{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T06:20:14Z","timestamp":1788070814341,"version":"build-2784847793"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>One of the main shortcomings of current proximal humeral plate designs is their inability to reliably secure the greater tuberosity (GT) or lesser tuberosity, leading to fixation failure, nonunion, and rotator cuff dysfunction. Traditional proximal humeral locking plates (PHLPs) rely on isolated screw fixation or suture repair to maintain reduction of the greater and\/or lesser tuberosities. This study evaluates a tuberosity-based plate (TBP) specifically designed to improve tuberosity fixation, which may decrease tuberosity displacement and related clinical sequelae.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Five cadaveric specimens (10 shoulders) were randomized to receive either standard PHLP or TBP fixation. The specimens were skeletonized except for the rotator cuff insertion on the GT. A reproducible 3-part osteotomy was performed for each cadaver, creating head, shaft, and GT segments. Anatomic reduction and plate fixation were performed according to the surgical technique guide for each plate system, with an equal number of screws placed in each plate both proximally and distally. GT fixation was enhanced with standardized suture augmentation through the rotator cuff in every specimen in both groups. In each trial, fracture displacement, load to failure, number of cycles endured, and mechanism of failure were noted.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The mean load to tuberosity fixation failure for the PHLP and TBP groups was 220 and 502 N (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.005), respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The TBP had a significantly higher load to failure and significantly lower mean fracture displacement compared with the PHLP.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001744","type":"journal-article","created":{"date-parts":[[2020,1,24]],"date-time":"2020-01-24T19:12:31Z","timestamp":1579893151000},"page":"e233-e238","source":"Crossref","is-referenced-by-count":9,"title":["A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures"],"prefix":"10.1097","volume":"34","author":[{"given":"Robert","family":"Walker","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Arizona College of Medicine\u2014Phoenix, Phoenix, AZ; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulo","family":"Castaneda","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Arizona College of Medicine\u2014Phoenix, Phoenix, AZ; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jill G.","family":"Putnam","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Arizona College of Medicine\u2014Phoenix, Phoenix, AZ; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emil H.","family":"Schemitsch","sequence":"additional","affiliation":[{"name":"Department of Surgery, Western University, London, ON, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael D.","family":"McKee","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Arizona College of Medicine\u2014Phoenix, Phoenix, AZ; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/BOT.0000000000000229","article-title":"Surgical management of complex proximal humerus fractures-a systematic review of 92 studies including 4500 patients","volume":"29","author":"Gupta","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1016\/j.jse.2013.12.034","article-title":"The incidence of proximal humeral fractures in New York State from 1990 through 2010 with an emphasis on operative management in patients aged 65 years or older","volume":"23","author":"Khatib","year":"2014","journal-title":"J Shoulder Elbow Surg."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"121","DOI":"10.2106\/JBJS.I.01505","article-title":"Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly","volume":"93","author":"Bell","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1007\/s00104-006-1241-0","article-title":"Management of complications after angularly stable locking proximal humerus plate fixation [in German]","volume":"78","author":"Voigt","year":"2007","journal-title":"Chir Z Alle Geb Oper Medizen."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"233","DOI":"10.2106\/JBJS.F.01351","article-title":"Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]","volume":"90","author":"Owsley","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1055\/s-2006-958639","article-title":"Proximal humeral fractures with angle-stable plate osteosynthesis\u2014is everything better now? [in German]","volume":"132","author":"Frangen","year":"2007","journal-title":"Zentralbl Chir."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.injury.2008.05.030","article-title":"Humeral head necrosis rate at mid-term follow-up after open reduction and angular stable plate fixation for proximal humeral fractures","volume":"40","author":"Greiner","year":"2009","journal-title":"Injury."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/s10195-017-0457-8","article-title":"Failure and revision rates of proximal humeral fracture treatment with the use of a standardized treatment algorithm at a level-1 trauma center","volume":"18","author":"Katthagen","year":"2017","journal-title":"J Orthop Traumatol."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1186\/1754-9493-7-34","article-title":"Complication rates and outcomes stratified by treatment modalities in proximal humeral fractures: a systematic literature review from 1970\u20132009","volume":"7","author":"Tepass","year":"2013","journal-title":"Patient Saf Surg."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"e262","DOI":"10.1097\/BOT.0000000000000575","article-title":"Biomechanical contribution of tension-reducing rotator cuff sutures in 3-part proximal humerus fractures","volume":"30","author":"Arvesen","year":"2016","journal-title":"J Orthop Trauma."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1016\/j.clinbiomech.2006.06.005","article-title":"Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model","volume":"21","author":"Walsh","year":"2006","journal-title":"Clin Biomech Bristol Avon."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"5904028","DOI":"10.1155\/2018\/5904028","article-title":"Minimally invasive plate osteosynthesis for proximal humerus fractures: a retrospective study describing principles and advantages of the technique","volume":"2018","author":"Alberio","year":"2018","journal-title":"Adv Orthop."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.jse.2009.09.005","article-title":"Pitfalls and complications with locking plate for proximal humerus fracture","volume":"19","author":"Clavert","year":"2010","journal-title":"J Shoulder Elbow Surg."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1016\/j.jse.2014.09.032","article-title":"Effect of shoulder abduction on the fixation of humeral greater tuberosity fractures: a biomechanical study for three types of fixation constructs","volume":"24","author":"Lin","year":"2015","journal-title":"J Shoulder Elbow Surg."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1016\/j.jse.2016.02.012","article-title":"Reverse shoulder arthroplasty for proximal humeral fractures: outcomes comparing primary reverse arthroplasty for fracture versus reverse arthroplasty after failed osteosynthesis","volume":"25","author":"Shannon","year":"2016","journal-title":"J Shoulder Elbow Surg."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1302\/2046-3758.61.BJR-2016-0145.R1","article-title":"Ultimate fracture load of cadaver proximal humeri correlates more strongly with mean combined cortical thickness than with areal cortical index, DEXA density, or canal-to-calcar ratio","volume":"6","author":"Skedros","year":"2017","journal-title":"Bone Joint Res."},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.jse.2013.06.024","article-title":"Biomechanical testing of small versus large lesser tuberosity osteotomies: effect on gap formation and ultimate failure load","volume":"23","author":"Fishman","year":"2014","journal-title":"J Shoulder Elbow Surg."},{"key":"R18-20230828","first-page":"98","article-title":"Fixation of greater tuberosity fractures: a biomechanical comparison of three techniques","volume":"63","author":"Ishak","year":"2006","journal-title":"Bull Hosp Jt Dis."},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1002\/jor.1100130413","article-title":"Tensile properties of the supraspinatus tendon","volume":"13","author":"Itoi","year":"1995","journal-title":"J Orthop Res."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.jse.2004.01.034","article-title":"Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus","volume":"13","author":"Hertel","year":"2004","journal-title":"J Shoulder Elbow Surg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001744","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:05:48Z","timestamp":1693206348000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001744"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":20,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001744","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,7]]}}}