{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T19:33:26Z","timestamp":1793907206212,"version":"4.8.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Fixation of young femoral neck fractures represents a challenge in the field of orthopaedic trauma surgery. Conventional methods, including cannulated screw and sliding hip screw constructs, have been studied and found to have similar results with regards to patient outcomes, which has made choosing an optimum fixation strategy difficult. In all of these cases, quality of reduction has been shown to be the most important factor when it comes to creating a favorable environment for fracture healing. Some of these patients, however, continue to have negative sequelae including nonunion, avascular necrosis, femoral head collapse, and poor hip function as a result. In this article, we review the 2 most commonly used constructs and present 2 novel fixation constructs for the fixation of femoral neck fractures in physiologically young patients, including the Smith &amp; Nephew Conquest system and the Aesculap Targon system. We outline techniques for usage of these systems and proposed advantages to these systems compared with conventional fixation methods. We also discuss the results of previously published studies regarding conventional fixation methods and compare with some limited studies that have been published on these newer technologies.<\/jats:p>","DOI":"10.1097\/bot.0000000000001367","type":"journal-article","created":{"date-parts":[[2018,12,12]],"date-time":"2018-12-12T19:47:36Z","timestamp":1544644056000},"page":"S20-S26","source":"Crossref","is-referenced-by-count":51,"title":["Technologies for Young Femoral Neck Fracture Fixation"],"prefix":"10.1097","volume":"33","author":[{"given":"Matthew","family":"Duffin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Holly T.","family":"Pilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","first-page":"101","article-title":"A brief history of internal fixation of femoral neck fracture","volume":"44","author":"Mei","year":"2014","journal-title":"Zhonghua Yi Shi Za Zhi."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.2106\/00004623-200408000-00015","article-title":"Femoral neck fractures in patients between the ages of fifteen and fifty years","volume":"86-A","author":"Haidukewych","year":"2004","journal-title":"J Bone Joint Surg."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","article-title":"Complications following young femoral neck fractures","volume":"46","author":"Slobogean","year":"2015","journal-title":"Injury."},{"key":"R4-20230828","first-page":"673","article-title":"Influence of number and orientation of screws on stability in the internal fixation of unstable femoral neck fractures","volume":"48","author":"Gumustas","year":"2014","journal-title":"Acta Orthop Traumatol."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1302\/0301-620X.87B5.15237","article-title":"The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing","volume":"87","author":"Gurusamy","year":"2005","journal-title":"J Bone Joint Surg."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"1793","DOI":"10.2106\/00004623-199412000-00005","article-title":"Intracapsular fractures of the femoral neck","volume":"76","author":"Asnis","year":"1994","journal-title":"J Bone Joint Surg."},{"key":"R7-20230828","first-page":"10","article-title":"The use of cannulated screws in musculoskeletal trauma. A review of surgical techniques","author":"Moehring","year":"1994","journal-title":"Orthop Rev."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1097\/00005131-200006000-00002","article-title":"Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates","volume":"14","author":"McLouglin","year":"2000","journal-title":"J Orthop Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","article-title":"The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip","volume":"77","author":"Baumgaertner","year":"1995","journal-title":"J Bone Joint Surg Am."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1097\/00005131-200407000-00006","article-title":"A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation","volume":"18","author":"Sommers","year":"2004","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.cjtee.2015.11.021","article-title":"Comparative study of multiple cancellous screws versus sliding hip screws in femoral neck fractures of young adults","volume":"19","author":"Gupta","year":"2016","journal-title":"Chin J Traumatol."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.ijsu.2018.01.050","article-title":"Sliding hip screw versus cannulated cancellous screws for fixation of femoral neck fractures in adults: a systematic review","volume":"52","author":"Ma","year":"2018","journal-title":"Int J Surg."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.injury.2014.12.031","article-title":"Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly","volume":"46","author":"Panteli","year":"2015","journal-title":"Injury."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1016\/S0140-6736(17)30066-1","article-title":"Fracture fixation in the operative management of hip fractures (FAITH): an international, multicenter, randomized controlled trial","volume":"389","year":"2017","journal-title":"Lancet."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"22","DOI":"10.4055\/cios.2015.7.1.22","article-title":"The Targon FN system for the management of intracapsular neck of femur fractures: minimum 2-year experience and outcome in an independent hospital","volume":"7","author":"Osarumwense","year":"2015","journal-title":"Clin Orthop Surg."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"212","DOI":"10.3109\/17453678709146468","article-title":"Fixation of displaced femoral neck fractures: a comparison between sliding screw plate and four cancellous bone screws","volume":"58","author":"Madsen","year":"1987","journal-title":"Acta Orthop Scand."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.injury.2009.09.004","article-title":"Internal fixation of intracapsular hip fractures with a dynamic locking plate: initial experience and results for 83 patients treated with a new implant","volume":"41","author":"Parker","year":"2010","journal-title":"Injury."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/01.blo.0000119459.00792.c1","article-title":"Undisplaced intracapsular hip fractures: results of internal fixation in 375 patients","volume":"421","author":"Conn","year":"2004","journal-title":"Clin Orthop Relat Res."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/S0020-1383(16)30854-3","article-title":"Clinical results of surgical treatment for femoral neck fractures with the Targon FN","volume":"47","author":"Takigawa","year":"2016","journal-title":"Injury."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"138","DOI":"10.3109\/17453679809117614","article-title":"Choice of implant for internal fixation of femoral neck fractures: meta-analysis of 25 randomised trials including 4925 patients","volume":"69","author":"Parker","year":"1998","journal-title":"Acta Orthop Scand."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/BOT.0b013e3182a225fa","article-title":"Osteosynthesis of unstable intracapsular femoral neck fracture by dynamic locking plate or screw fixation: early results","volume":"28","author":"Thein","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.injury.2013.10.026","article-title":"Angular stable multiple screw fixation (Targon\u2122 FN) versus standard SHS for the fixation of femoral neck fractures","volume":"45","author":"Eschler","year":"2014","journal-title":"Injury."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201901001-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:51:26Z","timestamp":1693205486000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201901001-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001367","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]}}}