{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T07:31:04Z","timestamp":1769153464306,"version":"3.49.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To describe the surgical technique and clinical outcomes of high-energy proximal femur fractures treated with a 95-degree angled blade plate.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective case series.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Single academic Level I trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient\/Participants:<\/jats:title>\n            <jats:p>Forty-five consecutive patients from March 2012 to April 2017 who sustained a high-energy, unstable proximal femur fracture including (OTA\/AO 31-A1, 31-A2, 31-A3, 31-B3, 32-A1a, and 32-C3i).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Open reduction internal fixation with a 95-degree angled blade plate used in conjunction with an articulated tensioning device.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Nonunion, malunion, secondary operations, and postoperative infection.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Twenty six patients were available for follow-up. The mean age was 43.8 (range 22\u201386) years, and 81% (21\/26) were men. The most common fracture pattern was OTA\/AO 31-A3.3. Two fractures were open. The articulated tensioner was used in 100% of cases. Average clinical follow-up was 19.2 (range 7\u201340) months. Twenty-four of 26 patients (92%) achieved osseous union after the index procedure. One patient underwent nonunion repair, and 2 patients had the blade plate removed as it was symptomatic laterally. No other secondary procedures were performed, and no instances of implant failure were seen. No patients had evidence of a superficial or deep infection.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>We found that high-energy proximal femur fractures treated with a 95-degree condylar blade plate and articulated tensioning device had a high rate of union with minimal postoperative complications. Although intramedullary nailing of these fractures remains a preferred treatment modality, the angled blade plate with articulated tensioning device is an excellent option to restore anatomical alignment and obtain bony union in certain highly comminuted fracture patterns.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001505","type":"journal-article","created":{"date-parts":[[2019,5,16]],"date-time":"2019-05-16T11:32:29Z","timestamp":1558006349000},"page":"335-340","source":"Crossref","is-referenced-by-count":11,"title":["Ninety-Five Degree Angled Blade Plate Fixation of High-Energy Unstable Proximal Femur Fractures Results in High Rates of Union and Minimal Complications"],"prefix":"10.1097","volume":"33","author":[{"given":"Marschall B.","family":"Berkes","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Washington University in St Louis School of Medicine, St. Louis, MO;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick C.","family":"Schottel","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, University of Vermont Larner College of Medicine, Burlington, VT;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew","family":"Weldon","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, Houston, TX; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denise H.","family":"Hansen","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, Houston, TX."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy S.","family":"Achor","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, Houston, TX."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"113","DOI":"10.5371\/hp.2017.29.2.113","article-title":"Clinical results of complex subtrochanteric femoral fractures with long cephalomedullary hip nail","volume":"29","author":"Kim","year":"2017","journal-title":"Hip Pelvis."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/BOT.0000000000001038","article-title":"Is the best plate a nail? A review of 3230 unstable intertrochanteric fractures of the proximal femur","volume":"32","author":"Tucker","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/BOT.0000000000000652","article-title":"Controversies in intramedullary fixation for intertrochanteric hip fractures","volume":"30","author":"Baldwin","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"3647","DOI":"10.1007\/s11999-015-4469-5","article-title":"Which fixation device is preferred for surgical treatment of intertrochanteric hip fractures in the United States? A survey of orthopaedic surgeons","volume":"473","author":"Niu","year":"2015","journal-title":"Clin Orthop Relat Res."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1097\/BOT.0b013e3181a2a31d","article-title":"A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model","volume":"23","author":"Crist","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/BOT.0b013e3181b04835","article-title":"Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures","volume":"23","author":"Floyd","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1080\/17453674.2017.1304207","article-title":"Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate","volume":"88","author":"Viberg","year":"2017","journal-title":"Acta Orthop."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1097\/01.bot.0000435629.86640.6f","article-title":"Short-term follow-up of pertrochanteric fractures treated using the proximal femoral locking plate","volume":"28","author":"Johnson","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e318251930d","article-title":"Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures","volume":"27","author":"Streubel","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/BOT.0b013e3181e31ccc","article-title":"Failure of proximal femoral locking compression plate: a case series","volume":"25","author":"Glassner","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.injury.2013.02.020","article-title":"High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate","volume":"44","author":"Wirtz","year":"2013","journal-title":"Injury."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1097\/BOT.0000000000000602","article-title":"Unstable proximal femur fractures treated with proximal femoral locking plates: a retrospective, multicenter study of 111 cases","volume":"30","author":"Collinge","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1007\/s00402-010-1074-7","article-title":"Fixation failure of the LCP proximal femoral plate 4.5\/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur","volume":"130","author":"Wieser","year":"2010","journal-title":"Arch Orthop Trauma Surg."},{"issue":"suppl 1","key":"R14-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and Dislocation Classification Compendium-2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/00003086-198901000-00019","article-title":"Subtrochanteric fractures of the femur. Results of treatment with the 95 degrees condylar blade-plate","volume":"238","author":"Kinast","year":"1989","journal-title":"Clin Orthop Relat Res."},{"issue":"suppl 3","key":"R16-20230828","doi-asserted-by":"crossref","first-page":"C7","DOI":"10.1016\/S0020-1383(98)95003-3","article-title":"Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures","volume":"29","author":"Siebenrock","year":"1998","journal-title":"Injury."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1097\/01.bot.0000184141.52330.5e","article-title":"Treatment of unstable peritrochanteric femoral fractures using a 95 degrees angled blade plate","volume":"19","author":"Yoo","year":"2005","journal-title":"J Orthop Trauma."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"15","DOI":"10.5606\/ehc.2014.04","article-title":"A comparison of proximal femoral locking plate versus 95-degree angled blade plate in the treatment of reverse intertrochanteric fractures","volume":"25","author":"Azboy","year":"2014","journal-title":"Eklem Hast Cerrahisi."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/BOT.0000000000001008","article-title":"Biomechanical analysis of the proximal femoral locking compression plate: do quality of reduction and screw orientation influence construct stability?","volume":"32","author":"Zderic","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/BOT.0b013e3182254ea3","article-title":"A biomechanical comparison of a locking plate, a nail, and a 95 degrees angled blade plate for fixation of subtrochanteric femoral fractures","volume":"26","author":"Forward","year":"2012","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00005131-201907000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:08:38Z","timestamp":1693206518000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00005131-201907000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":20,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001505","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2019,7]]}}}