{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T04:04:24Z","timestamp":1792728264196,"version":"4.5.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,4]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To compare the clinical and radiographic outcomes between patients treated with fibula allograft-augmented locking compression fixation and patients treated with locking compression fixation alone for 2- and 3-part proximal humeral fractures with varus displacement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective review.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>One hundred two patients treated with locking plate fixation \u00b1 fibular allograft augmentation confirmed intraoperatively by visual inspection to have varus-angulated, 2- and 3-part proximal humerus fractures with at least 45 degrees of varus angulation at the neck\/shaft and at least 1 cm of displacement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Proximal humerus locking plate (PHILOS; Synthes, Paoli, PA) with or without fibula allograft augmentation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Statistical analysis to determine the differences between fractures treated with locking compression fixation \u00b1 fibula allograft augmentation regarding complications, shoulder reported outcome measures, and patient ROMs (Visual Analog Score (VAS), Disabilities of the Arm, Shoulder and Hand, and Simple Shoulder Test scores). Medical comorbidities as potential risk factors for complication from surgery were also evaluated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of 102 surgical cases, 27 were augmented with fibula allograft and 75 were not. Postoperatively, there were 16 noncatastrophic varus collapses of the fracture, 6 catastrophic varus collapses, and 5 deaths. Addition of fibula allograft did not significantly affect postoperative varus collapse, shoulder ROM, pain, or PROMs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Addition of fibula allograft to patients sustaining varus-angulated, 2- and 3-part proximal humeral fractures conferred no benefit to patient outcomes at our institution.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001679","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T19:23:30Z","timestamp":1572895410000},"page":"186-192","source":"Crossref","is-referenced-by-count":26,"title":["Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation"],"prefix":"10.1097","volume":"34","author":[{"given":"Stephen","family":"Davids","sequence":"first","affiliation":[{"name":"College of Nursing and Health Sciences, University of Vermont, Burlington, VT;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dexter","family":"Allen","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Larner College of Medicine, University of Vermont, Burlington, VT; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Desarno","sequence":"additional","affiliation":[{"name":"University of Vermont Medical Biostatistics Unit, Burlington, VT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan K.","family":"Endres","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Larner College of Medicine, University of Vermont, Burlington, VT; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig","family":"Bartlett","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Larner College of Medicine, University of Vermont, Burlington, VT; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam","family":"Shafritz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Larner College of Medicine, University of Vermont, Burlington, VT; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: a review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1080\/00016470310017992","article-title":"Minimally displaced proximal humeral fractures: epidemiology and outcome in 507 cases","volume":"74","author":"Gaebler","year":"2003","journal-title":"Acta Orthop Scand."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1007\/s00402-009-0975-9","article-title":"Clinical and radiological evaluation of minimally displaced proximal humeral fractures","volume":"130","author":"Bahrs","year":"2010","journal-title":"Arch Orthop Trauma Surg."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jse.2007.07.016","article-title":"Functional outcome following one-part proximal humeral fractures: a prospective study","volume":"17","author":"Tejwani","year":"2008","journal-title":"J Shoulder Elbow Surg."},{"key":"R5-20230828","first-page":"CD000434","article-title":"Interventions for treating proximal humeral fractures in adults","volume":"12","author":"Handoll","year":"2012","journal-title":"Cochrane Database Syst Rev."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1001\/jama.2015.1629","article-title":"Surgical vs nonsurgical treatment of adults with displaced fractures of the proximal humerus: the PROFHER randomized clinical trial","volume":"313","author":"Rangan","year":"2015","journal-title":"JAMA."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"121","DOI":"10.2106\/JBJS.I.01505","article-title":"Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly","volume":"93","author":"Bell","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","article-title":"Analysis of efficacy and failure in proximal humerus fractures treated with locking plates","volume":"21","author":"Agudelo","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"233","DOI":"10.2106\/JBJS.F.01351","article-title":"Displacement\/screw cutout after open reduction and locked plate fixation of humeral fractures","volume":"90","author":"Owsley","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.1016\/j.injury.2015.05.017","article-title":"Midterm outcome and complications after minimally invasive treatment of displaced proximal humeral fractures in patients younger than 70 years using Humerusblock","volume":"46","author":"Tauber","year":"2015","journal-title":"Injury."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1080\/00016470410004120","article-title":"Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year","volume":"75","author":"Bjorkenheim","year":"2004","journal-title":"Acta Orthop Scand."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.injury.2011.04.003","article-title":"Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus","volume":"43","author":"Hardeman","year":"2012","journal-title":"Injury."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","article-title":"Predicting failure after surgical fixation of proximal humerus fractures","volume":"42","author":"Krappinger","year":"2011","journal-title":"Injury."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","article-title":"Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis","volume":"23","author":"Brunner","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","article-title":"The importance of medial support in locked plating of proximal humerus fractures","volume":"21","author":"Gardner","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/BOT.0b013e31815b3922","article-title":"Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant","volume":"22","author":"Gardner","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"3300","DOI":"10.1007\/s11999-011-1949-0","article-title":"Endosteal strut augment reduces complications associated with proximal humeral locking plates","volume":"469","author":"Neviaser","year":"2011","journal-title":"Clin Orthop Relat Res."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1016\/j.injury.2012.08.004","article-title":"Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus","volume":"43","author":"Matassi","year":"2012","journal-title":"Injury."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/j.jse.2014.10.019","article-title":"Geriatric proximal humeral fracture patients show similar clinical outcomes to non-geriatric patients after osteosynthesis with endosteal fibular strut allograft augmentation","volume":"24","author":"Hinds","year":"2015","journal-title":"J Shoulder Elbow Surg."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1186\/s13018-015-0258-9","article-title":"Clinical outcomes of allograft with locking compression plates for elderly four-part proximal humerus fractures","volume":"10","author":"Chen","year":"2015","journal-title":"J Orthop Surg Res."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1007\/s00264-015-2950-0","article-title":"Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft","volume":"40","author":"Panchal","year":"2016","journal-title":"Int Orthop."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.otsr.2015.12.021","article-title":"Comparison of intramedullary fibular allograft with locking compression plate versus shoulder hemi-arthroplasty for repair of osteoporotic four-part proximal humerus fracture: consecutive, prospective, controlled, and comparative study","volume":"102","author":"Chen","year":"2016","journal-title":"Orthop Traumatol Surg Res."},{"issue":"Suppl 10","key":"R23-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","article-title":"Fracture and dislocation classification compendium\u20142007: orthopaedic trauma association classification, database and outcomes committee","volume":"21","author":"Marsh","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L","article-title":"Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand)","volume":"29","author":"Hudak","year":"1996","journal-title":"Am J Ind Med."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001679","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:30:30Z","timestamp":1693207830000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001679"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001679","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,4]]}}}