{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T23:22:47Z","timestamp":1788823367420,"version":"build-2803163510"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To evaluate the accuracy of reduction of the acetabular articular surface using an intraoperative computed tomography scanner (O-Arm) and screw navigation compared with a classical open technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Prospective matched cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Tertiary referral center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients\/Participants:<\/jats:title>\n                    <jats:p>Adult patients with acute acetabular fractures were included in the study. All patients were treated by 2 senior surgeons using intraoperative imaging and screw navigation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcome Measurements:<\/jats:title>\n                    <jats:p>\n                      The primary outcome measure was articular reduction. Secondary outcomes were radiation dosage, operative variables [operative time, time for image acquisition, intraoperative bleeding (cell saver), number of surgical plates, and number of screws], and postoperative variables (first postoperative day pain on the visual analog scale, postoperative transfusion, and hemoglobin change).\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05 was considered statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Thirty-five patients were treated in the inclusion period (2016\u20132017) and were matched to 35 cases in our database (2013\u20132016). Mean age was 43 years, and the most common fracture type was a both-column fracture (OTA\/AO type C). Postoperative image analysis showed that reduction was achieved in 87.1% of the cases in the O-Arm group versus 64.7% in the control group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). Mean gap of the articular fragments was 3.6 mm in the O-Arm group compared with 5.6 mm (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.01) in the control group. There was no significant difference between the 2 groups in regards to all other studied variables except a decrease in intraoperative blood loss and transfusions and an increase in surgical time with the O-Arm group. Finally, the total radiation dose was decreased using the intraoperative O-Arm compared with a routine postoperative computed tomography scan (dose length product in O-Arm: 498 mGy.cm; dose length product in historical group: 715 mGy.cm).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Using intraoperative imaging and screw navigation for displaced acetabular fractures allow screw navigation with increasing articular surface reduction accuracy. Operative and anesthesia times were not increased, whereas radiation exposure to the patient was significantly decreased. We recommend the use of intraoperative imaging for the treatment of displaced acetabular fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000001324","type":"journal-article","created":{"date-parts":[[2018,10,7]],"date-time":"2018-10-07T21:28:58Z","timestamp":1538947738000},"page":"612-616","source":"Crossref","is-referenced-by-count":31,"title":["Intraoperative Cone Beam Tomography and Navigation for Displaced Acetabular Fractures: A Comparative Study"],"prefix":"10.1097","volume":"32","author":[{"given":"Amer","family":"Sebaaly","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Centre Hospitalier Paris Saint Joseph, Paris, France; and"},{"name":"Saint Joseph University, Faculty of Medicine, Beirut, Lebanon."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pomme","family":"Jouffroy","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Centre Hospitalier Paris Saint Joseph, Paris, France; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Emmanuel Moreau","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Centre Hospitalier Paris Saint Joseph, Paris, France; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Camille","family":"Rodaix","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Centre Hospitalier Paris Saint Joseph, Paris, France; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guillaume","family":"Riouallon","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Centre Hospitalier Paris Saint Joseph, Paris, France; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230928","doi-asserted-by":"crossref","first-page":"S273","DOI":"10.1016\/j.otsr.2013.03.002","article-title":"Percutaneous iliosacral screw fixation in unstable pelvic ring lesions: the interest of O-ARM CT-guided navigation","volume":"99","author":"Coste","year":"2013","journal-title":"Orthop Traumatol Surg Res."},{"key":"R2-20230928","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.injury.2015.01.038","article-title":"Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation","volume":"46","author":"Wong","year":"2015","journal-title":"Injury."},{"key":"R3-20230928","first-page":"481","article-title":"The surgical treatment of acetabular fractures","volume":"59","author":"Moed","year":"2010","journal-title":"Instr Course Lect."},{"key":"R4-20230928","first-page":"423","article-title":"The study of plate-screw fixation in the posterior wall of acetabulum using computed tomography images","volume":"69","author":"Wu","year":"2010","journal-title":"J Trauma."},{"key":"R5-20230928","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1097\/00003086-198704000-00019","article-title":"Extrinsic femoral artery occlusion following internal fixation of an acetabular fracture: a case report","author":"Johnson","year":"1987","journal-title":"Clin Orthop Relat Res."},{"key":"R6-20230928","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1177\/230949900601400204","article-title":"The usefulness of computed tomography following open reduction and internal fixation of acetabular fractures","volume":"14","author":"O'Shea","year":"2006","journal-title":"J Orthop Surg (Hong Kong)."},{"key":"R7-20230928","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1097\/01.bco.0000192521.48411.b3","article-title":"Assessment of clinical outcome after acetabular fracture","volume":"17","author":"Borrelli","year":"2006","journal-title":"Curr Opin Orthop."},{"key":"R8-20230928","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.2106\/JBJS.16.01446","article-title":"Postoperative CT is superior for acetabular fracture reduction assessment and reliably predicts hip survivorship","volume":"99","author":"Verbeek","year":"2017","journal-title":"J Bone Joint Surg Am."},{"key":"R9-20230928","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1097\/01.brs.0000194788.45002.1b","article-title":"An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws","volume":"31","author":"Smith","year":"2006","journal-title":"Spine (Phila Pa 1976)."},{"key":"R10-20230928","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1186\/1471-2474-11-153","article-title":"2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries\u2013a case series","volume":"11","author":"Gras","year":"2010","journal-title":"BMC Musculoskelet Disord."},{"key":"R11-20230928","first-page":"1501","article-title":"Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional)","volume":"69","author":"Zwingmann","year":"2010","journal-title":"J Trauma."},{"key":"R12-20230928","doi-asserted-by":"crossref","first-page":"e2470","DOI":"10.1097\/MD.0000000000002470","article-title":"Comparison of isocentric C-Arm 3-dimensional navigation and conventional fluoroscopy for percutaneous retrograde screwing for anterior column fracture of acetabulum","volume":"95","author":"He","year":"2016","journal-title":"Med Baltim."},{"key":"R13-20230928","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1097\/TA.0b013e318254308f","article-title":"Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures","volume":"73","author":"Oberst","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"R14-20230928","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.otsr.2016.07.005","article-title":"The added value of intraoperative CT scanner and screw navigation in displaced posterior wall acetabular fracture with articular impaction","volume":"102","author":"Sebaaly","year":"2016","journal-title":"Orthop Traumatol Surg Res."},{"issue":"10 suppl","key":"R15-20230928","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u2014Orthopaedic Trauma Association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R16-20230928","doi-asserted-by":"crossref","first-page":"2523","DOI":"10.2106\/JBJS.I.01617","article-title":"Comparative evaluation of postreduction intra-articular distal radial fractures by radiographs and multidetector computed tomography","volume":"92","author":"Arora","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"R17-20230928","doi-asserted-by":"crossref","first-page":"512","DOI":"10.2106\/00004623-200303000-00018","article-title":"Computed tomographic assessment of fractures of the posterior wall of the acetabulum after operative treatment","volume":"85","author":"Moed","year":"2003","journal-title":"J. Bone Joint Surg Am."},{"key":"R18-20230928","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.otsr.2016.10.020","article-title":"Improved acetabular fracture diagnosis after training in a CT-based method","volume":"103","author":"Jouffroy","year":"2017","journal-title":"Orthop Traumatol Surg Res."},{"key":"R19-20230928","doi-asserted-by":"crossref","first-page":"559","DOI":"10.2106\/JBJS.K.00444","article-title":"Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures","volume":"94","author":"Tannast","year":"2012","journal-title":"J Bone Joint Surg."},{"key":"R20-20230928","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.spinee.2015.11.020","article-title":"Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation","volume":"16","author":"Mendelsohn","year":"2016","journal-title":"Spine J."},{"key":"R21-20230928","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/BPO.0000000000000504","article-title":"Switching to a pediatric dose O-Arm protocol in spine surgery significantly reduced patient radiation exposure","volume":"36","author":"Su","year":"2016","journal-title":"J Pediatr Orthop."},{"key":"R22-20230928","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/BRS.0000000000001778","article-title":"Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial","volume":"42","author":"Hyun","year":"2017","journal-title":"Spine (Phila. Pa. 1976)."},{"key":"R23-20230928","first-page":"157","article-title":"Surgical treatment of acetabular fractures","author":"Letournel","year":"1987","journal-title":"Hip."},{"key":"R24-20230928","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1177\/230949901502300110","article-title":"Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study","volume":"23","author":"Gardner","year":"2015","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R25-20230928","author":"Allain"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201812000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T18:49:58Z","timestamp":1775242198000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201812000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":25,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001324","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2018,12]]}}}