{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T15:09:02Z","timestamp":1774278542268,"version":"3.50.1"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To determine if the addition of a dorsal ulnar pin plate provides improved stability characteristics in the management of intra-articular distal radius fractures with an associated dorsal ulnar fragment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>OTA\/AO type C3 fractures, with a dorsal ulnar fragment of one-third or one-half the width of the distal radius, were simulated in 9 matched pairs of fresh-frozen cadaveric arms randomized between fixed-angle volar plate only versus volar plate with addition of a dorsal ulnar pin plate. Prepared specimens were mounted in a custom load frame and loaded in extension with stepwise cyclic load increase. Dorsal plane interfragmentary displacements were compared between the 2 fixation constructs at 50-N and 100-N cyclic load.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The addition of the dorsal ulnar pin plate significantly reduced interfragmentary displacements for the dorsal ulnar fragment at the 50 N load application, resulting in mean interfragmentary displacements of \u22120.1 \u00b1 0.2 mm in comparison to \u22120.3 \u00b1 0.2 mm with the volar plate\u2013only construct. No other interfragmentary displacement comparisons were significant. No differences were found comparing the one-third and one-half size fragments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The addition of a dorsal ulnar pin plate improved stability characteristics with respect to the dorsal ulnar fragment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>The addition of the dorsal ulnar pin plate, although statistically significant, improved displacement by less than 0.3 mm on average and thus may not prove to be important in clinical scenarios.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000001776","type":"journal-article","created":{"date-parts":[[2020,4,6]],"date-time":"2020-04-06T14:51:06Z","timestamp":1586184666000},"page":"e298-e303","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Biomechanical Stability of Volar Plate Only Versus Addition of Dorsal Ulnar Pin Plate: A Dorsal Ulnar Fragment, C-3\u2013Type, Distal Radius, Cadaver Fracture Model"],"prefix":"10.1097","volume":"34","author":[{"given":"Nathan C.","family":"Patrick","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory S.","family":"Lewis","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evan P.","family":"Roush","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah S.","family":"Black","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stacy R.","family":"Henderson","sequence":"additional","affiliation":[{"name":"Division of Plastic Surgery, Department of Surgery, Penn State Milton S. Hershey Medical Center, Hershey, PA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth F.","family":"Taylor","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20260121","doi-asserted-by":"crossref","first-page":"691e697","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: a review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury."},{"key":"R3-20260121","doi-asserted-by":"crossref","first-page":"205e215","DOI":"10.1053\/jhsu.2002.32081","article-title":"Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report","volume":"27","author":"Orbay","year":"2002","journal-title":"J Hand Surg Am."},{"key":"R4-20260121","doi-asserted-by":"crossref","first-page":"1855e1861","DOI":"10.2106\/JBJS.G.01569","article-title":"Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence?","volume":"90","author":"Koval","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R5-20260121","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.jhsa.2006.10.007","article-title":"Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results","volume":"32","author":"Rikli","year":"2007","journal-title":"J Hand Surg Am."},{"key":"R6-20260121","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1053\/jhsu.2000.6915","article-title":"Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation","volume":"25","author":"Putnam","year":"2000","journal-title":"J Hand Surg Am."},{"key":"R7-20260121","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.jhsa.2005.12.017","article-title":"Biomechanical stability of a fixed-angle volar plate versus fragment-specific fixation system: cyclic testing in a C2-type distal radius cadaver fracture model","volume":"31","author":"Taylor","year":"2006","journal-title":"J Hand Surg Am."},{"key":"R8-20260121","doi-asserted-by":"crossref","first-page":"1907","DOI":"10.1016\/j.jhsa.2011.08.039","article-title":"A biomechanical comparison of volar locked plating of intra-articular distal radius fractures: use of 4 versus 7 screws for distal fixation","volume":"36","author":"Moss","year":"2011","journal-title":"J Hand Surg Am."},{"key":"R9-20260121","article-title":"Effect of metacarpal fixation configuration on strength and fracture gap displacements in a cadaveric model of externally fixed distal radius fractures","author":"Taylor","year":"2019","journal-title":"Hand (N Y)."},{"key":"R10-20260121","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0363-5023(88)90189-X","article-title":"Relative motion of selected carpal bones: a kinematic analysis of the normal wrist","volume":"13","author":"Ruby","year":"1988","journal-title":"J Hand Surg Am."},{"key":"R11-20260121","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1053\/jhsu.1999.0992","article-title":"Supplemental pinning improves the stability of external fixation in distal radius fractures during simulated finger and forearm motion","volume":"24","author":"Dunning","year":"1999","journal-title":"J Hand Surg Am."},{"key":"R12-20260121","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1002\/jor.1100070418","article-title":"Effects of a scaphoid waist osteotomy on carpal kinematics","volume":"7","author":"Smith","year":"1989","journal-title":"J Orthop Res."},{"key":"R13-20260121","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.jhsa.2008.01.024","article-title":"Prospective study of distal radius fractures treated with a volar locking plate system","volume":"33","author":"Osada","year":"2008","journal-title":"J Hand Surg Am."},{"key":"R14-20260121","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.jhsa.2003.09.015","article-title":"Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient","volume":"29","author":"Orbay","year":"2004","journal-title":"J Hand Surg Am."},{"key":"R15-20260121","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.jhsa.2016.05.015","article-title":"Distal radius fractures: approaches, indications, and techniques","volume":"41","author":"Alluri","year":"2016","journal-title":"J Hand Surg Am."},{"key":"R16-20260121","doi-asserted-by":"crossref","first-page":"2146","DOI":"10.2106\/JBJS.J.01597","article-title":"A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older","volume":"93","author":"Arora","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R17-20260121","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.jhsa.2004.11.014","article-title":"Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation","volume":"30","author":"Wright","year":"2005","journal-title":"J Hand Surg Am."},{"key":"R18-20260121","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1097\/PRS.0b013e3181891677","article-title":"A comparative study of fragment-specific versus volar plate fixation of distal radius fractures","volume":"122","author":"Sammer","year":"2008","journal-title":"Plast Reconstr Surg."},{"key":"R19-20260121","first-page":"CD003324","article-title":"Rehabilitation for distal radial fractures in adults","volume":"9","author":"Handoll","year":"2015","journal-title":"Cochrane Database Syst Rev."},{"key":"R20-20260121","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.2106\/JBJS.G.01368","article-title":"Wrist mobilization following volar plate fixation of fractures of the distal part of the radius","volume":"90","author":"Lozano-Calder\u00f3n","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R21-20260121","first-page":"102","article-title":"Early rehabilitation of distal radius fractures stabilized by volar locking plate: a prospective randomized pilot study","volume":"6","author":"Quadlbauer","year":"2017","journal-title":"J Wrist Surg Am."},{"key":"R22-20260121","doi-asserted-by":"crossref","first-page":"1837","DOI":"10.2106\/JBJS.H.01478","article-title":"Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial","volume":"91","author":"Rozental","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R23-20260121","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/j.jhsa.2011.04.004","article-title":"Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study","volume":"36","author":"Yu","year":"2011","journal-title":"J Hand Surg Am."},{"key":"R24-20260121","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.jhsa.2008.01.006","article-title":"Volar plating of AO C3 distal radius fractures: biomechanical evaluation of locking screw and locking smooth peg configurations","volume":"33","author":"Martineau","year":"2008","journal-title":"J Hand Surg Am."},{"key":"R25-20260121","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.jhsa.2006.02.015","article-title":"Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study","volume":"31","author":"Koh","year":"2006","journal-title":"J Hand Surg Am."},{"key":"R26-20260121","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1053\/jhsu.2003.50016","article-title":"Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study","volume":"28","author":"Osada","year":"2003","journal-title":"J Hand Surg Am."},{"key":"R27-20260121","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.jhsa.2011.12.013","article-title":"The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates","volume":"37","author":"Wall","year":"2012","journal-title":"J Hand Surg Am."},{"key":"R28-20260121","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1302\/0301-620X.82B1.0820079","article-title":"Anatomical reduction of intra-articular fractures of the distal radius. An arthroscopically-assisted approach","volume":"82","author":"Mehta","year":"2000","journal-title":"J Bone Joint Surg Br."},{"key":"R29-20260121","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1097\/BOT.0000000000001261","article-title":"Biomechanical evaluation of osteoporotic proximal periprosthetic fractures with proximal bicortical fixation and allograft struts","volume":"32","author":"O'Connell","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R30-20260121","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1097\/BOT.0000000000000879","article-title":"Comparison of 4 methods for dynamization of locking plates: differences in the amount and type of fracture motion","volume":"31","author":"Henschel","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R31-20260121","doi-asserted-by":"crossref","first-page":"e204","DOI":"10.1097\/BOT.0000000000001147","article-title":"Are variable-angle locking screws stable enough to prevent calcaneal articular surface collapse? A biomechanical study","volume":"32","author":"Jordan","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R32-20260121","doi-asserted-by":"crossref","first-page":"e262","DOI":"10.1097\/BOT.0000000000000575","article-title":"Biomechanical contribution of tension-reducing rotator cuff sutures in 3-part proximal humerus fractures","volume":"30","author":"Arvesen","year":"2016","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001776","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T14:01:41Z","timestamp":1769004101000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001776"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9]]},"references-count":31,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001776","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2020,9]]},"assertion":[{"value":"2020-03-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}