{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:56:45Z","timestamp":1792429005549,"version":"4.5.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,11]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To examine the stability of plate (locking and non\u2013) versus screw constructs in the fixation of these fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>An anteromedial coronoid facet fracture (OTA\/AO type 21\u2013B1, O'Driscoll type 2, subtype 3) was simulated in 24 synthetic ulna bones that were then assigned to 3 fracture fixation groups: non\u2013locking plate, locking plate (LP), or screw fixation. Each construct was first cycled in tension (through a simulated medial collateral ligament) and then in compression. They were then loaded to failure (displacement &gt;2 mm). Fracture fragment displacement was recorded with an optical tracking system.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>During tension testing, a mean maximum fragment displacement of 12 \u00b1 13 and 14 \u00b1 9 \u03bcm was seen in the locking and non\u2013locking constructs, respectively. There was no difference in fragment motion between the plated constructs. All screw-only fixed constructs failed during the tension protocol. During compression testing, the mean maximum fragment displacement for the screw-only construct (64 \u00b1 79 \u03bcm) was significantly greater than locking (9 \u00b1 5 \u03bcm) and non\u2013locking constructs (10 \u00b1 9 \u03bcm). During load to failure testing, the maximum load to failure in the screw-only group (316 \u00b1 83 N) was significantly lower than locking (650.4 \u00b1 107 N) and non\u2013locking constructs (550 \u00b1 76 N). There was no difference in load to failure between the plated groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Fixation of anteromedial coronoid fractures (type 2, subtype 3) is best achieved with a plating technique. Although LPs had greater stiffness, they did not offer any advantage over conventional non-LPs with respect to fracture fragment displacement in this study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Clinical Relevance:<\/jats:title>\n            <jats:p>Isolated screw fixation showed inferior stability when compared with plate constructs for these fractures. This could result in loss of fracture reduction leading to instability and posttraumatic arthrosis.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001266","type":"journal-article","created":{"date-parts":[[2018,10,22]],"date-time":"2018-10-22T23:01:23Z","timestamp":1540249283000},"page":"e451-e456","source":"Crossref","is-referenced-by-count":23,"title":["Fixation of Anteromedial Coronoid Facet Fractures: A Biomechanical Evaluation of Plated Versus Screw Constructs"],"prefix":"10.1097","volume":"32","author":[{"given":"John","family":"Morellato","sequence":"first","affiliation":[{"name":"Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hakim","family":"Louati","sequence":"additional","affiliation":[{"name":"Orthopaedics Biomechanics Laboratory, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Desloges","sequence":"additional","affiliation":[{"name":"Hull Hospital, Gatineau, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven","family":"Papp","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Whitcomb","family":"Pollock","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"1 suppl S","key":"R1-20230828","doi-asserted-by":"crossref","first-page":"174S","DOI":"10.1016\/j.jse.2004.09.031","article-title":"Stability of the elbow: osseous constraints","volume":"14","author":"Morrey","year":"2005","journal-title":"J Shoulder Elb Surg"},{"key":"R2-20230828","first-page":"113","article-title":"Difficult elbow fractures: pearls and pitfalls","volume":"52","author":"O'Driscoll","year":"2003","journal-title":"Instr Course Lect"},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.jse.2007.03.013","article-title":"The anteromedial facet of the coronoid process of the ulna","volume":"16","author":"Doornberg","year":"2007","journal-title":"J Shoulder Elb Surg"},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/00003086-199104000-00021","article-title":"Valgus stability of the elbow. A definition of primary and secondary constraints","volume":"265","author":"Morrey","year":"1991","journal-title":"Clin Orthop Relat Res."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1448","DOI":"10.2106\/JBJS.H.00222","article-title":"The effect of anteromedial facet fractures of the coronoid and lateral collateral ligament injury on elbow stability and kinematics","volume":"91","author":"Pollock","year":"2009","journal-title":"J Bone Jt Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.jhsa.2005.08.014","article-title":"Coronoid fracture patterns","volume":"31","author":"Doornberg","year":"2006","journal-title":"J Hand Surg Am."},{"key":"R7-20230828","first-page":"2216","article-title":"Fracture of the anteromedial facet of the coronoid process","volume":"88","author":"Doornberg","year":"2006","journal-title":"J Bone Jt Surg Am."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.1016\/j.jhsa.2006.08.020","article-title":"Fractures of the coronoid process of the ulna","volume":"31","author":"Ring","year":"2006","journal-title":"J Hand Surg Am."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","article-title":"Biomechanics of locked plates and screws","volume":"18","author":"Egol","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.joca.2003.08.005","article-title":"Mechanical response of bovine articular cartilage under dynamic unconfined compression loading at physiological stress levels","volume":"12","author":"Park","year":"2004","journal-title":"Osteoarthr Cartil."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/S0021-9290(96)00166-2","article-title":"Articular cartilage deformation under physiological cyclic loading: apparatus and measurement technique","volume":"30","author":"Barker","year":"1997","journal-title":"J Biomech."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/00003086-199110000-00023","article-title":"Biomechanical study of ligaments around the elbow joint","volume":"271","author":"Regan","year":"1991","journal-title":"Clin Orthop Relat Res."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.jse.2004.09.012","article-title":"An in vitro biomechanical study of a hinged external fixator applied to an unstable elbow","volume":"14","author":"Sekiya","year":"2005","journal-title":"J Shoulder Elb Surg."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/0021-9290(81)90048-8","article-title":"Muscles across the elbow joint: a biomechanical analysis","volume":"14","author":"An","year":"1981","journal-title":"J Biomech"},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1186\/1475-925X-13-134","article-title":"Biomechanics principle of elbow joint for transhumeral prostheses: comparison of normal hand, body-powered, myoelectric & air splint prostheses","volume":"13","author":"Abd Razak","year":"2014","journal-title":"Biomed Eng Online"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201811000-00014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T10:26:49Z","timestamp":1693218409000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201811000-00014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11]]},"references-count":15,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001266","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,11]]}}}