{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T01:53:03Z","timestamp":1781315583396,"version":"3.54.1"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,4]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To determine reoperation rates after treatment of a proximal humerus fracture with cage fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective case series.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Eleven U.S. hospitals.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients:<\/jats:title>\n            <jats:p>Fifty-two patients undergoing surgical treatment of proximal humerus fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Open reduction and internal fixation of a proximal humerus fracture with a proximal humerus cage.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Reoperation rate at 1 year.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>At a minimum follow-up of 1 year, reoperations occurred in 4\/52 patients (7.7%). Avascular necrosis (2\/41) occurred in 4.9% of patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Standard locked plating remains an imperfect solution for proximal humerus fractures. Proximal humerus cage fixation had low rates of revision surgery at 1 year. Proximal humerus cage fixation may offer reduced rates of complication and reoperation when compared with conventional locked plating for the management of proximal humerus fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001712","type":"journal-article","created":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T19:54:03Z","timestamp":1575662043000},"page":"193-198","source":"Crossref","is-referenced-by-count":11,"title":["Intramedullary Cage Fixation for Proximal Humerus Fractures Has Low Reoperation Rates at 1 Year: Results of a Multicenter Study"],"prefix":"10.1097","volume":"34","author":[{"given":"Lawrence Henry","family":"Goodnough","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospitals and Clinics, Stanford, CA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean T.","family":"Campbell","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospitals and Clinics, Stanford, CA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas C.","family":"Githens","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospitals and Clinics, Redwood City, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malcolm R.","family":"DeBaun","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospitals and Clinics, Stanford, CA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julius A.","family":"Bishop","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospitals and Clinics, Redwood City, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Gardner","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospitals and Clinics, Redwood City, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1097\/01.TA.0000170400.68994.AB","article-title":"Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation","volume":"58","author":"Hessmann","year":"2005","journal-title":"J Trauma."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1097\/TA.0b013e31822c1b5b","article-title":"The PHILOS plate for proximal humeral fractures\u2014risk factors for complications at one year","volume":"72","author":"Spross","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","article-title":"The importance of medial support in locked plating of proximal humerus fractures","volume":"21","author":"Gardner","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"e188","DOI":"10.1097\/BOT.0b013e31823db922","article-title":"The position and number of screws influence screw perforation of the humeral head in modern locking plates: a cadaver study","volume":"26","author":"Erhardt","year":"2012","journal-title":"J Orthop Trauma."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","article-title":"A systematic review of locking plate fixation of proximal humerus fractures","volume":"42","author":"Sproul","year":"2011","journal-title":"Injury."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.2106\/JBJS.H.00006","article-title":"Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study","volume":"91","author":"S\u00fcdkamp","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","article-title":"Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis","volume":"23","author":"Brunner","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R8-20230828","first-page":"1314","article-title":"Internal fixation of unstable proximal humerus fractures with an anatomically preshaped interlocking plate: a clinical and radiologic evaluation","volume":"63","author":"Hirschmann","year":"2007","journal-title":"J Trauma."},{"key":"R9-20230828","first-page":"460","article-title":"Second-generation concepts for locked plating of proximal humerus fractures","volume":"36","author":"Gardner","year":"2007","journal-title":"Am J Orthop."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/BOT.0b013e31815b3922","article-title":"Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant","volume":"22","author":"Gardner","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/BOT.0b013e3181589f8c","article-title":"The anterolateral acromial approach for fractures of the proximal humerus","volume":"22","author":"Gardner","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.15226\/2374-6904\/3\/2\/00149","article-title":"Techniques for using a novel intramedullary ccage technology for fixation of proximal humeral fractures","volume":"3","author":"Palmer","year":"2016","journal-title":"J Exerc Sports Orthop"},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"S11","DOI":"10.1097\/BOT.0000000000001062","article-title":"Humerus","volume":"32","year":"2018","journal-title":"J Orthop Trauma."},{"issue":"suppl 1","key":"R14-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and dislocation classification compendium-2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1302\/0301-620X.89B9.18528","article-title":"Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system","volume":"89","author":"Moonot","year":"2007","journal-title":"J Bone Joint Surg Br."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","article-title":"Analysis of efficacy and failure in proximal humerus fractures treated with locking plates","volume":"21","author":"Agudelo","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/01.blo.0000194678.87258.6e","article-title":"Fixation of proximal humerus fractures using the PHILOS plate: early experience","volume":"442","author":"Koukakis","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1016\/j.jse.2012.06.008","article-title":"Locking plate fixation of fractures of the proximal humerus: analysis of complications, revision strategies and outcome","volume":"22","author":"Jost","year":"2013","journal-title":"J Shoulder Elbow Surg."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"233","DOI":"10.2106\/JBJS.F.01351","article-title":"Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]","volume":"90","author":"Owsley","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1097\/BOT.0b013e31819344bf","article-title":"Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome","volume":"23","author":"Solberg","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1302\/0301-620X.86B6.14577","article-title":"Internal fixation of complex fractures of the proximal humerus","volume":"86","author":"Gerber","year":"2004","journal-title":"J Bone Joint Surg Br."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1097\/01.blo.0000137554.91189.a9","article-title":"A new locking plate for unstable fractures of the proximal humerus","author":"Fankhauser","year":"2005","journal-title":"Clin Orthop Relat Res."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"2325967116656829","DOI":"10.1177\/2325967116656829","article-title":"Fibular strut graft augmentation for open reduction and internal fixation of proximal humerus fractures","volume":"4","author":"Saltzman","year":"2016","journal-title":"Orthop J Sports Med."},{"key":"R24-20230828","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1097\/BOT.0000000000000012","article-title":"The impact of preoperative coronal plane deformity on proximal humerus fixation with endosteal augmentation","volume":"28","author":"Little","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"e822","DOI":"10.3928\/01477447-20140825-60","article-title":"Early outcomes of proximal humerus fracture fixation with locking plate and intramedullary fibular strut graft","volume":"37","author":"Tan","year":"2014","journal-title":"Orthopedics."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1016\/j.injury.2012.08.004","article-title":"Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus","volume":"43","author":"Matassi","year":"2012","journal-title":"Injury."},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"3300","DOI":"10.1007\/s11999-011-1949-0","article-title":"Endosteal strut augment reduces complications associated with proximal humeral locking plates","volume":"469","author":"Neviaser","year":"2011","journal-title":"Clin Orthop Relat Res."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001712","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:30:29Z","timestamp":1693207829000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001712"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001712","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,4]]}}}