{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T11:05:26Z","timestamp":1794654326611,"version":"4.9.1"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To compare outcomes and costs between locking and nonlocking (NL) constructs in the treatment of bicondylar tibial plateau (BTP) fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 academic trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients:<\/jats:title>\n            <jats:p>All patients who presented with complete articular, BTP fractures OTA\/AO 41-C and Schatzker VI between 2013 and 2015 were screened (n = 112). Patients treated with a mode of fixation other than plate-and-screw were excluded. Fifty-six patients with a minimum follow-up of 12 months were included in the analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Operative fixation of BTP fractures with locking (n = 29) or NL (n = 27) implants.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main outcome measurements:<\/jats:title>\n            <jats:p>Implant cost, patient-reported outcomes (PROMIS physical function and pain interference), clinical, and radiographic outcomes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There were no differences between the 2 groups with respect to demographics, injury characteristics, radiographic outcomes (change in alignment), or clinical outcomes (PROMIS, reoperation, nonunion, and infection). Implant costs were significantly greater in the locking group compared with the NL group (mean L, $4453; mean NL, $2569; <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.01).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>This study demonstrated improved value of treatment (less cost with no difference in clinical outcome) with NL implants for BTP fractures when dual-plate fixation strategies are performed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001188","type":"journal-article","created":{"date-parts":[[2018,5,9]],"date-time":"2018-05-09T05:42:16Z","timestamp":1525844536000},"page":"333-337","source":"Crossref","is-referenced-by-count":18,"title":["Locking Plate Fixation in a Series of Bicondylar Tibial Plateau Fractures Raises Treatment Costs Without Clinical Benefit"],"prefix":"10.1097","volume":"32","author":[{"given":"Matthew","family":"Cavallero","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Rosales","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jesse","family":"Caballero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter W.","family":"Virkus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurence B.","family":"Kempton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greg E.","family":"Gaski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","first-page":"149","article-title":"Complications of internal fixation of tibial plateau fractures","volume":"23","author":"Young","year":"1994","journal-title":"Orthop Rev."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/00003086-198401000-00025","article-title":"Tibial plateau fractures: an analysis of the results of treatment in 60 patients","volume":"182","author":"Blokker","year":"1984","journal-title":"Clin Orthop Rel Res."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/00005131-198702010-00001","article-title":"Tibial plateau fractures: definition, demographics, treatment rationale, and long-term results of closed traction management or operative reduction","volume":"1","author":"Moore","year":"1987","journal-title":"J Orthop Trauma."},{"key":"R4-20230828","first-page":"1433","article-title":"Internal versus external fixation of bicondylar tibial plateau fractures","volume":"21","author":"Mallik","year":"1992","journal-title":"Orthop Rev."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1097\/00005131-200411000-00001","article-title":"Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique","volume":"18","author":"Barei","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1016\/j.injury.2011.10.035","article-title":"Fracture pattern and fixation type related to loss of reduction in bicondylar tibial plateau fractures","volume":"43","author":"Weaver","year":"2012","journal-title":"Injury."},{"key":"R7-20230828","first-page":"148","article-title":"Stabilization of the posteromedial fragment in bicondylar tibial plateau fractures: a mechanical comparison of locking and nonlocking single and dual plating methods","volume":"69","author":"Yoo","year":"2010","journal-title":"J Trauma."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1097\/BOT.0b013e3180500359","article-title":"Biomechanical analysis of bicondylar tibial plateau fixation: how does lateral locking plate fixation compare to dual plate fixation?","volume":"21","author":"Higgins","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1097\/01.TA.0000112326.09272.13","article-title":"Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating","volume":"57","author":"Egol","year":"2004","journal-title":"J Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/01.blo.0000071754.41516.e9","article-title":"Bicondylar tibial plateau fractures: a biomechanical study","volume":"412","author":"Mueller","year":"2003","journal-title":"Clin Orthop."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1097\/00005131-200409000-00011","article-title":"Less invasive stabilization of complex tibial plateau fractures: a biomechanical evaluation of a unilateral locked screw plate and double plating","volume":"18","author":"Gosling","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.knee.2015.02.002","article-title":"A comparison of lateral fixation versus dual plating for simple bicondylar fractures","volume":"22","author":"Yao","year":"2015","journal-title":"Knee."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.knee.2007.12.001","article-title":"A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures","volume":"15","author":"Jiang","year":"2008","journal-title":"Knee."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"324573","DOI":"10.1155\/2014\/324573","article-title":"Comparison of functional outcomes of tibial plateau fractures treated with nonlocking and locking plate fixations: a nonrandomized clinical trial","volume":"2014","author":"Tahririan","year":"2014","journal-title":"ISRN Orthop."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/s13018-014-0062-y","article-title":"Comparison of outcome of unilateral locking plate and dual plating in the treatment of bicondylar tibial plateau fractures","volume":"9","author":"Lee","year":"2014","journal-title":"J Orthop Surg Res."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"193","DOI":"10.4103\/0019-5413.152478","article-title":"Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures","volume":"49","author":"Neogi","year":"2015","journal-title":"Indian J Orthop."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00003086-200510000-00036","article-title":"Single lateral locked screw plating of bicondylar tibial plateau fractures","volume":"439","author":"Gosling","year":"2005","journal-title":"Clin Orthop Rel Res."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u20142007: Orthopaedic Trauma Association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R19-20230828","first-page":"94","article-title":"The tibial plateau fracture: the Toronto experience 1968\u20131975","volume":"138","author":"Schatzker","year":"1979","journal-title":"Clin Orthop Rel Res."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"e219","DOI":"10.1097\/BOT.0000000000000263","article-title":"Does fracture care make money for the hospital? An analysis of hospital revenues and costs for treatment of common fractures","volume":"29","author":"Kleweno","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1097\/BOT.0000000000000721","article-title":"The clinical and economic impact of generic locking plate utilization at a level II trauma center","volume":"30","author":"Mcphillamy","year":"2016","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201807000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:42:12Z","timestamp":1693204932000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201807000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":21,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001188","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7]]}}}