{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,20]],"date-time":"2024-07-20T08:29:25Z","timestamp":1721464165287},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To evaluate a noninvasive hemoglobin measurement device in an orthopaedic trauma population.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>One hundred five patients consecutively admitted to the orthopaedic trauma service after surgical treatment of fracture.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Transcutaneous hemoglobin (TcHgb) monitoring using the Masimo Pronto Pulse CO-Oximeter model with Rainbow SET Technology for spot TcHgb measurement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>TcHgb measurements and standard venipuncture hemoglobin (vHgb) were obtained. Patient preferences for each were recorded.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>TcHgb measurements were obtained in 100 patients and compared with their corresponding vHgb measurements. The mean vHgb and TcHgb were 10.2 \u00b1 1.9 g\/dL and 11.2 \u00b1 2.1 g\/dL, respectively, and the mean difference was 1.1 \u00b1 1.6 g\/dL, which was statistically different from 0 (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). In 76% of cases, the TcHgb device overestimated vHgb. In a subgroup of patients undergoing procedures with minimal expected blood loss (external fixators of knee or ankle, irrigation and debridement, or open reduction and internal fixation of ankle or calcaneal fractures), the mean difference between vHgb and TcHgb was 0.68 \u00b1 1.6 g\/dL (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.06).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>A preliminary study of TcHgb monitoring with the tested device as a potential screening mechanism to limit unnecessary blood draws showed statistical difference from vHgb; however, the mean bias 1.1 g\/dL of hemoglobin was notably small. In a subgroup of patients undergoing procedures with minimal expected blood loss, the device may have merit. Larger studies are required to determine the clinical relevance of differences in measurements between the 2 methods.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001677","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T19:23:30Z","timestamp":1572895410000},"page":"e165-e169","source":"Crossref","is-referenced-by-count":1,"title":["Transcutaneous Hemoglobin Screening in an Adult Orthopaedic Trauma Population"],"prefix":"10.1097","volume":"34","author":[{"given":"Alexander S.","family":"Rascoe","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael D.","family":"Kavanagh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary A.","family":"Breslin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emily","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heather A.","family":"Vallier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/01.blo.0000072469.32680.b6","article-title":"Revision total hip arthroplasty: hospital cost and reimbursement analysis","volume":"413","author":"Crowe","year":"2003","journal-title":"Clin Orthop Relat Res."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1097\/01.blo.0000246567.88585.0a","article-title":"Success of clinical pathways for total joint arthroplasty in a community hospital","volume":"457","author":"Walter","year":"2007","journal-title":"Clin Orthop Relat Res."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.arth.2016.05.001","article-title":"Physicians with defined clear care pathways have better discharge disposition and lower cost","volume":"31","author":"Tessier","year":"2016","journal-title":"J Arthroplasty."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"349","DOI":"10.2106\/JBJS.O.00820","article-title":"Noninvasive hemoglobin monitoring","volume":"98","author":"Martin","year":"2016","journal-title":"J Bone Joint Surg."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"2084","DOI":"10.1016\/j.arth.2014.06.029","article-title":"Utility of noninvasive transcutaneous measurement of postoperative hemoglobin in total joint arthroplasty patients","volume":"29","author":"Stoesz","year":"2014","journal-title":"J Arthroplasty."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.jamcollsurg.2014.09.022","article-title":"Transforming hemoglobin measurement in trauma patients: noninvasive spot check hemoglobin","volume":"220","author":"Joseph","year":"2015","journal-title":"J Am Coll Surg."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1097\/CCM.0b013e3182227e2d","article-title":"Accuracy of a continuous non-invasive hemoglobin monitor in intensive care unit patients","volume":"39","author":"Frasca","year":"2011","journal-title":"Crit Care Med."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"1396","DOI":"10.1213\/ANE.0b013e318230b425","article-title":"Continuous noninvasive hemoglobin monitoring during complex spine surgery","volume":"113","author":"Berkow","year":"2011","journal-title":"Anesth Analg."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1213\/ANE.0b013e3181fc74b9","article-title":"The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution","volume":"111","author":"Macknet","year":"2010","journal-title":"Anesth Analg."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1213\/ANE.0b013e31820eecd1","article-title":"A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery","volume":"112","author":"Miller","year":"2011","journal-title":"Anesth Analg."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"e30065","DOI":"10.1371\/journal.pone.0030065","article-title":"Non-invasive measurement of hemoglobin: assessment of two different point-of-care technologies","volume":"7","author":"Gayat","year":"2012","journal-title":"PLoS One."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1213\/ANE.0000000000000272","article-title":"Accuracy of continuous noninvasive hemoglobin monitoring","volume":"119","author":"Kim","year":"2014","journal-title":"Anesth Analg."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/s00431-015-2602-9","article-title":"Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children\u2014a method comparison study","volume":"175","author":"Bhat","year":"2016","journal-title":"Eur J Pediatr."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/j.jclinane.2014.04.012","article-title":"Effects of thermoregulatory vasoconstriction on pulse hemoglobin measurements using a co-oximeter in patients undergoing surgery","volume":"26","author":"Yamaura","year":"2014","journal-title":"J Clin Anesth."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s10877-015-9816-2","article-title":"Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients","volume":"31","author":"Baulig","year":"2017","journal-title":"J Clin Monit Comput."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1093\/bja\/aer373","article-title":"Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section","volume":"108","author":"Butwick","year":"2012","journal-title":"Br J Anaesth."},{"issue":"3 suppl 2","key":"R17-20230828","doi-asserted-by":"crossref","first-page":"S134","DOI":"10.1097\/TA.0000000000000326","article-title":"Accuracy of noninvasive hemoglobin monitoring in patients at risk for hemorrhage","volume":"77","author":"Tsuei","year":"2014","journal-title":"J Trauma Acute Care Surg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001677","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:16:02Z","timestamp":1693206962000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001677"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5]]},"references-count":17,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001677","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,5]]}}}