{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T00:55:33Z","timestamp":1788742533578,"version":"build-2803163510"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To evaluate the functional outcomes of patients with displaced patellar fractures treated with anterior plate constructs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective cohort and retrospective clinical and radiographic assessment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level I Trauma Center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Between 2014 and 2018, 18 patients who underwent operative intervention for an isolated, displaced patella fracture (OTA\/AO 34C1-3) with a minimum of 1-year follow-up agreed to participate in the study. The mean follow-up was 19.5 \u00b1 6.0 months.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Patients were treated with 2.4 or 2.7-mm plates and supplemental screws or cerclage wires.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Patients were evaluated with the Short Form-36 Survey and the Knee Injury and Osteoarthritis Outcome Scores and asked about symptomatic implants. The range of motion was assessed by goniometer.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The cohort had no wound complications, infections, nonunion, loss of reduction, or implant failure. Active knee flexion was 131 \u00b1 7 degrees. Five patients (28%) endorsed implant irritation. Only one patient (5.5%) underwent implant removal, which consisted of transverse screw removal alone. Twelve of the 14 patients (86%), who were previously employed, returned to work at 10 \u00b1 7 weeks. All Knee Injury and Osteoarthritis Outcome Scores subscale scores and the Short Form-36 Survey scores for physical functioning, limitations due to physical health, limitations due to mental health, and social functioning were significantly lower than reference population norms (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Anterior plating provides reliable fixation for displaced patellar fractures and results in a low incidence of implant irritation. However, patients who had anterior fixation for displaced patella fractures continue to exhibit functional deficits at 1-year postoperatively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001868","type":"journal-article","created":{"date-parts":[[2020,10,20]],"date-time":"2020-10-20T18:01:49Z","timestamp":1603216909000},"page":"e1-e6","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":15,"title":["Functional Outcomes of Patella Fractures Treated With Anterior Plate Osteosynthesis at One Year"],"prefix":"10.1097","volume":"35","author":[{"given":"Stephen J.","family":"Shymon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hayley","family":"Jansson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian A.","family":"Schneiderman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Nazareth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher Max","family":"Hoshino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel M.","family":"Zinar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stuart M.","family":"Gold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/ort.1972.43.suppl-143.01","article-title":"Fracture of the patella. A study of 422 patellar fractures","volume":"143","author":"Bostr\u00f6m","year":"1972","journal-title":"Acta Orthop Scand Suppl."},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1302\/0301-620X.67B3.3997951","article-title":"Results of surgical treatment of patellar fractures","volume":"67","author":"Levack","year":"1985","journal-title":"J Bone Joint Surg Br."},{"key":"R3-20250614","first-page":"97","article-title":"Fractures of the patella","volume":"43","author":"Carpenter","year":"1994","journal-title":"Instr Course Lect."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"653","DOI":"10.2106\/JBJS.K.01549","article-title":"Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires","volume":"95","author":"Hoshino","year":"2013","journal-title":"J Bone Joint Surg Am."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/BOT.0000000000000787","article-title":"Superior outcomes after operative fixation of patella fractures using a novel plating technique","volume":"31","author":"Lorich","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.injury.2009.07.007","article-title":"Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures","volume":"41","author":"Dargel","year":"2010","journal-title":"Injury."},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1097\/00005131-199711000-00005","article-title":"Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws","volume":"11","author":"Berg","year":"1997","journal-title":"J Orthop Trauma."},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"e961","DOI":"10.2106\/JBJS.L.00012","article-title":"Outcomes after operative fixation of complete articular patellar fractures: assessment of functional impairment","volume":"95","author":"Lazaro","year":"2013","journal-title":"J Bone Joint Surg Am."},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"215","DOI":"10.5792\/ksrr.2013.25.4.215","article-title":"Percutaneous cannulated screws with tension band wiring technique in patella fractures","volume":"25","author":"Cho","year":"2013","journal-title":"Knee Surg Relat Res."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1097\/00005131-199707000-00009","article-title":"Biomechanical evaluation of current patella fracture fixation techniques","volume":"11","author":"Carpenter","year":"1997","journal-title":"J Orthop Trauma."},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0020-1383(99)00190-4","article-title":"Fixation of patella fractures with braided polyester suture: a biomechanical study","volume":"31","author":"Patel","year":"2000","journal-title":"Injury."},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0020-1383(00)00170-4","article-title":"Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester\u2014a study of 37 cases","volume":"32","author":"Gosal","year":"2001","journal-title":"Injury."},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1097\/BOT.0b013e318228c1a1","article-title":"Functional outcomes after operatively treated patella fractures","volume":"26","author":"LeBrun","year":"2012","journal-title":"J Orthop Trauma."},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1097\/TA.0b013e31825168b6","article-title":"Meta-analysis of re-operation, nonunion, and infection after open reduction and internal fixation of patella fractures","volume":"73","author":"Dy","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1016\/j.injury.2012.04.020","article-title":"Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures","volume":"43","author":"Thelen","year":"2012","journal-title":"Injury."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.clinbiomech.2009.12.010","article-title":"Fixed-angle plate osteosynthesis of the patella\u2014an alternative to tension wiring?","volume":"25","author":"Wild","year":"2010","journal-title":"Clin Biomech."},{"key":"R17-20250614","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.injury.2004.09.020","article-title":"The basket plate in the osteosynthesis of comminuted fractures of distal pole of the patella","volume":"37","author":"Matej\u010di\u0107","year":"2006","journal-title":"Injury."},{"key":"R18-20250614","doi-asserted-by":"crossref","first-page":"e231","DOI":"10.1097\/BOT.0000000000000039","article-title":"Plating of patella fractures: techniques and outcomes","volume":"28","author":"Taylor","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R19-20250614","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1007\/s00402-015-2241-7","article-title":"Treatment of patella fracture by claw-like shape memory alloy","volume":"135","author":"Hao","year":"2015","journal-title":"Arch Orthop Trauma Surg."},{"key":"R20-20250614","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.injury.2018.03.030","article-title":"Fixed angle plate fixation of comminuted patellar fractures","volume":"49","author":"Moore","year":"2018","journal-title":"Injury."},{"key":"R21-20250614","first-page":"599","article-title":"Outcomes research in orthopaedics","volume":"43","author":"Keller","year":"1994","journal-title":"Instr Course Lect."},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"3130","DOI":"10.1097\/00007632-200012150-00008","article-title":"SF-36 health survey update","volume":"25","author":"Ware","year":"2000","journal-title":"Spine (Phila PA 1976)."},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1097\/00005650-199206000-00002","article-title":"The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection","volume":"30","author":"Ware","year":"1992","journal-title":"Med Care."},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1097\/00005373-199511000-00005","article-title":"Functional status following orthopedic trauma in young women","volume":"39","author":"McCarthy","year":"1995","journal-title":"J Trauma."},{"key":"R25-20250614","first-page":"527","article-title":"Using the SF-36 for characterizing outcome after multiple trauma involving head injury","volume":"52","author":"MacKenzie","year":"2002","journal-title":"J Trauma."},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/00005650-199401000-00004","article-title":"The MOS 36-item Short-Form Health Survey (SF-36): III. Tests of data quality, scaling assumptions, and reliability across diverse patient groups","volume":"32","author":"McHorney","year":"1994","journal-title":"Med Care."},{"key":"R27-20250614","doi-asserted-by":"crossref","first-page":"88","DOI":"10.2519\/jospt.1998.28.2.88","article-title":"Knee Injury and Osteoarthritis Outcome Score (KOOS)\u2014development of a self-administered outcome measure","volume":"28","author":"Roos","year":"1998","journal-title":"J Orthop Sport Phys Ther."},{"key":"R28-20250614","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1186\/1477-7525-1-64","article-title":"The Knee injury and Osteoarthritis Outcome Score (KOOS): from joint injury to osteoarthritis","volume":"1","author":"Roos","year":"2003","journal-title":"Heal Qual Life Outcomes."},{"key":"R30-20250614","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/1471-2474-7-38","article-title":"Knee complaints vary with age and gender in the adult population. Population-based reference data for the Knee injury and Osteoarthritis Outcome Score (KOOS)","volume":"7","author":"Paradowski","year":"2006","journal-title":"BMC Musculoskelet Disord."},{"key":"R31-20250614","doi-asserted-by":"crossref","first-page":"e504","DOI":"10.1097\/BOT.0000000000000415","article-title":"Multiplanar fixation for patella fractures using a low-profile mesh plate","volume":"29","author":"Lorich","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R32-20250614","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1016\/j.injury.2016.02.019","article-title":"Health related quality of life and return to work after minor extremity injuries: a longitudinal study comparing upper versus lower extremity injuries","volume":"47","author":"Sluys","year":"2016","journal-title":"Injury."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001868","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T19:04:37Z","timestamp":1749927877000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001868"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001868","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"2020-06-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}