{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T05:18:32Z","timestamp":1776403112541,"version":"3.51.2"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To identify whether residents are at greater risk of radiation exposure from intraoperative fluoroscopy while earlier in their training and during more complex procedures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We analyzed 852 extracapsular proximal femur fracture fixation cases. We compared fluoroscopy times by various levels of resident training, fracture type, and implant used. Attending-only cases were used as a control group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Fluoroscopy times during subtrochanteric fracture fixation (176.1 \u00b1 11.27 seconds) were longer than intertrochanteric (111.4 \u00b1 2.44 seconds) and basicervical fractures (91.49 \u00b1 5.77 seconds). Long nail (150.2 \u00b1 3.75 seconds) times were longer than short (92.3 \u00b1 3.15 seconds) and intermediate (76.45 \u00b1 3.01 seconds) nails. Significantly, more fluoroscopy was used in junior (115.9 \u00b1 4.24 seconds), senior (123.0 \u00b1 6.08 seconds), junior combo (130.6 \u00b1 7.74 seconds), and senior combo cases (131.8 \u00b1 6.11 seconds) compared with the control (94.91 \u00b1 3.91).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Orthopaedic surgery residents and attendings must remain aware of radiation exposure secondary to intraoperative fluoroscopy. Appropriate personal protective equipment should be worn, and more experienced surgeons should take a more active role in the complex cases to decrease exposure risk.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001686","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T19:23:30Z","timestamp":1572895410000},"page":"e170-e175","source":"Crossref","is-referenced-by-count":7,"title":["Impact of Resident Training Level on Radiation Exposure During Fixation of Proximal Femur Fractures"],"prefix":"10.1097","volume":"34","author":[{"given":"Eric J.","family":"Buxbaum","sequence":"first","affiliation":[{"name":"Advanced Orthopedics and Sports Medicine Institute, Freehold, NJ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danielle Y.","family":"Ponzio","sequence":"additional","affiliation":[{"name":"The Rothman Institute, Egg Harbor Township, NJ; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sean","family":"Griffiths","sequence":"additional","affiliation":[{"name":"Inspira Health Network, Vineland, NJ."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eddie S.","family":"Wu","sequence":"additional","affiliation":[{"name":"Inspira Health Network, Vineland, NJ."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andres F.","family":"Duque","sequence":"additional","affiliation":[{"name":"The Rothman Institute, Egg Harbor Township, NJ; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zachary D.","family":"Post","sequence":"additional","affiliation":[{"name":"The Rothman Institute, Egg Harbor Township, NJ; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio R.","family":"Orozco","sequence":"additional","affiliation":[{"name":"The Rothman Institute, Egg Harbor Township, NJ; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alvin C.","family":"Ong","sequence":"additional","affiliation":[{"name":"The Rothman Institute, Egg Harbor Township, NJ; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"1324","DOI":"10.2106\/JBJS.16.01557","article-title":"Tracking cumulative radiation exposure in orthopaedic surgeons and residents: what dose are we getting?","volume":"99","author":"Gausden","year":"2017","journal-title":"J Bone Joint Surg. Am."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"326","DOI":"10.2106\/00004623-199303000-00003","article-title":"Exposure of the orthopaedic surgeon to radiation","volume":"75","author":"Sanders","year":"1993","journal-title":"J Bone Joint Surg Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"69","DOI":"10.5435\/00124635-200501000-00009","article-title":"Occupational radiation exposure to the surgeon","volume":"13","author":"Singer","year":"2005","journal-title":"J Am Acad Orthop Surg."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"268","DOI":"10.5435\/JAAOS-D-16-00342","article-title":"Radiation exposure and health risks for orthopaedic surgeons","volume":"26","author":"Hayda","year":"2018","journal-title":"J Am Acad Orthop Surg."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1848","DOI":"10.1093\/jnci\/88.24.1848","article-title":"Risk of basal cell and squamous cell skin cancers after ionizing radiation therapy. For the Skin Cancer Prevention Study Group","volume":"88","author":"Karagas","year":"1996","journal-title":"J Natl Cancer Inst."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1007\/s00411-013-0477-6","article-title":"Occupational exposure to low doses of ionizing radiation and cataract development: a systematic literature review and perspectives on future studies","volume":"52","author":"Hammer","year":"2013","journal-title":"Radiat Environ Biophys."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"237","DOI":"10.5271\/sjweh.3152","article-title":"Lens opacities among physicians occupationally exposed to ionizing radiation\u2014a pilot study in Finland","volume":"37","author":"Mrena","year":"2011","journal-title":"Scand J Work Environ Health."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"S98","DOI":"10.2307\/3578894","article-title":"Cancer incidence in atomic bomb survivors. Part IV: comparison of cancer incidence and mortality","volume":"137","author":"Ron","year":"1994","journal-title":"Radiat Res."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/00003086-200006000-00015","article-title":"The effects, risks, and guidelines for radiation use in orthopaedic surgery","volume":"375","author":"Herscovici","year":"2000","journal-title":"Clin Orthop Relat Res."},{"key":"R10-20230828","first-page":"1","article-title":"The 2007 recommendations of the international commission on radiological protection: ICRP publication 103","volume":"37","year":"2007","journal-title":"Ann ICRP."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/S0020-1383(98)00088-6","article-title":"Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing","volume":"29","author":"M\u00fcller","year":"1998","journal-title":"Injury."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/S0020-1383(02)00042-6","article-title":"Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb","volume":"33","author":"Madan","year":"2002","journal-title":"Injury."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"761","DOI":"10.2106\/00004623-198769050-00019","article-title":"Radiation exposure to the surgeon during closed interlocking intramedullary nailing","volume":"69","author":"Levin","year":"1987","journal-title":"J Bone Joint Surg Am."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/BPO.0000000000000422","article-title":"Measurement of radiation exposure when using the mini C-arm to reduce pediatric upper extremity fractures","volume":"36","author":"Sumko","year":"2016","journal-title":"J Pediatr Orthop."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/j.otsr.2011.03.024","article-title":"Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery?","volume":"97","author":"Roux","year":"2011","journal-title":"Orthop Traumatol Surg Res."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"e1165","DOI":"10.3928\/01477447-20130821-19","article-title":"Intraoperative radiation use by trainees during ankle fracture fixation","volume":"36","author":"Kheiran","year":"2013","journal-title":"Orthopedics."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/00005131-199708000-00002","article-title":"Radiation exposure to the orthopaedic surgical team during fluoroscopy: \u201chow far away is far enough?\u201d","volume":"11","author":"Mehlman","year":"1997","journal-title":"J Orthop Trauma."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s11845-014-1121-4","article-title":"Radiation safety knowledge and practices among Irish orthopaedic trainees","volume":"184","author":"Nugent","year":"2015","journal-title":"Ir J Med Sci."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"e16","DOI":"10.2106\/JBJS.17.00604","article-title":"What leads to lead: results of a nationwide survey exploring attitudes and practices of orthopaedic surgery residents regarding radiation safety","volume":"100","author":"Bowman","year":"2018","journal-title":"J Bone Joint Surg Am."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1007\/s11999-015-4631-0","article-title":"A radiation safety training program results in reduced radiation exposure for orthopaedic residents using the mini C-arm","volume":"474","author":"Gendelberg","year":"2016","journal-title":"Clin Orthop Relat Res."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1097\/BOT.0000000000000036","article-title":"Short versus long cephalomedullary nails for the treatment of intertrochanteric hip fractures in patients older than 65 years","volume":"28","author":"Kleweno","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"83","DOI":"10.3928\/01477447-20161116-01","article-title":"Short versus long cephalomedullary nails for pertrochanteric hip fracture","volume":"40","author":"Frisch","year":"2017","journal-title":"Orthopedics."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1097\/BOT.0000000000000420","article-title":"Short versus long intramedullary nails in the treatment of pertrochanteric hip fractures: incidence of ipsilateral fractures and costs associated with each implant","volume":"30","author":"Lindvall","year":"2016","journal-title":"J Orthop Trauma."},{"issue":"suppl 4","key":"R25-20230828","doi-asserted-by":"crossref","first-page":"S10","DOI":"10.1097\/BOT.0000000000000286","article-title":"Nailing intertrochanteric hip fractures: short versus long; locked versus nonlocked","volume":"29","author":"Kanakaris","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"e50","DOI":"10.5435\/JAAOS-D-15-00325","article-title":"Nail length in the management of intertrochanteric fracture of the femur","volume":"24","author":"Horwitz","year":"2016","journal-title":"J Am Acad Orthop Surg."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/BOT.0b013e31827cd5bd","article-title":"Is distal locking necessary? A biomechanical investigation of intramedullary nailing constructs for intertrochanteric fractures","volume":"27","author":"Gallagher","year":"2013","journal-title":"J Orthop Trauma"},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1097\/BOT.0000000000000165","article-title":"A biomechanical comparison of locked and unlocked long cephalomedullary nails in a stable intertrochanteric fracture model","volume":"28","author":"Kane","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1097\/BOT.0000000000000442","article-title":"Reduction of radiation exposure from C-arm fluoroscopy during orthopaedic trauma operations with introduction of real-time dosimetry","volume":"30","author":"Baumgartner","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R30-20230828","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1302\/0301-620X.62B2.7364839","article-title":"Irradiation of the surgeon during pinning of femoral fractures","volume":"62-B","author":"Giachino","year":"1980","journal-title":"J Bone Joint Surg Br"},{"key":"R31-20230828","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/00003086-198911000-00041","article-title":"Radiation exposure from fluoroscopy during orthopedic surgical procedures","volume":"248","author":"Riley","year":"1989","journal-title":"Clin Orthop Relat Res."},{"key":"R32-20230828","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/00003086-198401000-00020","article-title":"Radiation exposure to an orthopedic surgeon","volume":"182","author":"Barry","year":"1984","journal-title":"Clin Orthop Relat Res."},{"key":"R33-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2106\/00004623-198365010-00001","article-title":"Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures","volume":"65","author":"Miller","year":"1983","journal-title":"J Bone Joint Surg Am."},{"key":"R34-20230828","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.2106\/JBJS.L.00893","article-title":"Leaded eyeglasses substantially reduce radiation exposure of the surgeon's eyes during acquisition of typical fluoroscopic views of the hip and pelvis","volume":"95","author":"Burns","year":"2013","journal-title":"J Bone Joint Surg Am."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001686","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:16:30Z","timestamp":1693206990000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001686"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001686","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,5]]}}}