{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T15:41:02Z","timestamp":1783957262102,"version":"3.55.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To investigate the effect of blocking screws (BS) on the union rate and stability of infraisthmal femur fractures treated with retrograde intramedullary nail (RIMN) insertion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>A single level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>All patients with an infraisthmal femur fracture treated with a RIMN from 2005 to 2012 were included.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>All fractures were treated with a RIMN. BS were used at the discretion of the treating surgeon.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>(1) Radiographic time to union, (2) initial postoperative sagittal and coronal angulation, and (3) final sagittal and coronal angulation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Neither the average time to union (BS 21.1 weeks vs. 21.8 weeks), nor union rates (BS 61% vs. 77%) were statistically different between BS and non-BS constructs. No significant alignment differences existed whether BS were used or not.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>In this study, we were not able to verify our hypothesis. In fact, we did not find any significant advantages when BS were added to a RIMN construct for distal femur fractures with respect to union time, union rate, or improvements in alignment. Additional studies are needed to determine the actual benefit of BS in the treatment of infraisthmal femoral shaft fractures treated with retrograde intramedullary nailing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001119","type":"journal-article","created":{"date-parts":[[2018,1,21]],"date-time":"2018-01-21T02:55:12Z","timestamp":1516503312000},"page":"251-255","source":"Crossref","is-referenced-by-count":23,"title":["Effect of Blocking Screws on Union of Infraisthmal Femur Fractures Stabilized With a Retrograde Intramedullary Nail"],"prefix":"10.1097","volume":"32","author":[{"given":"Bryan","family":"Van Dyke","sequence":"first","affiliation":[{"name":"Ohio Health, Department of Orthopedic Surgery, Columbus, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Colley","sequence":"additional","affiliation":[{"name":"Ohio Health, Department of Orthopedic Surgery, Columbus, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Ottomeyer","sequence":"additional","affiliation":[{"name":"Ohio Health, Department of Orthopedic Surgery, Columbus, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Palmer","sequence":"additional","affiliation":[{"name":"OrthoNeuro, Columbus, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Pugh","sequence":"additional","affiliation":[{"name":"Ohio Health, Department of Orthopedic Surgery, Columbus, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1097\/00005131-200009000-00006","article-title":"Prospective comparison of retrograde and antegrade femoral intramedullary nailing","volume":"14","author":"Ostrum","journal-title":"J Orthop Trauma."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/00005131-199911000-00006","article-title":"The mechanical effect of blocking screws (\u201cPoller screws\u201d) in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails","volume":"13","author":"Krettek","year":"1999","journal-title":"J Orthop Trauma."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"296","DOI":"10.5435\/00124635-200905000-00004","article-title":"Intramedullary nailing of femoral shaft fractures: current concepts","volume":"17","author":"Ricci","year":"2009","journal-title":"J Am Acad Orthop Surg."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"209","DOI":"10.5435\/00124635-199907000-00001","article-title":"Retrograde nailing of the femoral shaft","volume":"7","author":"Moed","journal-title":"J Am Acad Orthop Surg."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00005131-200103000-00003","article-title":"Retrograde versus antegrade nailing of femoral shaft fractures","volume":"15","author":"Ricci","journal-title":"J Orthop Trauma."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1097\/00005131-200102000-00003","article-title":"Angular malalignment after intramedullary nailing of femoral shaft fractures","volume":"15","author":"Ricci","year":"2001","journal-title":"J Orthop Trauma."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/00005131-200408000-00002","article-title":"Rotational malalignment after intramedullary nailing of femoral fractures","volume":"18","author":"Jaarsma","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/BOT.0b013e3181ad61f2","article-title":"Distal third femur fractures treated with retrograde femoral nailing and blocking screws","volume":"23","author":"Ostrum","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"17","DOI":"10.2106\/00004623-200412002-00004","article-title":"The logic and clinical applications of blocking screws","author":"Stedtfeld","year":"2004","journal-title":"J Bone Joint Surg Am."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1302\/0301-620X.81B6.0810963","article-title":"The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails","volume":"81","author":"Krettek","year":"1999","journal-title":"J Bone Joint Surg Br."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00005131-200105000-00005","article-title":"Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws","volume":"15","author":"Ricci","year":"2001","journal-title":"J Orthop Trauma."},{"issue":"Supp 10","key":"R12-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u20142007: orthopaedic trauma association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"e936","DOI":"10.3928\/01477447-20130624-26","article-title":"Blocking screws for the treatment of distal femur fractures","volume":"36","author":"Seyhan","year":"2013","journal-title":"Orthopedics"},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1177\/230949901302100208","article-title":"Blocking screws: an adjunct to retrograde nailing for distal femoral shaft fractures","volume":"21","author":"Gavaskar","year":"2013","journal-title":"J Orthop Surg (Hong Kong)."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201805000-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:13:34Z","timestamp":1693203214000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201805000-00007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001119","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}