{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T05:41:53Z","timestamp":1788414113366,"version":"build-2803163510"},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To evaluate the early clinical results of distal femur fractures treated with carbon fiber\u2013reinforced polyetheretherketone (CFR-PEEK) plates compared with stainless steel (SS) lateral locking plates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Retrospective comparative cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>ACS Level I trauma center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients\/Participants:<\/jats:title>\n                    <jats:p>Twenty-two patients (11 SS, 11 CFR-PEEK) with closed distal femur fractures treated by a single surgeon over a 6-year period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcome Measurements:<\/jats:title>\n                    <jats:p>Nonunion, hardware failure, reoperation, time to full weight-bearing, and time union were assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The CFR-PEEK cohort was on average older (71 vs. 57 years,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.03) and more likely to have diabetes (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.02). Nonunion was diagnosed in 4\/11 (36%) patients in the SS group and 1\/11 (9%) patients in the CFR-PEEK group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.12). Hardware failure occurred in 2 SS patients (18%) compared with none in the CFR-PEEK group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.14). Time to full weight\u2013bearing was similar between groups, occurring at 9.9 and 12.4 weeks in the CFR-PEEK and SS groups, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.23). Time to radiographic union averaged 12.4 weeks in the SS group and 18.7 weeks in the CFR-PEEK group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.26). There were 4 reoperations in the SS group and 1 in the CFR-PEEK group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.12).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>CFR-PEEK plates show encouraging short-term results in the treatment of distal femur fractures with a comparable nonunion, reoperation, and hardware failure rates to those treated with SS plates. This data suggest that CFR-PEEK plates may be a viable alternative to SS plates in fixation of these fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000001223","type":"journal-article","created":{"date-parts":[[2018,5,18]],"date-time":"2018-05-18T11:30:25Z","timestamp":1526643025000},"page":"386-390","source":"Crossref","is-referenced-by-count":31,"title":["Early Comparative Outcomes of Carbon Fiber\u2013Reinforced Polymer Plate in the Fixation of Distal Femur Fractures"],"prefix":"10.1097","volume":"32","author":[{"given":"Phillip M.","family":"Mitchell","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam K.","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Southern California Keck School of Medicine, Los Angeles, CA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cory A.","family":"Collinge","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce H.","family":"Ziran","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Trauma, The Hughston Clinic at Gwinnett Medical Center, Atlanta, GA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kate G.","family":"Hartley","sequence":"additional","affiliation":[{"name":"Departments of Radiology, Orthopaedic Surgery, and Emergency Medicine, Vanderbilt University Medical Center, Nashville, TN."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. Alex","family":"Jahangir","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/BOT.0000000000000302","article-title":"Management of distal femur fractures with modern plates and nails: state of the art","volume":"29","author":"Beltran","year":"2015","journal-title":"J Orthop Trauma."},{"issue":"suppl 2","key":"R2-20230828","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.1097\/BOT.0000000000000621","article-title":"Treatment options for distal femur fractures","volume":"30","author":"von Keudell","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"276","DOI":"10.2106\/JBJS.O.00684","article-title":"Motion predicts clinical callus formation: construct-specific finite element analysis of supracondylar femoral fractures","volume":"98","author":"Elkins","year":"2016","journal-title":"J bone Joint Surg Am volume."},{"issue":"suppl 1","key":"R4-20230828","doi-asserted-by":"crossref","first-page":"S4","DOI":"10.1097\/BOT.0b013e318207093e","article-title":"Biomechanical principles and mechanobiologic aspects of flexible and locked plating","volume":"25","author":"Claes","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J bone Joint Surg Br volume."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"e241","DOI":"10.1097\/BOT.0000000000000860","article-title":"Implant material, type of fixation at the shaft, and position of plate modify biomechanics of distal femur plate osteosynthesis","volume":"31","author":"Kandemir","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"466","DOI":"10.2106\/JBJS.O.00705","article-title":"Dynamic stabilization with active locking plates delivers faster, stronger, and more symmetric fracture-healing","volume":"98","author":"Bottlang","year":"2016","journal-title":"J bone Joint Surg Am volume."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.clinbiomech.2015.02.006","article-title":"Working length of locking plates determines interfragmentary movement in distal femur fractures under physiological loading","volume":"30","author":"Mardian","year":"2015","journal-title":"Clin Biomech (Bristol, Avon)."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/BOT.0000000000000315","article-title":"Dynamic locked plating of distal femur fractures","volume":"29","author":"Linn","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1097\/01.bot.0000438368.44077.04","article-title":"Dynamic fixation of distal femur fractures using far cortical locking screws: a prospective observational study","volume":"28","author":"Bottlang","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"1985","DOI":"10.2106\/JBJS.H.01038","article-title":"Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength","volume":"91","author":"Bottlang","year":"2009","journal-title":"J bone Joint Surg Am volume."},{"key":"R12-20230828","first-page":"250","article-title":"Less invasive stabilization system for treatment of distal femur fractures","volume":"33","author":"Ricci","year":"2004","journal-title":"Am J Orthop (Belle Mead, NJ)."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","article-title":"Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases","volume":"28","author":"Ricci","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1097\/00005131-200409000-00005","article-title":"Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO\/OTA types A2, A3, C2, and C3)","volume":"18","author":"Weight","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1302\/0301-620X.99B7.BJJ-2016-0585.R1","article-title":"\u201cModern\u201d distal femoral locking plates allow safe, early weight-bearing with a high rate of union and low rate of failure: five-year experience from a United Kingdom major trauma centre","volume":"99-b","author":"Poole","year":"2017","journal-title":"Bone Joint J."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.arth.2016.06.006","article-title":"Open reduction vs distal femoral replacement arthroplasty for comminuted distal femur fractures in the patients 70 years and older","volume":"32","author":"Hart","year":"2017","journal-title":"J arthroplasty."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1097\/BOT.0000000000000391","article-title":"Early mechanical failures of the synthes variable angle locking distal femur plate","volume":"30","author":"Tank","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/BOT.0000000000000593","article-title":"Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures","volume":"30","author":"Rodriguez","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R19-20230828","first-page":"e212","article-title":"LCP versus liss in the treatment of open and closed distal femur fractures: does it make a difference?","volume":"30","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/BOT.0000000000000450","article-title":"Are locking constructs in distal femoral fractures always best? A prospective multicenter randomized controlled trial comparing the less invasive stabilization system with the minimally invasive dynamic condylar screw system","volume":"30","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1007\/s11999-011-1870-6","article-title":"2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures","volume":"469","author":"Henderson","year":"2011","journal-title":"Clin Orthop Relat Res."},{"issue":"suppl 1","key":"R22-20230828","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1097\/BOT.0b013e3182070127","article-title":"Locking plates for distal femur fractures: is there a problem with fracture healing?","volume":"25","author":"Henderson","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1097\/00005131-200605000-00013","article-title":"Operative treatment of acute distal femur fractures: systematic review of 2 comparative studies and 45 case series (1989 to 2005)","volume":"20","author":"Zlowodzki","year":"2006","journal-title":"J Orthop Trauma."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1177\/1938640017718343","article-title":"A retrospective case series of carbon fiber plate fixation of ankle fractures","volume":"11","author":"Pinter","year":"2018","journal-title":"Foot Ankle Spec."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","article-title":"Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate","volume":"24","author":"Schliemann","year":"2015","journal-title":"J shoulder Elb Surg."},{"issue":"suppl 1","key":"R26-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1007\/s12306-015-0371-2","article-title":"Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate","volume":"99","author":"Rotini","year":"2015","journal-title":"Musculoskelet Surg."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","article-title":"A new volar plate made of carbon-fiber-reinforced polyetheretherketone for distal radius fracture: analysis of 40 cases","volume":"15","author":"Tarallo","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1016\/j.injury.2003.10.014","article-title":"Carbon fibre plates in the treatment of femoral periprosthetic fractures","volume":"35","author":"Baker","year":"2004","journal-title":"Injury"},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1054\/arth.2002.30291","article-title":"The use of a carbon fiber plate for periprosthetic supracondylar femoral fractures","volume":"17","author":"Al-Shawi","year":"2002","journal-title":"J arthroplasty."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1302\/0301-620X.74B1.1732273","article-title":"Carbon-fibre reinforced plates for problem fractures","volume":"74","author":"Pemberton","year":"1992","journal-title":"J Bone Joint Surg Br volume."},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/j.1097-4636.1987.tb00029.x","article-title":"The design and analysis of a laminated partially degradable composite bone plate for fracture fixation","volume":"21","author":"Zimmerman","year":"1987","journal-title":"J Biomed Mater Res."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"825","DOI":"10.3928\/01477447-20141124-05","article-title":"Use of carbon-fiber-reinforced composite implants in orthopedic surgery","volume":"37","author":"Hak","year":"2014","journal-title":"Orthopedics"},{"key":"R33-20230828","first-page":"117","article-title":"Carbon fiber reinforced plastic (CFRP) plates versus stainless steel dynamic compression plates in the treatment of fractures of the tibiae in dogs","author":"Skirving","year":"1987","journal-title":"Clin Orthop Relat Res."},{"key":"R34-20230828","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/0142-9612(85)90074-2","article-title":"The use of short carbon fibre reinforced thermoplastic plates for fracture fixation","volume":"6","author":"Gillett","year":"1985","journal-title":"Biomaterials"},{"key":"R35-20230828","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1302\/0301-620X.64B1.7040407","article-title":"The use of semi-rigid carbon-fibre-reinforced plastic plates for fixation of human fractures. Results of preliminary trials","volume":"64","author":"Tayton","year":"1982","journal-title":"J Bone Joint Surg Br volume."},{"key":"R36-20230828","doi-asserted-by":"crossref","first-page":"091002","DOI":"10.1115\/1.4027669","article-title":"Biomechanical analysis of a new carbon fiber\/flax\/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate","volume":"136","author":"Bagheri","year":"2014","journal-title":"J Biomechanical Eng."},{"key":"R37-20230828","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jmbbm.2014.03.008","article-title":"Biomechanical fatigue analysis of an advanced new carbon fiber\/flax\/epoxy plate for bone fracture repair using conventional fatigue tests and thermography","volume":"35","author":"Bagheri","year":"2014","journal-title":"J Mech Behav Biomed Mater."},{"key":"R38-20230828","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.jmbbm.2012.09.013","article-title":"Carbon fiber reinforced PEEK Optima\u2013a composite material biomechanical properties and wear\/debris characteristics of CF-PEEK composites for orthopedic trauma implants","volume":"17","author":"Steinberg","year":"2013","journal-title":"J Mech Behav Biomed Mater."},{"key":"R39-20230828","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1007\/s10439-006-9102-z","article-title":"Assessment of carbon fibre composite fracture fixation plate using finite element analysis","volume":"34","author":"Saidpour","year":"2006","journal-title":"Ann Biomed Eng."},{"key":"R40-20230828","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":"Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation","volume":"24","author":"Lujan","year":"2010","journal-title":"J Orthop Trauma."},{"key":"R41-20230828","doi-asserted-by":"crossref","first-page":"207","DOI":"10.2106\/00004623-201101190-00013","article-title":"Principles of biomechanics and biomaterials in orthopaedic surgery","volume":"93","author":"Golish","year":"2011","journal-title":"J bone Joint Surg Am volume."},{"key":"R42-20230828","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1302\/0301-620X.67B4.4030870","article-title":"The response of human tissues to carbon reinforced epoxy resin","volume":"67","author":"Howard","year":"1985","journal-title":"J bone Joint Surg Br volume."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00005131-201808000-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:12:52Z","timestamp":1786036372000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00005131-201808000-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8]]},"references-count":42,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001223","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,8]]}}}