{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T06:44:55Z","timestamp":1793256295768,"version":"4.5.0"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To assess clinical and hospital quality outcomes of patients receiving the previously reported Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) imaging protocol.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective Chart review.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level I Trauma Center and affiliated Tertiary Care Hospital Center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Fifty patients who received this protocol for acute traumatic fracture evaluation and met the inclusion criteria were compared with a cohort of 50 patients matched for age and fracture type who previously received conventional CT scanning for acute traumatic fracture evaluation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) protocol for diagnostic fracture evaluation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measures:<\/jats:title>\n            <jats:p>Estimated effective radiation doses were calculated and compared using Digital Imaging and Communications in Medicine (DICOM) information from all included studies. Patient outcomes between groups were compared with time to fracture union as the primary outcome. Secondary outcome measures included the presence of complication defined as infection, malunion, nonunion, failure of nonoperative treatment, painful implants, and implant failure. Other secondary quality outcomes that were recorded included readmission within 30 days and hospital length of stay. Functional quality measures included joint range of motion. Statistical analyses were conducted to identify significant differences between cohorts (significance designated as <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Patient characteristics between cohorts were not significantly different with respect to age, sex, body mass index, comorbidities, injury mechanism, or injury location. Fractures of the elbow, hip, knee, and foot\/ankle were evaluated. Mean clinical follow-up was 9.5 \u00b1 4.9 months for the REDUCTION cohort and 12.4 \u00b1 5.3 months for the conventional CT cohort. Mean estimated effective dose for all REDUCTION scans was 0.15 milliSieverts (mSv) as compared to 1.50 mSv for the conventional CT cohort (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.037). Preoperative diagnosis was confirmed intraoperatively in 49\/50 cases in the REDUCTION cohort compared with 48\/50 cases in the conventional CT cohort (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.79). Outcomes including time to union, range of motion, complications, readmission, treatment failure, reoperation, and length of stay were not significantly different between groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The REDUCTION protocol represents ultralow-dose CT developed for minimizing radiation exposure to patients presenting with traumatic fractures. This protocol resulted in a 10-fold reduction in radiation exposure. No difference in clinical or hospital quality outcomes was detected between patients who received this protocol as compared to those receiving automated dose CT. The REDUCTION protocol is a safe and effective method of performing CT for extremity fractures with significantly reduced radiation risk.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001137","type":"journal-article","created":{"date-parts":[[2018,2,2]],"date-time":"2018-02-02T16:42:42Z","timestamp":1517589762000},"page":"216-222","source":"Crossref","is-referenced-by-count":28,"title":["Ultralow-Dose CT (REDUCTION Protocol) for Extremity Fracture Evaluation Is as Safe and Effective as Conventional CT: An Evaluation of Quality Outcomes"],"prefix":"10.1097","volume":"32","author":[{"given":"Sanjit R.","family":"Konda","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY; and"},{"name":"Department of Orthopaedic Surgery, Jamaica Hospital Medical Center, New York, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abraham M.","family":"Goch","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jack","family":"Haglin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth A.","family":"Egol","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY; and"},{"name":"Department of Orthopaedic Surgery, Jamaica Hospital Medical Center, New York, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1016\/S0363-5023(97)80071-8","article-title":"Radiographic evaluation of osseous displacement following intra-articular fractures of the distal radius: reliability of plain radiography versus computed tomography","volume":"22","author":"Cole","year":"1997","journal-title":"J Hand Surg Am."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"551","DOI":"10.2106\/00004623-197658040-00021","article-title":"The use of tomography in the assessment of fractures of the tibial plateau","volume":"58","author":"Elstrom","year":"1976","journal-title":"J Bone Joint Surg Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"911","DOI":"10.2214\/ajr.145.5.911","article-title":"Computed tomography of calcaneal fractures: anatomy, pathology, dosimetry, and clinical relevance","volume":"145","author":"Guyer","year":"1985","journal-title":"AJR Am J Roentgenol."},{"key":"R4-20230828","first-page":"163","article-title":"Results of a computed tomography protocol evaluating distal third tibial shaft fractures to assess noncontiguous malleolar fractures","volume":"71","author":"Purnell","year":"2011","journal-title":"J Trauma."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.2106\/00004623-200606000-00020","article-title":"The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures","volume":"88","author":"Harness","year":"2006","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1097\/00003086-199602000-00037","article-title":"Axial computed tomography of pilon fractures","volume":"323","author":"Tornetta","year":"1996","journal-title":"Clin Orthop Relat Res."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1177\/1071100713475355","article-title":"Role of preoperative computed tomography scans in operative planning for malleolar ankle fractures","volume":"34","author":"Black","year":"2013","journal-title":"Foot Ankle Int."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/BOT.0000000000000152","article-title":"The treatment of olecranon fractures with 2.4 mm and 2.7 mm plating techniques","volume":"29","author":"Wellman","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"2071","DOI":"10.1001\/archinternmed.2009.440","article-title":"Projected cancer risks from computed tomographic scans performed in the United States in 2007","volume":"169","author":"Berrington de Gonz\u00e1lez","year":"2009","journal-title":"Arch Intern Med."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1148\/rg.287085042","article-title":"Quality initiatives* radiation risk: what you should know to tell your patient","volume":"28","author":"Verdun","year":"2008","journal-title":"Radiographics."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","author":"McCollough","year":"2009","journal-title":"Radiol Clin North Am."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1097\/PTS.0b013e3182948b1a","article-title":"Trends in computed tomography utilization rates: a longitudinal practice-based study","volume":"10","author":"Hess","year":"2014","journal-title":"J Patient Saf."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1097\/BOT.0b013e31828b7001","article-title":"The role of computed tomography in the assessment of open periarticular fractures associated with deep knee wounds level of evidence: prognostic level IV. See instructions for authors for a complete description of levels of evidence","volume":"27","author":"Konda","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1097\/BOT.0b013e3182821505","article-title":"Computed tomography scan to detect intra-articular air in the knee joint: a cadaver study to define a low radiation dose imaging protocol","volume":"27","author":"Konda","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","first-page":"61","article-title":"Open knee joint injuries: an evidence-based approach to management","volume":"72","author":"Konda","year":"2014","journal-title":"Bull Hosp Jt Dis."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.1302\/0301-620X.98B12.BJJ-2016-0336.R1","article-title":"The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using CT in orthopaedic injury (REDUCTION) protocol effective?","volume":"98-B","author":"Konda","year":"2016","journal-title":"Bone Joint J."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1148\/radiol.2481071451","article-title":"Effective doses in radiology and diagnostic nuclear medicine: a catalog","volume":"248","author":"Mettler","year":"2008","journal-title":"Radiology."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1148\/radiol.14132903","article-title":"Estimates of effective dose for CT scans of the lower extremities","volume":"273","author":"Saltybaeva","year":"2014","journal-title":"Radiology."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.2106\/JBJS.H.01199","article-title":"Radiation exposure from musculoskeletal computerized tomographic scans","volume":"91","author":"Biswas","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N Engl J Med."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1118\/1.3515864","article-title":"Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients","volume":"38","author":"Li","year":"2011","journal-title":"Med Phys."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1148\/rg.292085078","article-title":"Schatzker classification of tibial plateau fractures: use of CT and MR imaging improves assessment","volume":"29","author":"Markhardt","year":"2009","journal-title":"Radiographics."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1080\/02841850410003310","article-title":"Multidetector computed tomography diagnosis of adult elbow fractures","volume":"45","author":"Haapamaki","year":"2004","journal-title":"Acta Radiol."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.2106\/00004623-200608000-00016","article-title":"Two and three-dimensional computed tomography for the classification and management of distal humeral fractures","volume":"88","author":"Doornberg","year":"2006","journal-title":"J Bone Jt Surg."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/00003086-199305000-00012","article-title":"Operative treatment in 120 displaced intraarticular calcaneal fractures","volume":"290","author":"Sanders","year":"1993","journal-title":"Clin Orthop Relat Res."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1016\/j.injury.2015.03.020","article-title":"Ionising radiation exposure in patients with circular frame treatment of distal tibial fractures","volume":"46","author":"Bryant","year":"2015","journal-title":"Injury."},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.2214\/AJR.12.9720","article-title":"CT radiation dose: current controversies and dose reduction strategies","volume":"201","author":"Costello","year":"2013","journal-title":"AJR Am J Roentgenol."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s10140-009-0801-2","article-title":"What ER radiologists need to know about radiation risks","volume":"16","author":"Huda","year":"2009","journal-title":"Emerg Radiol."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"830319","DOI":"10.1155\/2013\/830319","article-title":"Investigation of occult hip Fractures: the use of CT and MRI","volume":"2013","author":"Gill","year":"2013","journal-title":"ScientificWorldJournal."},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"953","DOI":"10.2214\/AJR.14.13317","article-title":"How to appropriately calculate effective dose for CT using either size-specific dose estimates or dose-length product","volume":"204","author":"Brady","year":"2015","journal-title":"AJR Am J Roentgenol."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.4065\/mcp.2010.0260","article-title":"Radiation risk from medical imaging","volume":"85","author":"Lin","year":"2010","journal-title":"Mayo Clin Proc."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201805000-00002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:13:02Z","timestamp":1693203182000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201805000-00002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":32,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001137","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}