{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T23:46:54Z","timestamp":1770335214143,"version":"3.49.0"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Standard titanium nails (TN) or carbon fiber\u2013reinforced PEEK nails (CFN) were compared to evaluate impact of material on fracture union, healing time, knee\/ankle, and barometric pain.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Longitudinal cohort evaluated retrospectively comparing 2 periods using 2 implant types.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Single surgeon series at one Level II Trauma Center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients:<\/jats:title>\n            <jats:p>Standardized treatment protocol. Fifty-six tibial fracture patients suitable for intramedullary nailing over 5-year period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>First period\u2014TN; second period\u2014CFN.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome:<\/jats:title>\n            <jats:p>Measurements: standard demographic data: OTA\/AO fracture classification, fracture location, and nail type. Outcome parameters: cumulative healing at standard time intervals, infection\/nonunion, associated injuries, knee\/ankle, barometric pain, and implant removal. Statistical analysis comparing incident healing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Patient populations were not statistically different regarding demographics and fracture type\/location, although there was a trend toward greater fracture severity\/more associated injuries in CFN group. In 56 patients, 26 received CFN and 30 received TN. Healing rates were reported at each time interval. 8 weeks: TN\u20140%, CFN\u201419%; 12 weeks: TN\u201417%, CFN\u201469%; 16 weeks: TN\u201457%, CFN\u201492%; 20 weeks: TN\u201487%, CFN\u201496%; and 24 weeks: TN\u201497%, CFN\u201496% (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.0001 every interval except 24 weeks). Each group had one infected nonunion in an open fracture that healed with subsequent treatment. There was a trend toward less barometric pain with CFN that did not reach statistical significance (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.065). No statistical differences with knee\/ankle pain (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.109)\/removal of implant (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.269) potentially due to low power of pilot study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>In this pilot study evaluating CFR-PEEK intramedullary nail for tibial shaft fractures, there was a demonstrated accelerated healing times compared to titanium with a potential for less barometric pain.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001756","type":"journal-article","created":{"date-parts":[[2020,3,11]],"date-time":"2020-03-11T00:48:49Z","timestamp":1583887729000},"page":"429-433","source":"Crossref","is-referenced-by-count":15,"title":["Carbon Fiber\u2013Reinforced PEEK Versus Titanium Tibial Intramedullary Nailing: A Preliminary Analysis and Results"],"prefix":"10.1097","volume":"34","author":[{"given":"Bruce Harris","family":"Ziran","sequence":"first","affiliation":[{"name":"The Hughston Clinic, Atlanta, GA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erin Kathleen","family":"O'Pry","sequence":"additional","affiliation":[{"name":"OMS IV, Philadelphia College of Osteopathic Medicine, Atlanta, GA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert Mitchell","family":"Harris","sequence":"additional","affiliation":[{"name":"Jack Hughston Memorial Hospital, The Hughston Clinic, Columbus, GA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1097\/BOT.0000000000001132","article-title":"Segmental tibia fractures. An analysis of complication and healing rates","volume":"32","author":"Corey","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1007\/s00256-015-2158-9","article-title":"Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging","volume":"44","author":"Zimel","year":"2015","journal-title":"Skelet Radiol."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"825","DOI":"10.3928\/01477447-20141124-05","article-title":"Use of carbon fiber reinforced composite implants in orthopaedic surgery","volume":"37","author":"Hak","year":"2014","journal-title":"Orthopedics."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1016\/j.injury.2016.05.043","article-title":"Nature's wrath-The effect of weather on pain following orthopaedic trauma","volume":"47","author":"Shulman","year":"2016","journal-title":"Injury."},{"key":"R7-20230828","article-title":"External fixation of segmental tibial shaft fractures","author":"Milenkovic","year":"2018","journal-title":"Eur J Trauma Emerg Surg."},{"key":"R8-20230828","first-page":"91","article-title":"Study to prospectively evaluate reamed intramedullary nails in patients with tibial fractures (SPRINT): study rationale and design","volume":"23","author":"Bhandari","year":"2008","journal-title":"BMC Musculoskelet Disord."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"97","DOI":"10.5435\/00124635-200702000-00004","article-title":"Intramedullary nailing of the lower extremity: biomechanics and biology","volume":"15","author":"Bong","year":"2007","journal-title":"J Am Acad Orthop Surg."},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.clinbiomech.2011.08.009","article-title":"A novel intramedullary nail for micromotion stimulation of tibial fractures","volume":"27","author":"Dailey","year":"2012","journal-title":"Clin Biomech."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1097\/BOT.0000000000001223","article-title":"Early comparative outcomes of carbon fiber reinforced polymer plate in the fixation of distal femur fractures","volume":"32","author":"Mitchell","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1302\/0301-620X.75B2.8444937","article-title":"The effect of the entry hole for an intramedullary nail on the strength of the proximal femur","volume":"75","author":"Miller","year":"1993","journal-title":"J Bone Joint Surg Br."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1097\/00005131-199109000-00013","article-title":"Mechanical characterization of femoral interlocking intramedullary nailing systems","volume":"5","author":"Russell","year":"1991","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001756","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T07:31:11Z","timestamp":1693207871000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001756"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8]]},"references-count":11,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001756","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8]]}}}