{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T14:22:51Z","timestamp":1773411771392,"version":"3.50.1"},"reference-count":55,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Summary:<\/jats:title><jats:p>The number of fragility fractures is rising, and treatment is a challenge for orthopaedic trauma surgeons. Various augmentation options have been developed to prevent mechanical failure. Different composites can be used based on the fracture type, patient needs, and biomechanical needs. Indications for augmentation are not limited to osteoporotic fractures but can also be performed as a salvage procedure or in pathologic fractures. Biomechanical studies have shown advantages for augmented implants in the spine, proximal femur, and humerus. Clinical studies are preliminary but promising, showing good clinical results after augmentation with reduced mechanical failure and minimal complications.<\/jats:p>","DOI":"10.1097\/bot.0000000000001643","type":"journal-article","created":{"date-parts":[[2019,11,5]],"date-time":"2019-11-05T12:55:15Z","timestamp":1572958515000},"page":"S21-S26","source":"Crossref","is-referenced-by-count":22,"title":["Osteoporotic Bone: When and How to Use Augmentation?"],"prefix":"10.1097","volume":"33","author":[{"given":"Konrad","family":"Schuetze","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Eickhoff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Goetz","family":"R\u00f6derer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florian","family":"Gebhard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter H.","family":"Richter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"2520","DOI":"10.1002\/jbmr.2269","article-title":"The recent prevalence of osteoporosis and low bone mass in the United States based on bone mineral density at the femoral neck or lumbar spine","volume":"29","author":"Wright","year":"2014","journal-title":"J Bone Miner Res."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1359\/jbmr.061113","article-title":"Incidence and economic burden of osteoporosis-related fractures in the United States, 2005\u20132025","volume":"22","author":"Burge","year":"2007","journal-title":"J Bone Miner Res."},{"issue":"suppl 2","key":"R3-20230828","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1016\/S0020-1383(16)47002-6","article-title":"Failure of fracture fixation in osteoporotic bone","volume":"47","author":"R\u00fcden von","year":"2016","journal-title":"Injury."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1302\/0301-620X.72B1.2298790","article-title":"Intertrochanteric femoral fractures. Mechanical failure after internal fixation","volume":"72","author":"Davis","year":"1990","journal-title":"J Bone Joint Surg Br."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1007\/s00113-007-1248-0","article-title":"\u201cCutting out\u201d in pertrochanteric fractures\u2014problem of osteoporosis?","volume":"110","author":"Bonnaire","year":"2007","journal-title":"Unfallchirurg."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","article-title":"A systematic review of locking plate fixation of proximal humerus fractures","volume":"42","author":"Sproul","year":"2011","journal-title":"Injury."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1007\/s00198-007-0515-9","article-title":"Influence of osteoporosis on fracture fixation\u2014a systematic literature review","volume":"19","author":"Goldhahn","year":"2008","journal-title":"Osteoporos Int."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"108","DOI":"10.4103\/ortho.IJOrtho_243_17","article-title":"Complications associated with locking plate of proximal humerus fractures","volume":"52","author":"Kavuri","year":"2018","journal-title":"Indian J Orthop."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1471-2474-14-1","article-title":"Critical factors in cut-out complication after gamma nail treatment of proximal femoral fractures","volume":"14","year":"2013","journal-title":"BMC Musculoskelet Disord."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1097\/00005373-200107000-00012","article-title":"The standard Gamma nail: a critical analysis of 1,000 cases","volume":"51","author":"Kukla","year":"2001","journal-title":"J Trauma."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/01.bot.0000151819.95075.ad","article-title":"Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail","volume":"19","author":"Utrilla","year":"2005","journal-title":"J Orthop Trauma."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1302\/0301-620X.82B6.0820864","article-title":"The cost and implications of reoperation after surgery for fracture of the hip","volume":"82","author":"Palmer","year":"2000","journal-title":"J Bone Joint Surg Br."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1136\/bmj.38643.663843.55","article-title":"Effect of comorbidities and postoperative complications on mortality after hip fracture in elderly people: prospective observational cohort study","volume":"331","author":"Roche","year":"2005","journal-title":"BMJ."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1007\/s00586-018-5660-7","article-title":"Time to augment?! Impact of cement augmentation on pedicle screw fixation strength depending on bone mineral density","volume":"27","author":"Weiser","year":"2018","journal-title":"Eur Spine J."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"2230","DOI":"10.1002\/jor.20299","article-title":"Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures","volume":"24","author":"Linden von der","year":"2006","journal-title":"J Orthop Res."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/j.injury.2013.05.008","article-title":"Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures","volume":"44","author":"R\u00f6derer","year":"2013","journal-title":"Injury."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/j.injury.2015.04.020","article-title":"How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data","volume":"46","author":"Schliemann","year":"2015","journal-title":"Injury."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1016\/j.spinee.2015.03.016","article-title":"The biomechanics of pedicle screw augmentation with cement","volume":"15","author":"Benjamin","year":"2015","journal-title":"Spine J."},{"key":"R19-20230828","first-page":"484","article-title":"Proximal cut-out of the hip screw: cement augmentation as a minimally invasive rescue procedure","volume":"150","author":"Ackermann","year":"2012","journal-title":"Z Orthop Unfall."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"e154","DOI":"10.1308\/rcsann.2018.0076","article-title":"A novel use of cement as a salvage procedure in patients with complex spinal injuries with proximal junctional failure","volume":"100","author":"Divani","year":"2018","journal-title":"Ann R Coll Surg Engl."},{"key":"R21-20230828","first-page":"441","article-title":"Tibiotalocalcaneal fusion with a cemented coated retrograde nail as a salvage procedure for infected ORIF of the ankle","volume":"61","author":"Herrera-P\u00e9rez","year":"2017","journal-title":"Rev Esp Cir Ortop Traumatol."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"1577","DOI":"10.1007\/s00402-012-1579-3","article-title":"Is augmentation a possible salvage procedure after lateral migration of the proximal femur nail antirotation?","volume":"132","author":"Erhart","year":"2012","journal-title":"Arch Orthop Trauma Surg."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"232","DOI":"10.2174\/1874325001408010232","article-title":"The PFNA\u00ae augmented in revision surgery of proximal femur fractures","volume":"8","author":"Scola","year":"2014","journal-title":"Open Orthop J."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.suronc.2015.05.003","article-title":"Minimally invasive surgery for femoral neck fractures using bone cement infusible hollow-perforated screw in high-risk patients with advanced cancer","volume":"24","author":"Lin","year":"2015","journal-title":"Surg Oncol."},{"key":"R25-20230828","first-page":"144","article-title":"Intramedullary nailing without curettage and cement augmentation for the treatment of impending and complete pathological fractures of the proximal or midshaft femur","volume":"80","author":"Shemesh","year":"2014","journal-title":"Acta Orthop Belg."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.injury.2013.09.025","article-title":"Intramedullary nailing for treatment of pathologic femoral fractures due to metastases","volume":"45","author":"Piccioli","year":"2014","journal-title":"Injury."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/S0748-7983(96)92450-6","article-title":"Treatment of pathological fractures of the humeral shaft due to bone metastases: a comparison of intramedullary locking nail and plate osteosynthesis with adjunctive bone cement","volume":"22","author":"Dijkstra","year":"1996","journal-title":"Eur J Surg Oncol."},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/00003086-199002000-00036","article-title":"Metastatic bone disease: a study of the surgical treatment of 166 pathologic humeral and femoral fractures","volume":"251","author":"Yazawa","year":"1990","journal-title":"Clin Orthop Relat Res."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1302\/0301-620X.92B5.23246","article-title":"Pathological fractures of the proximal humerus treated with a proximal humeral locking plate and bone cement","volume":"92","author":"Siegel","year":"2010","journal-title":"J Bone Joint Surg Br."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1097\/00005373-200212000-00012","article-title":"The use of BoneSource hydroxyapatite cement for traumatic metaphyseal bone void filling","volume":"53","author":"Dickson","year":"2002","journal-title":"J Trauma."},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1186\/s12891-015-0574-6","article-title":"Augmentation of tibial plateau fractures with an injectable bone substitute: CERAMENT\u2122: three year follow-up from a prospective study","volume":"16","author":"Iundusi","year":"2015","journal-title":"BMC Musculoskelet Disord."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/00003086-198903000-00008","article-title":"Interporous hydroxyapatite as a bone graft substitute in tibial plateau fractures","volume":"240","author":"Bucholz","year":"1989","journal-title":"Clin Orthop Relat Res."},{"key":"R33-20230828","first-page":"656","article-title":"Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies","volume":"44","author":"Biermann","year":"2019","journal-title":"Arch Orthop Trauma Surg."},{"key":"R34-20230828","first-page":"1697","article-title":"Cement augmentation of the proximal humerus internal locking system in elderly patients: a multicenter randomized controlled trial","volume":"38","author":"Hengg","year":"2019","journal-title":"Arch Orthop Trauma Surg."},{"key":"R35-20230828","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s00402-013-1902-7","article-title":"Long-term results of the augmented PFNA: a prospective multicenter trial","volume":"134","author":"Kammerlander","year":"2013","journal-title":"Arch Orthop Trauma Surg."},{"key":"R36-20230828","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1302\/0301-620X.89B7.19148","article-title":"The role of polymethylmethacrylate bone cement in modern orthopaedic surgery","volume":"89","author":"Webb","year":"2007","journal-title":"J Bone Joint Surg Br."},{"key":"R37-20230828","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s40824-019-0157-y","article-title":"Review of bone graft and bone substitutes with an emphasis on fracture surgeries","volume":"23","author":"Sohn","year":"2019","journal-title":"Biomater Res."},{"key":"R38-20230828","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1097\/00006534-197905000-00005","article-title":"Experimental evaluation of ceramic calcium phosphate as a substitute for bone grafts","volume":"63","author":"Ferraro","year":"1979","journal-title":"Plast Reconstr Surg."},{"key":"R39-20230828","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/BF03261883","article-title":"Recommendations and considerations for the use of biologics in orthopedic surgery","volume":"26","author":"Zwingenberger","year":"2012","journal-title":"BioDrugs."},{"key":"R40-20230828","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1002\/jor.1100050307","article-title":"The evaluation of a biphasic calcium phosphate ceramic for use in grafting long-bone diaphyseal defects","volume":"5","author":"Moore","year":"1987","journal-title":"J Orthop Res."},{"key":"R41-20230828","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1002\/jbm.820230806","article-title":"Transformation of biphasic calcium phosphate ceramics in vivo: ultrastructural and physicochemical characterization","volume":"23","author":"Daculsi","year":"1989","journal-title":"J Biomed Mater Res."},{"key":"R42-20230828","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1007\/s10856-007-3252-x","article-title":"The thermal stability of hydroxyapatite in biphasic calcium phosphate ceramics","volume":"19","author":"Nilen","year":"2008","journal-title":"J Mater Sci Mater Med."},{"key":"R43-20230828","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1016\/j.injury.2010.08.009","article-title":"Predictive factors for cutting-out in femoral intramedullary nailing","volume":"41","author":"Lobo-Escolar","year":"2010","journal-title":"Injury."},{"key":"R44-20230828","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1016\/j.injury.2013.03.003","article-title":"Cement augmentation of the proximal femoral nail antirotation for the treatment of osteoporotic pertrochanteric fractures\u2014a biomechanical cadaver study","volume":"44","author":"Fensky","year":"2013","journal-title":"Injury."},{"key":"R45-20230828","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1007\/s00113-015-0051-6","article-title":"Augmentation techniques on the proximal femur [in German]","volume":"118","author":"Neuerburg","year":"2015","journal-title":"Unfallchirurg."},{"key":"R46-20230828","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","article-title":"Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis","volume":"23","author":"Brunner","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R47-20230828","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1097\/BOT.0b013e3181ccafb3","article-title":"Clinical results for minimally invasive locked plating of proximal humerus fractures","volume":"24","author":"R\u00f6derer","year":"2010","journal-title":"J Orthop Trauma."},{"key":"R48-20230828","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1016\/j.injury.2012.07.003","article-title":"The effect of in situ augmentation on implant anchorage in proximal humeral head fractures","volume":"43","author":"Unger","year":"2012","journal-title":"Injury."},{"key":"R49-20230828","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s11678-018-0440-x","article-title":"Cement augmentation of humeral head screws reduces early implant-related complications after locked plating of proximal humeral fractures","volume":"13","author":"Katthagen","year":"2018","journal-title":"Obere Extrem."},{"key":"R50-20230828","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.jse.2011.09.017","article-title":"Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures","volume":"21","author":"Egol","year":"2012","journal-title":"J Shoulder Elbow Surg."},{"issue":"19 suppl","key":"R51-20230828","doi-asserted-by":"crossref","first-page":"S144","DOI":"10.1097\/01.brs.0000236893.65878.39","article-title":"Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65: surgical considerations and treatment options in patients with poor bone quality","volume":"31","author":"DeWald","year":"2006","journal-title":"Spine."},{"key":"R52-20230828","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s00586-015-3904-3","article-title":"Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading","volume":"26","author":"Bostelmann","year":"2017","journal-title":"Eur Spine J."},{"key":"R53-20230828","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1007\/s00068-013-0310-6","article-title":"Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly","volume":"39","author":"Saman El","year":"2013","journal-title":"Eur J Trauma Emerg Surg."},{"key":"R54-20230828","doi-asserted-by":"crossref","first-page":"E28","DOI":"10.1097\/BSD.0b013e318228bbed","article-title":"Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients","volume":"25","author":"Sawakami","year":"2012","journal-title":"J Spinal Disord Tech."},{"issue":"6 suppl 1","key":"R55-20230828","first-page":"71","article-title":"Polymethylmethacrylate-augmented fenestreted pedicle-screw fixation in low bone quality patients: a case series and literature review","volume":"32","author":"Ghermandi","year":"2018","journal-title":"J Biol Regul Homeost Agents."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001643","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T14:01:46Z","timestamp":1695391306000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001643"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":55,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001643","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2019,12]]}}}