{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T16:18:18Z","timestamp":1761581898223},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To evaluate interfragmentary motion over 1 year after distal femoral fracture fixation using radiostereometric analysis (RSA). The secondary aim was to assess whether RSA data are consistent with diagnoses of nonunion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level I urban trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients:<\/jats:title>\n            <jats:p>Sixteen patients between 22 and 89 years of age with distal femoral fracture (OTA\/AO type 33).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>All fractures were treated with a lateral locking plate, and tantalum markers were inserted into the main proximal and distal fracture fragments. RSA was performed at 2, 6, 12, 18, and 52 weeks postoperatively. Both unloaded and loaded RSA measurements were performed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Unloaded fracture migration over time and inducible micromotion at the fracture site in the coronal plane were determined at each follow-up interval.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>RSA precision in the coronal plane of interfragmentary motion over time and inducible micromotion were 1.2 and 0.9 mm in the coronal plane, respectively. Two cases required revision surgery for nonunion 1 year postoperatively. For cases of union, unloaded fracture migration stopped being detectable between 12 and 18 weeks, and inducible micromotion was no longer detectable by the 12-week visit. For cases of nonunion, both unloaded migration and inducible micromotion were detected throughout the study period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>RSA may be used to reliably assess distal femoral fracture healing. RSA revealed differences in cases of union and nonunion by 3 months and more consistently than traditional x-rays.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001684","type":"journal-article","created":{"date-parts":[[2019,12,3]],"date-time":"2019-12-03T19:13:07Z","timestamp":1575400387000},"page":"e60-e66","source":"Crossref","is-referenced-by-count":5,"title":["Radiostereometric Analysis of Stability and Inducible Micromotion After Locked Lateral Plating of Distal Femur Fractures"],"prefix":"10.1097","volume":"34","author":[{"given":"Vincent P.","family":"Galea","sequence":"first","affiliation":[{"name":"Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mina A.","family":"Botros","sequence":"additional","affiliation":[{"name":"Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael F.","family":"McTague","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Brigham and Women's Hospital, Boston, MA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Weaver","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Brigham and Women's Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark S.","family":"Vrahas","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henrik","family":"Malchau","sequence":"additional","affiliation":[{"name":"Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marilyn","family":"Heng","sequence":"additional","affiliation":[{"name":"Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Bragdon","sequence":"additional","affiliation":[{"name":"Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA;"},{"name":"Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1097\/00005131-200605000-00013","article-title":"Operative treatment of acute distal femur fractures: systematic review of 2 comparative studies and 45 case series (1989 to 2005)","volume":"20","author":"Zlowodzki","year":"2006","journal-title":"J Orthop Trauma."},{"issue":"suppl 3","key":"R2-20230828","doi-asserted-by":"crossref","first-page":"C62","DOI":"10.1016\/S0020-1383(00)80034-0","article-title":"The epidemiology of fractures of the distal femur","volume":"31","author":"Martinet","year":"2000","journal-title":"Injury."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1177\/2151458513496254","article-title":"Clinical outcomes of distal femoral fractures in the geriatric population using locking plates with a minimally invasive approach","volume":"4","author":"Doshi","year":"2013","journal-title":"Geriatr Orthop Surg Rehabil."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/1749-799X-8-43","article-title":"Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort","volume":"8","author":"Hoffmann","year":"2013","journal-title":"J Orthop Surg Res."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1007\/s12178-014-9216-0","article-title":"Periprosthetic fractures around the knee: current concepts and advances in management","volume":"7","author":"Whitehouse","year":"2014","journal-title":"Curr Rev Musculoskelet Med."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"189","DOI":"10.11138\/ccmbm\/2017.14.1.189","article-title":"Periprosthetic fractures: epidemiology and current treatment","volume":"14","author":"Capone","year":"2017","journal-title":"Clin Cases Min Bone Metab."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/BCO.0b013e3181bd6174","article-title":"Current management of distal femoral fractures","volume":"21","author":"Jahangir","year":"2010","journal-title":"Curr Orthop Pract."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1080\/17453670710014716","article-title":"Treatment of acute distal femur fractures above a total knee arthroplasty: systematic review of 415 cases (1981\u20132006)","volume":"79","author":"Herrera","year":"2008","journal-title":"Acta Orthop."},{"issue":"suppl 3","key":"R9-20230828","doi-asserted-by":"crossref","first-page":"SC32","DOI":"10.1016\/S0020-1383(01)00182-6","article-title":"Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results","volume":"32","author":"Kregor","year":"2001","journal-title":"Injury."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1302\/0301-620X.92B3.22996","article-title":"Are extreme distal periprosthetic supracondylar fractures of the femur too distal to fix using a lateral locked plate?","volume":"92","author":"Streubel","year":"2010","journal-title":"J Bone Joint Surg Br."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":"Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation","volume":"24","author":"Lujan","year":"2010","journal-title":"J Orthop Trauma."},{"issue":"suppl 1","key":"R12-20230828","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1097\/BOT.0b013e3182070127","article-title":"Locking plates for distal femur fractures: is there a problem with fracture healing?","volume":"25","author":"Henderson","year":"2011","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1016\/j.arth.2011.08.007","article-title":"High complication rate in locking plate fixation of lower periprosthetic distal femur fractures in patients with total knee arthroplasties","volume":"27","author":"Ebraheim","year":"2012","journal-title":"J Arthroplasty."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.injury.2013.10.042","article-title":"Predictive factors of distal femoral fracture nonunion after lateral locked plating: a retrospective multicenter case-control study of 283 fractures","volume":"45","author":"Rodriguez","year":"2014","journal-title":"Injury."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/BOT.0000000000000593","article-title":"Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures","volume":"30","author":"Rodriguez","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"e843","DOI":"10.3928\/01477447-20120525-22","article-title":"Open distal femur fractures treated with lateral locked implants: union, secondary bone grafting, and predictive parameters","volume":"35","author":"Barei","year":"2012","journal-title":"Orthopedics."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/S0020-1383(03)00262-6","article-title":"Reliability of radiographs in defining union of internally fixed fractures","volume":"35","author":"Davis","year":"2004","journal-title":"Injury."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/00003086-198510000-00033","article-title":"Accuracy of radiologic assessment of tibial shaft fracture union in humans","volume":"199","author":"Hammer","year":"1985","journal-title":"Clin Orthop Relat Res."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1302\/0301-620X.84B1.0840015","article-title":"Interobserver and intraobserver variation in the assessment of the healing of tibial fractures after intramedullary fixation","volume":"84","author":"Whelan","year":"2002","journal-title":"J Bone Joint Surg."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1177\/145749690609500207","article-title":"RSA applications in monitoring of fracture healing in clinical trials","volume":"95","author":"Madanat","year":"2006","journal-title":"Scand J Surg."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/01.blo.0000224001.95141.fe","article-title":"The history and future of radiostereometric analysis","volume":"448","author":"K\u00e4rrholm","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1080\/17453670510041574","article-title":"Guidelines for standardization of radiostereometry (RSA) of implants","volume":"76","author":"Valstar","year":"2005","journal-title":"Acta Orthop."},{"issue":"suppl 2","key":"R23-20230828","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1016\/j.injury.2014.04.006","article-title":"Biomechanical methods for the assessment of fracture repair","volume":"45","author":"Augat","year":"2014","journal-title":"Injury."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1302\/0301-620X.97B3.35077","article-title":"The stability of fixation of proximal femoral fractures: a radiostereometric analysis","volume":"97-B","author":"Van Embden","year":"2015","journal-title":"Bone Joint J."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1002\/jor.24150","article-title":"Radiostereometric analysis of the initial stability of internally fixed femoral neck fractures under differential loading","volume":"37","author":"Finnil\u00e4","year":"2019","journal-title":"J Orthop Res."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"e153","DOI":"10.1097\/BOT.0b013e3182383bcc","article-title":"Radiostereometric analysis in measurements of migration and inducible micromotion in intra-articular distal radius fractures treated with a volar plate","volume":"26","author":"Madanat","year":"2012","journal-title":"J Orthop Trauma."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"487","DOI":"10.3109\/17453674.2010.487930","article-title":"The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures","volume":"81","author":"Solomon","year":"2010","journal-title":"Acta Orthop."},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1302\/0301-620X.93B6.26122","article-title":"Weight-bearing-induced displacement and migration over time of fracture fragments following split depression fractures of the lateral tibial plateau","volume":"93","author":"Solomon","year":"2011","journal-title":"J Bone Joint Surg Br."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1007\/s11999-009-0708-y","article-title":"Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study","volume":"467","author":"Chehade","year":"2009","journal-title":"Clin Orthop Relat Res."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/01.blo.0000224008.19798.91","article-title":"Assessment of fragment micromotion in distal femur fracture fixation with RSA","volume":"448","author":"Duffy","year":"2006","journal-title":"Clin Orthop Relat Res."},{"issue":"suppl 1","key":"R31-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and dislocation classification compendium-2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"453","DOI":"10.2106\/00004623-197658040-00004","article-title":"Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones","volume":"58","author":"Gustilo","year":"1976","journal-title":"J Bone Joint Surg."},{"key":"R33-20230828","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/j.arth.2015.12.023","article-title":"Five-year experience of vitamin E-diffused highly cross-linked polyethylene wear in total hip arthroplasty assessed by radiostereometric analysis","volume":"31","author":"Nebergall","year":"2016","journal-title":"J Arthroplasty."},{"key":"R34-20230828","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1016\/S0736-0266(01)00171-1","article-title":"Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model","volume":"20","author":"Bragdon","year":"2002","journal-title":"J Orthop Res."},{"issue":"6 suppl 2","key":"R35-20230828","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.arth.2007.03.009","article-title":"Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads","volume":"22","author":"Bragdon","year":"2007","journal-title":"J Arthroplasty."},{"key":"R36-20230828","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/j.knee.2008.05.010","article-title":"Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures","volume":"15","author":"Chen","year":"2008","journal-title":"Knee."},{"key":"R37-20230828","doi-asserted-by":"crossref","first-page":"708574","DOI":"10.1155\/2014\/708574","article-title":"Current options for determining fracture union","volume":"2014","author":"Morshed","year":"2014","journal-title":"Adv Med."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001684","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:55:23Z","timestamp":1693205723000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001684"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":37,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001684","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]}}}