{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T14:07:01Z","timestamp":1790950021216,"version":"4.1.0"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To determine the proximity of neurovascular structures to multiplanar distal interlocking screws and proximal interlocking devices for an antegrade inserted humeral nail.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Humeral nails (Depuy Synthes Humeral Nail-EX, Paoli, PA) were inserted into 10 matched cadavers with 3 distal interlocking trajectories: anterior to posterior (A-P), anterolateral to posteromedial, and anteromedial to posterolateral (AM-PL). The distance of the screw path and screw head to the radial, lateral antebrachial cutaneous nerve (LACN), and median nerves and the brachial artery was measured. Proximally, the distance of spiral blades and\/or interlocking screws to the axillary nerve was measured.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The median distance of the screw path\/screw head inserted (A-P) to the LACN was 0 mm\/0 mm in the left arm and 3.5 mm\/1.6 mm in the right arm. The median distance of the screw path\/screw head inserted AM-PL to the median nerve was 7.08 mm\/0 mm in the left arm and 0 mm\/0.12 mm in the right arm. The median distance of the screw path\/screw head inserted AM-PL to the brachial artery was 4.05 mm\/3.83 mm in the left arm and 2.19 mm\/2.84 mm in the right arm. The humeral head was radiographically divided into 3 zones. The average distances of the axillary nerve to interlocking devices placed into zone 2 and zone 3 of the humeral head are 14.65 mm and 1.07 mm, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>When using the DePuy Synthes Humeral Nail-EX, AM-PL screws may risk the median nerve and brachial artery; thus, this trajectory is not recommended. The LACN may be at risk with A-P and to a lesser degree, anterolateral to posteromedial screws. Proximally, interlocking devices in zone 3 of the humeral head may risk the axillary nerve.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001182","type":"journal-article","created":{"date-parts":[[2018,5,9]],"date-time":"2018-05-09T05:42:16Z","timestamp":1525844536000},"page":"e300-e303","source":"Crossref","is-referenced-by-count":2,"title":["The Relationship of Multiplanar Distal and Uniplanar Proximal Interlocking Screws to Neurovascular Structures with the Depuy Synthes Humeral Nail-EX: An Anatomic Study"],"prefix":"10.1097","volume":"32","author":[{"given":"Garrett","family":"Steinmetz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Tobey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Spencer","family":"Skinner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lindsay","family":"Hickerson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1302\/0301-620X.88B11.17634","article-title":"Fractures of the shaft of the humerus. An epidemiologic study of 401 fractures","volume":"88-B","author":"Ekholm","year":"2006","journal-title":"J Bone Joint Surg Br."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.2106\/JBJS.RVW.N.00119","article-title":"Treatment of humeral shaft fractures: a critical analysis review","volume":"3","author":"Attum","year":"2015","journal-title":"JBJS Rev."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.jse.2012.06.007","article-title":"Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis","volume":"22","author":"Ouyang","year":"2013","journal-title":"J Shoulder Elb Surg."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1177\/230949900901700202","article-title":"Locked intramedullary nailing versus dynamic compression plating for humeral shaft fractures","volume":"17","author":"Putti","year":"2009","journal-title":"J Orthop Surg (Hong Kong)."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1080\/17453670610046037","article-title":"Compression plating versus intramedullary nailing of humeral shaft fractures\u2013a meta-analysis","volume":"77","author":"Bhandari","year":"2006","journal-title":"Acta Orthop."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1302\/0301-620X.82B3.0820336","article-title":"Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial","volume":"82","author":"McCormack","year":"2000","journal-title":"J Bone Joint Surg Br."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1007\/s00264-006-0200-1","article-title":"Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study","volume":"31","author":"Changulani","year":"2007","journal-title":"Int Orthop."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1302\/0301-620X.74B4.1624516","article-title":"Locked nailing of humeral shaft fractures. Experience in Edinburgh over a two-year period","volume":"74","author":"Robinson","year":"1992","journal-title":"J Bone Joint Surg Br."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/00005131-200410000-00001","article-title":"The relationship of proximal locking screws to the axillary nerve during antegrade humeral nail insertion of four commercially available implants","volume":"18","author":"Prince","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1016\/j.injury.2007.04.014","article-title":"The risk of injury to neurovascular structures from distal locking screws of the unreamed humeral nail (UHN): a cadaveric study","volume":"38","author":"Noger","year":"2007","journal-title":"Injury"},{"key":"R11-20230828","first-page":"593","article-title":"The risk of neurovascular injury with distal locking screws of humeral intramedullary nails","volume":"19","author":"Rupp","year":"1996","journal-title":"Orthopedics"},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S0020-1383(01)00176-0","article-title":"Iatrogenic nerve injury with Russel-Taylor humeral nail","volume":"34","author":"Blyth","year":"2003","journal-title":"Injury"},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/00005131-200307000-00004","article-title":"Relationship of the axillary nerve to the proximal screws of a flexible humeral nail system: an anatomic study","volume":"17","author":"Albritton","year":"2003","journal-title":"J Orthop Trauma."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"697","DOI":"10.3928\/0147-7447-19920601-05","article-title":"The risk of injury to the axillary nerve, artery, and vein from proximal locking screws of humeral intramedullary nails","volume":"15","author":"Riemer","year":"1992","journal-title":"Orthopedics"},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1016\/j.injury.2014.05.006","article-title":"Risk of injury to the axillary nerve during antegrade proximal humeral blade nail fixation\u2014an anatomical study","volume":"45","author":"Spiegelberg","year":"2014","journal-title":"Injury"},{"key":"R16-20230828","first-page":"215","article-title":"Distal interlocking during intramedullary nailing of the humerus","volume":"317","author":"Moran","year":"1995","journal-title":"Clin Orthop Relat Res."},{"key":"R17-20230828","first-page":"247","article-title":"Anatomic considerations of locked humeral nailing","author":"Lin","year":"1999","journal-title":"Clin Orthop Relat Res."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201808000-00013","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:33:28Z","timestamp":1693204408000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201808000-00013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001182","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,8]]}}}