{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T13:36:41Z","timestamp":1776087401252,"version":"3.50.1"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To assess the long-term functional results of both simple and comminuted olecranon fractures treated with tension band wiring (TBW).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients &amp; Intervention:<\/jats:title>\n            <jats:p>Between 2004 and 2014, 178 fractures in 178 patients &gt;16 years of age were treated with TBW for a unilateral olecranon fracture.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Subjective functionality was tested with the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and the Mayo Elbow Performance Index (MEPI).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Fifty percent of our cohort were lost to follow-up leaving 89 for review. A total of 51.7% had a comminuted fracture. Mean follow-up time was 7.1 years. Reoperation rate for implant removal was 84%. The total median DASH score was 0.83. Eighty-five patients (95.5%) were rated excellent using the MEPI score. No significant difference in either score was found between the simple (SF) and the comminuted (CF) group. Median range of motion was flexion\/extension: 145\/\u22122 degrees, supination\/pronation: 90\/90 degrees. No clinically relevant difference in range of motion was found between the 2 groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>We found no relevant differences in either subjective or objective functionality between patients with simple or comminuted olecranon fractures after fixation with TBW. Therefore, TBW seems to be an adequate and justifiable treatment modality for both simple and comminuted olecranon fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001728","type":"journal-article","created":{"date-parts":[[2020,6,17]],"date-time":"2020-06-17T10:32:41Z","timestamp":1592389961000},"page":"e239-e244","source":"Crossref","is-referenced-by-count":7,"title":["Tension Band Wiring Provides Excellent Patient-Reported Long-Term Results for Both Comminuted and Simple Displaced Olecranon Fractures"],"prefix":"10.1097","volume":"34","author":[{"given":"Afra L. E.","family":"Terstappen","sequence":"first","affiliation":[{"name":"Trauma Surgery, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pieter","family":"Joosse","sequence":"additional","affiliation":[{"name":"Trauma Surgery, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cornelis F.","family":"van Dijke","sequence":"additional","affiliation":[{"name":"Radiology, Northwest Clinics, Alkmaar, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Boj","family":"Mirck","sequence":"additional","affiliation":[{"name":"Trauma Surgery, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan G. H.","family":"van den Brand","sequence":"additional","affiliation":[{"name":"Trauma Surgery, and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","first-page":"6","article-title":"Osteosynthesis in olecranon fractures","volume":"56","author":"Weber","year":"1963","journal-title":"Z Unfallmed Berufskr."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"2416","DOI":"10.2106\/JBJS.H.01419","article-title":"Clinical evaluation of locking compression plate fixation for comminuted olecranon fractures","volume":"91","author":"Buijze","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.injury.2016.04.015","article-title":"Outcomes after plating of olecranon fractures: a multicenter evaluation","volume":"47","author":"De Giacomo","year":"2016","journal-title":"Injury."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.otsr.2014.09.025","article-title":"Critical analysis of olecranon fracture management by pre-contoured locking plates","volume":"101","author":"Niglis","year":"2015","journal-title":"Orthop Traumatol Surg Res."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1007\/s00590-015-1724-0","article-title":"Outcome after olecranon fracture repair: does construct type matter?","volume":"26","author":"DelSole","year":"2016","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.2106\/JBJS.16.00773","article-title":"Plate versus tension-band wire fixation for olecranon fractures","volume":"99","author":"Duckworth","year":"2017","journal-title":"J Bone Joint Surg."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1007\/s00402-014-2021-9","article-title":"Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques","volume":"134","author":"Tarallo","year":"2014","journal-title":"Arch Orthop Trauma Surg."},{"key":"R8-20230828","first-page":"CD010144","article-title":"Surgical interventions for treating fractures of the olecranon in adults (Review)","volume":"11","author":"Matar","year":"2014","journal-title":"Cochrane Libr."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1186\/s13018-016-0465-z","article-title":"Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis","volume":"11","author":"Ren","year":"2016","journal-title":"J Orthop Surg Res."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and Dislocation Classification Compendium - 2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.jse.2005.08.002","article-title":"Tension-band wiring for olecranon fractures: analysis of risk factors for failure","volume":"15","author":"Villanueva","year":"2006","journal-title":"J Shoulder Elbow Surg."},{"key":"R14-20230828","first-page":"106","article-title":"Comparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures","volume":"80","author":"Schliemann","year":"2014","journal-title":"Acta Orthop Belg."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"208","DOI":"10.2106\/00004623-200202000-00007","article-title":"Hunsaker normative values from the general population","volume":"84-A","author":"Hunsaker","year":"2002","journal-title":"J Bone Joint Surg."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s12306-016-0449-5","article-title":"The treatment of olecranon fractures in adults","volume":"101","author":"Powell","year":"2017","journal-title":"Musculoskelet Surg."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"831","DOI":"10.2106\/00004623-200305000-00010","article-title":"Cyclic loading of olecranon fracture fixation constructs","volume":"85-A","author":"Hutchinson","year":"2003","journal-title":"J Bone Joint Surg Am."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1302\/0301-620X.93B2.24613","article-title":"Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon","volume":"93-B","author":"Wilson","year":"2011","journal-title":"J Bone Joint Surg Br."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1007\/s007760070036","article-title":"Complications and re-operation rate after tension-band wiring of olecranon fractures","volume":"5","author":"Romero","year":"2000","journal-title":"J Orthop Sci."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001728","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:05:54Z","timestamp":1693206354000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001728"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":17,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001728","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,7]]}}}