{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T05:17:11Z","timestamp":1794374231098,"version":"4.9.0"},"reference-count":40,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Radial head fractures are common injuries comprising 1\/3 of the fractures about the elbow. As a secondary valgus stabilizer of the elbow, radial head fractures can compromise elbow stability leading to long-term pain, dysfunction, and degenerative change. Furthermore, radial head fractures can be accompanied by associated injuries including ligamentous lesions that can further exacerbate elbow instability, leading to long-term sequelae. As fixation principles and technology have evolved, so has the ability to render surgical treatment for these fractures. In general, minimally displaced and some displaced fractures may be treated nonoperatively with early motion. Fractures with a block to rotation and displaced fragments with 3 or fewer fragments may be treated with open reduction and internal fixation. Comminuted fractures or those with greater than 3 fragments may be successfully treated with radial head replacement. Associated elbow instability will also influence treatment decisions.<\/jats:p>","DOI":"10.1097\/bot.0000000000001641","type":"journal-article","created":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T12:55:15Z","timestamp":1572958515000},"page":"S1-S6","source":"Crossref","is-referenced-by-count":12,"title":["Indications and Clinical Results of Radial Head Replacement: Has Anything Changed?"],"prefix":"10.1097","volume":"33","author":[{"given":"Blake A.","family":"Eyberg","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael D.","family":"McKee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"954","DOI":"10.5312\/wjo.v6.i11.954","article-title":"Current concepts in the management of radial head fractures","volume":"6","author":"Kodde","year":"2015","journal-title":"World J Orthop."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1097\/01.blo.0000180606.30981.78","article-title":"Associated injuries complicating radial head fractures: a demographic study","volume":"441","author":"van Riet","year":"2005","journal-title":"Clin Orthop Relat Res."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.2106\/00004623-200408000-00018","article-title":"The effect of radial head excision and arthroplasty on elbow kinematics and stability","volume":"86","author":"Beingessner","year":"2004","journal-title":"J Bone Joint Surg Am."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1002\/bjs.18004217203","article-title":"Some observations on fractures of the head of the radius with a review of one hundred cases","volume":"42","author":"Mason","year":"1954","journal-title":"Br J Surg."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/0020-1383(87)90385-8","article-title":"Fractures of the radial head\u2014the benefit of aspiration: a prospective controlled trial","volume":"18","author":"Holdsworth","year":"1987","journal-title":"Injury."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/00005131-199103000-00004","article-title":"Open reduction and internal fixation of radial head fractures","volume":"5","author":"King","year":"1991","journal-title":"J Orthop Trauma."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.2106\/00004623-200210000-00011","article-title":"Open reduction and internal fixation of fractures of the radial head","volume":"84","author":"Ring","year":"2002","journal-title":"J Bone Joint Surg Am."},{"key":"R9-20230828","first-page":"1571","article-title":"Posterolateral rotatory instability of the elbow following radial head resection","volume":"87","author":"Hall","year":"2005","journal-title":"J Bone Joint Surg Am."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/0020-1383(81)90012-7","article-title":"Replacement of the radial head in the treatment of unstable elbow fractures","volume":"12","author":"Harrington","year":"1981","journal-title":"Injury."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/j.jse.2018.10.019","article-title":"Interventions for displaced radial head fractures: network meta-analysis of randomized trials","volume":"28","author":"Vannabouathong","year":"2019","journal-title":"J Shoulder Elbow Surg."},{"key":"R12-20230828","first-page":"360","article-title":"Artificial radial head replacement for the treatment of comminuted fractures of the radial head [in Chinese]","volume":"30","author":"Liu","year":"2017","journal-title":"Zhongguo Gu Shang."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00264-007-0453-3","article-title":"A comparative study of internal fixation and prosthesis replacement for radial head fractures of Mason type III","volume":"33","author":"Ruan","year":"2009","journal-title":"Int Orthop."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1302\/0301-620X.100B11.BJJ-2018-0293.R1","article-title":"Radial head resection versus prosthetic arthroplasty in terrible triad injury: a retrospective comparative cohort study: a retrospective comparative cohort study","volume":"100-B","author":"Mazhar","year":"2018","journal-title":"Bone Joint J."},{"key":"R15-20230828","doi-asserted-by":"crossref","DOI":"10.1002\/14651858.CD008987.pub2","article-title":"Surgical interventions for treating radial head fractures in adults","author":"Gao","year":"2013","journal-title":"Cochrane Database Syst Rev."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1007\/s00590-013-1367-y","article-title":"Open reduction and internal-fixation versus radial head replacement in treatment of Mason type III radial head fractures","volume":"24","author":"Li","year":"2014","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1111\/ans.13060","article-title":"Radial head replacement or repair for the terrible triad of the elbow: which procedure is better?","volume":"85","author":"Yan","year":"2015","journal-title":"ANZ J Surg."},{"key":"R18-20230828","first-page":"539","article-title":"Metallic cap replacement of radial head following fracture","volume":"59","author":"Carr","year":"1951","journal-title":"West J Surg Obstet Gynecol."},{"key":"R19-20230828","first-page":"40","article-title":"Long-term results of replacement of the head of the radius with a silastic prosthesis [in German]","volume":"86","author":"Borsky","year":"1993","journal-title":"Z Unfallchir Versicherungsmed."},{"key":"R20-20230828","first-page":"330","article-title":"A comparative study of the treatment of fractures of the radial head by resection or by Swanson silastic implant","volume":"34","author":"Berger","year":"1991","journal-title":"Ann Radiol (Paris)"},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"2136","DOI":"10.1007\/s11999-014-3516-y","article-title":"Radial head replacement for acute complex fractures: what are the rate and risks factors for revision or removal?","volume":"472","author":"Duckworth","year":"2014","journal-title":"Clin Orthop Relat Res."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1016\/S0363-5023(03)00426-X","article-title":"The noncircular shape of the radial head","volume":"28","author":"van Riet","year":"2003","journal-title":"J Hand Surg Am."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"1829","DOI":"10.2106\/00004623-200112000-00010","article-title":"Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow","volume":"83","author":"Pomianowski","year":"2001","journal-title":"J Bone Joint Surg Am."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.clinbiomech.2006.01.006","article-title":"The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint","volume":"21","author":"van Riet","year":"2006","journal-title":"Clin Biomech."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"2629","DOI":"10.2106\/00004623-200412000-00007","article-title":"Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow","volume":"86","author":"Van Glabbeek","year":"2004","journal-title":"J Bone Joint Surg Am."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.jse.2010.11.010","article-title":"Micromotion of plasma spray versus grit-blasted radial head prosthetic stem surfaces","volume":"20","author":"Chanlalit","year":"2011","journal-title":"J Shoulder Elbow Surg."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jse.2010.05.030","article-title":"Radial head prosthesis micromotion characteristics: partial versus fully grit-blasted stems","volume":"20","author":"Chanlalit","year":"2011","journal-title":"J Shoulder Elbow Surg."},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/j.jse.2009.02.014","article-title":"Stem diameter and micromotion of press fit radial head prosthesis: a biomechanical study","volume":"18","author":"Moon","year":"2009","journal-title":"J Shoulder Elbow Surg."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1097\/BOT.0000000000000885","article-title":"Radial head ingrowth anatomic implant versus smooth stem monoblock implant in acute terrible triad injury: a prospective comparative study","volume":"31","author":"Rodriguez-Quintana","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.jse.2018.07.032","article-title":"Does radial head implant fixation affect functional outcomes? A systematic review and meta-analysis","volume":"28","author":"Agyeman","year":"2019","journal-title":"J Shoulder Elbow Surg."},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1016\/j.jse.2018.08.043","article-title":"Timely recognition of total elbow and radial head arthroplasty adverse events: an analysis of reports to the US Food and Drug Administration","volume":"28","author":"Somerson","year":"2019","journal-title":"J Shoulder Elbow Surg."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.jse.2011.05.001","article-title":"Effect of hoop stress fracture on micromotion of textured ingrowth stems for radial head replacement","volume":"21","author":"Chanlalit","year":"2012","journal-title":"J Shoulder Elbow Surg."},{"key":"R33-20230828","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.jse.2017.09.037","article-title":"The effect of a radial neck notch on press-fit stem stability: a biomechanical study on 7 cadavers","volume":"27","author":"Shukla","year":"2018","journal-title":"J Shoulder Elbow Surg."},{"key":"R34-20230828","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.1016\/j.jse.2013.06.015","article-title":"Canal preparation for prosthetic radial head replacement: rasping versus reaming","volume":"22","author":"Shukla","year":"2013","journal-title":"J Shoulder Elbow Surg."},{"issue":"Pt 2","key":"R35-20230828","doi-asserted-by":"crossref","first-page":"250","DOI":"10.2106\/JBJS.J.00356","article-title":"Determination of correct implant size in radial head arthroplasty to avoid overlengthening: surgical technique","volume":"92","author":"Athwal","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"R36-20230828","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/s11999-013-3277-z","article-title":"Can ulnar variance be used to detect overstuffing after radial head arthroplasty?","volume":"472","author":"Moon","year":"2014","journal-title":"Clin Orthop Relat Res."},{"key":"R37-20230828","doi-asserted-by":"crossref","first-page":"527","DOI":"10.2106\/JBJS.15.00128","article-title":"Radial head fractures treated with modular metallic radial head replacement: outcomes at a mean follow-up of eight years","volume":"98","author":"Marsh","year":"2016","journal-title":"J Bone Joint Surg Am."},{"key":"R38-20230828","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1186\/s13018-018-0844-8","article-title":"Long-term outcomes of modular metal prosthesis replacement in patients with irreparable radial head fractures","volume":"13","author":"Chen","year":"2018","journal-title":"J Orthop Surg Res."},{"key":"R39-20230828","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1302\/0301-620X.99B9.BJJ-2016-1043.R2","article-title":"Mid-term outcomes of 77 modular radial head prostheses","volume":"99-B","author":"Laumonerie","year":"2017","journal-title":"Bone Joint J."},{"key":"R40-20230828","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1016\/j.jse.2017.04.008","article-title":"Retrospective cohort study on radial head replacements comparing results between smooth and porous stem designs","volume":"26","author":"Laflamme","year":"2017","journal-title":"J Shoulder Elbow Surg."},{"key":"R41-20230828","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1016\/j.jse.2016.02.007","article-title":"Press-fit bipolar radial head arthroplasty, midterm results","volume":"25","author":"Kodde","year":"2016","journal-title":"J Shoulder Elbow Surg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001641","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:43:53Z","timestamp":1693205033000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001641"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":40,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001641","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2019,12]]}}}