{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T15:41:02Z","timestamp":1783957262024,"version":"3.55.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,11]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To determine the change in stiffness and horizontal translations of a geriatric supracondylar femur fracture model with the addition of distal segment blocking screws versus proximal (long) segment blocking screws to the standard retrograde intramedullary nail construct.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Unstable supracondylar femur fractures (OTA\/AO 33-A3) were created; all specimens were instrumented with a retrograde intramedullary nail. Specimens were divided into 2 groups (6 matched pairs per group). Group 1 compared the standard construct (1 proximal screw and 3 distal screws) to a distally augmented construct, with blocking screws placed in the distal metaphyseal segment. Group 2 compared the distally augmented construct to one in which blocking screws were placed just proximal to the fracture (long segment blocking screws). Specimens were then axially loaded and cycled to failure or run-out.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There was no significant difference in baseline stiffness, survival through cyclic loading, stiffness after cyclic loading, or cycles to failure between femurs treated with distal blocking screws and femurs treated without blocking screws (group 1). Femurs with blocking screws in the long proximal segment had significantly greater baseline stiffness, stiffness after cyclic loading, and less horizontal translation at the fracture site (group 2). There was no difference in survival through cyclic loading or cycles to failure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Long segment blocking screws are biomechanically superior to blocking screws in the distal segment or no blocking screws initially and after cyclic loading in an unstable geriatric supracondylar femur fracture model treated with intramedullary nail.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Clinical Relevance:<\/jats:title>\n            <jats:p>Surgeons may use blocking screws to aid in fracture alignment during retrograde nail fixation. In addition, the placement of long segment blocking screws can help resist failure of fixation in geriatric patients by eliminating the \u201cBell-clapper effect.\u201d<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001284","type":"journal-article","created":{"date-parts":[[2018,8,7]],"date-time":"2018-08-07T20:50:35Z","timestamp":1533675035000},"page":"559-564","source":"Crossref","is-referenced-by-count":21,"title":["Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the \u201cBell-Clapper Effect\u201d"],"prefix":"10.1097","volume":"32","author":[{"given":"Darryl","family":"Auston","sequence":"first","affiliation":[{"name":"Hughston Orthopaedic Trauma, Orange Park Medical Center, Orange Park, FL;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Donohue","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of South Florida, Tampa, FL;"},{"name":"Orthopaedic Trauma Service, Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyle","family":"Stoops","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education, Tampa, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Cox","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of South Florida, Tampa, FL;"},{"name":"Orthopaedic Trauma Service, Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel","family":"Diaz","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education, Tampa, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon","family":"Santoni","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education, Tampa, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Mir","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of South Florida, Tampa, FL;"},{"name":"Orthopaedic Trauma Service, Florida Orthopaedic Institute, Tampa, FL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1007\/s11999-010-1530-2","article-title":"Mortality after distal femur fractures in elderly patients","volume":"469","author":"Streubel","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.injury.2015.02.016","article-title":"Distal femoral fractures: the need to review the standard of care","volume":"46","author":"Smith","year":"2015","journal-title":"Injury"},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/BOT.0b013e3181ad61f2","article-title":"Distal third femur fractures treated with retrograde femoral nailing and blocking screws","volume":"23","author":"Ostrum","year":"2009","journal-title":"J Orthop trauma"},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/j.injury.2004.11.029","article-title":"The role and efficacy of retrograding nailing for the treatment of diaphyseal and distal femoral fractures: a systematic review of the literature","volume":"36","author":"Papadokostakis","year":"2005","journal-title":"Injury"},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00005131-200103000-00003","article-title":"Retrograde versus antegrade nailing of femoral shaft fractures","volume":"15","author":"Ricci","year":"2001","journal-title":"J Orthop trauma"},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/00005131-199308000-00001","article-title":"Retrograde reamed femoral nailing","volume":"7","author":"Sanders","year":"1993","journal-title":"J Orthop trauma"},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1097\/00005131-200102000-00003","article-title":"Angular malalignment after intramedullary nailing of femoral shaft fractures","volume":"15","author":"Ricci","year":"2001","journal-title":"J Orthop trauma"},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1302\/0301-620X.96B1.31135","article-title":"Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures: a cadaver-based laboratory investigation","volume":"96-B","author":"Pekmezci","year":"2014","journal-title":"Bone Joint J"},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00005131-200409000-00004","article-title":"Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures","volume":"18","author":"Zlowodzki","year":"2004","journal-title":"J Orthop trauma"},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"e936","DOI":"10.3928\/01477447-20130624-26","article-title":"Blocking screws for the treatment of distal femur fractures","volume":"36","author":"Seyhan","year":"2013","journal-title":"Orthopedics"},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/BOT.0000000000000195","article-title":"Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing","volume":"29","author":"Chan","year":"2015","journal-title":"J Orthop trauma"},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1302\/0301-620X.81B6.0810963","article-title":"The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails","volume":"81","author":"Krettek","year":"1999","journal-title":"J Bone Joint Surg Br"},{"issue":"suppl 2","key":"R13-20230828","doi-asserted-by":"crossref","first-page":"17","DOI":"10.2106\/00004623-200412002-00004","article-title":"The logic and clinical applications of blocking screws","volume":"86-A","author":"Stedtfeld","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","article-title":"Hip contact forces and gait patterns from routine activities","volume":"34","author":"Bergmann","year":"2001","journal-title":"J Biomech"},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/BOT.0b013e3182a1f54b","article-title":"Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures","volume":"27","author":"Hoffmann","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BOT.0000000000000008","article-title":"Malpositioning of the lag screws by 1- or 2-screw nailing systems for pertrochanteric femoral fractures: a biomechanical comparison of gamma 3 and intertan","volume":"28","author":"Nuchtern","year":"2014","journal-title":"J Orthop Trauma"},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1097\/00005131-200011000-00010","article-title":"Biomechanical evaluation of dual-energy x-ray absorptiometry for predicting fracture loads of the infant femur for injury investigation: an in vitro porcine model","volume":"14","author":"Pierce","year":"2000","journal-title":"J Orthop Trauma"},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.2106\/JBJS.H.01722","article-title":"Internal fixation of type-C distal femoral fractures in osteoporotic bone","volume":"92","author":"W\u00e4hnert","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/0020-1383(96)00008-3","article-title":"Unreamed intramedullary nailing of femoral shaft fractures: operative technique and early clinical experience with the standard locking option","volume":"27","author":"Krettek","year":"1996","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201811000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T10:26:35Z","timestamp":1693218395000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201811000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11]]},"references-count":19,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001284","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,11]]}}}