000559","article-title":"Percutaneous lumbopelvic fixation for reduction and stabilization of sacral fractures with spinopelvic dissociation patterns","volume":"30","author":"Williams","year":"2016","journal-title":"J Orthop Trauma"},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/BOT.0b013e3181a32b91","article-title":"Schildhauer invited commentary on Sagi HC, Militano U, Caron T, et al. A comprehensive analysis with minimum one-year follow-up of vertically unstable transforaminal sacral fractures treated with triangular osteosynthesis","volume":"23","author":"Thomas","year":"2009","journal-title":"J Orthop Trauma"},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/00005131-200608000-00001","article-title":"Decompression and lumbopelvic fixation for sacral fracture-dislocations with spino-pelvic dissociation","volume":"20","author":"Schildhauer","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/00005131-200301000-00004","article-title":"Triangular osteosynthesis and iliosacral screw fixation in unstable sacrum fractures. A cadaveric and biomechanical evaluation under cyclic loads","volume":"17","author":"Schildhauer","year":"2003","journal-title":"J Orthop Trauma"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201805000-00016","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:13:43Z","timestamp":1693203223000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201805000-00016"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001101","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}