{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T05:30:01Z","timestamp":1780551001854,"version":"3.54.1"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Intra-articular screw cut-out is a common complication after proximal humerus fracture (PHF) fixation using a locking plate. This study investigates novel technical factors associated with mechanical failures and complications in PHF fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>A retrospective radiological study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients\/Participants:<\/jats:title>\n            <jats:p>Clinical and radiological data from consecutive PHF patients treated between January 2007 and December 2013 were reviewed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>Open reduction and internal fixation with the Synthes Philos locking plate.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurements:<\/jats:title>\n            <jats:p>Postoperative radiographs were assessed for quality of initial reduction, humeral head offset, screw length, number and position, restoration of medial calcar support or the presence of calcar screws, and intra-articular screw perforations. Using SliceOMatic software, we validated a method to accurately identify screws of 45 mm or longer on AP radiographs. Follow-up radiographs were reviewed for complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Among 110 patients included [mean age 60 years, 78 women (71%), follow-up 2.5 years] and the following factors were associated with a worse outcome. (1) Screws &gt;45 mm in proximal rows [Odds Ratio (OR) = 5.3 for screw cut-out); (2) lateral translation of the humeral diaphysis over 6 mm (OR = 2.7 for loss of reduction); (3) lack in medial support by bone contact (OR = 4.9 for screw cut-out); (4) varus reduction increased the risk of complications (OR = 4.3).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The importance of reduction and calcar support in PHF fixation is critical. This study highlights some technical factors to which the surgeon must pay attention: avoid varus reduction, maximize medial support, avoid screws longer than 45 mm in the proximal rows, and restore the humeral offset within 6 mm or less.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of evidence:<\/jats:title>\n            <jats:p>Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000001984","type":"journal-article","created":{"date-parts":[[2020,11,9]],"date-time":"2020-11-09T02:00:10Z","timestamp":1604887210000},"page":"259-264","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Novel Technical Factors Affecting Proximal Humerus Fixation Stability"],"prefix":"10.1097","volume":"35","author":[{"given":"G-Yves","family":"Laflamme","sequence":"first","affiliation":[{"name":"Department of Orthopedic surgery, H\u00f4pital du Sacr\u00e9-C\u0153ur de Montr\u00e9al (HSCM) Research center, Montreal, QC, Canada; and"},{"name":"Department of Surgery, Universit\u00e9 de Montr\u00e9al, Edouard-Montpetit, Montreal, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Moisan","sequence":"additional","affiliation":[{"name":"Department of Surgery, Universit\u00e9 de Montr\u00e9al, Edouard-Montpetit, Montreal, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julien","family":"Chapleau","sequence":"additional","affiliation":[{"name":"Department of Orthopedic surgery, H\u00f4pital du Sacr\u00e9-C\u0153ur de Montr\u00e9al (HSCM) Research center, Montreal, QC, Canada; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julien","family":"Goulet","sequence":"additional","affiliation":[{"name":"Department of Surgery, Universit\u00e9 de Montr\u00e9al, Edouard-Montpetit, Montreal, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"St\u00e9phane","family":"Leduc","sequence":"additional","affiliation":[{"name":"Department of Orthopedic surgery, H\u00f4pital du Sacr\u00e9-C\u0153ur de Montr\u00e9al (HSCM) Research center, Montreal, QC, Canada; and"},{"name":"Department of Surgery, Universit\u00e9 de Montr\u00e9al, Edouard-Montpetit, Montreal, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benoit","family":"Benoit","sequence":"additional","affiliation":[{"name":"Department of Orthopedic surgery, H\u00f4pital du Sacr\u00e9-C\u0153ur de Montr\u00e9al (HSCM) Research center, Montreal, QC, Canada; and"},{"name":"Department of Surgery, Universit\u00e9 de Montr\u00e9al, Edouard-Montpetit, Montreal, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominique M.","family":"Rouleau","sequence":"additional","affiliation":[{"name":"Department of Orthopedic surgery, H\u00f4pital du Sacr\u00e9-C\u0153ur de Montr\u00e9al (HSCM) Research center, Montreal, QC, Canada; and"},{"name":"Department of Surgery, Universit\u00e9 de Montr\u00e9al, Edouard-Montpetit, Montreal, QC, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1007\/s11657-015-0209-4","article-title":"Epidemiology of proximal humerus fractures","volume":"10","author":"Launonen","year":"2015","journal-title":"Arch Osteoporos."},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.jse.2010.12.018","article-title":"Internal fixation versus nonoperative treatment of displaced 3-part proximal humeral fractures in elderly patients: a randomized controlled trial","volume":"20","author":"Olerud","year":"2011","journal-title":"J Shoulder Elbow Surg."},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/BOT.0000000000000229","article-title":"Surgical management of complex proximal humerus fractures-a systematic review of 92 studies including 4500 patients","volume":"29","author":"Gupta","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1016\/j.jse.2012.06.008","article-title":"Locking plate fixation of fractures of the proximal humerus: analysis of complications, revision strategies and outcome","volume":"22","author":"Jost","year":"2013","journal-title":"J Shoulder Elbow Surg."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"233","DOI":"10.2106\/JBJS.F.01351","article-title":"Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]","volume":"90","author":"Owsley","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","article-title":"Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis","volume":"23","author":"Brunner","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1007\/s00264-017-3652-6","article-title":"Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions","volume":"42","author":"McMillan","year":"2018","journal-title":"Int Orthop."},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1186\/1471-2474-13-167","article-title":"Conservative treatment, plate fixation, or prosthesis for proximal humeral fracture. A prospective randomized study","volume":"13","author":"Launonen","year":"2012","journal-title":"BMC Musculoskelet Disord."},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1097\/TA.0b013e31822c1b5b","article-title":"The PHILOS plate for proximal humeral fractures\u2014risk factors for complications at one year","volume":"72","author":"Spross","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"209","DOI":"10.4055\/cios.2012.4.3.209","article-title":"Locking plate for proximal humeral fracture in the elderly population: serial change of neck shaft angle","volume":"4","author":"Pawaskar","year":"2012","journal-title":"Clin Orthop Surg."},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","article-title":"Displaced proximal humeral fractures. I. Classification and evaluation","volume":"52","author":"Neer","year":"1970","journal-title":"J Bone Joint Surg Am."},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3310\/hta19240","article-title":"The ProFHER (PROximal Fracture of the Humerus: evaluation by Randomisation) trial\u2014a pragmatic multicentre randomised controlled trial evaluating the clinical effectiveness and cost-effectiveness of surgical compared with non-surgical treatment for proximal fracture of the humerus in adults","volume":"19","author":"Handoll","year":"2015","journal-title":"Health Technol Assess."},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","article-title":"Analysis of efficacy and failure in proximal humerus fractures treated with locking plates","volume":"21","author":"Agudelo","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.jse.2004.01.034","article-title":"Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus","volume":"13","author":"Hertel","year":"2004","journal-title":"J Shoulder Elbow Surg."},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","article-title":"The importance of medial support in locked plating of proximal humerus fractures","volume":"21","author":"Gardner","year":"2007","journal-title":"J Orthop Trauma."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s40634-018-0148-2","article-title":"Is global humeral head offset related to intramedullary canal width? A computer tomography morphometric study","volume":"5","author":"Barth","year":"2018","journal-title":"J Exp Orthop."},{"key":"R17-20250614","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1016\/j.jse.2017.05.003","article-title":"Defining optimal calcar screw positioning in proximal humerus fracture fixation","volume":"26","author":"Padegimas","year":"2017","journal-title":"J Shoulder Elbow Surg."},{"key":"R18-20250614","doi-asserted-by":"crossref","first-page":"1968","DOI":"10.1016\/j.jse.2015.06.028","article-title":"Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures","volume":"24","author":"Schliemann","year":"2015","journal-title":"J Shoulder Elbow Surg."},{"key":"R19-20250614","doi-asserted-by":"crossref","first-page":"321","DOI":"10.4055\/cios.2012.4.4.321","article-title":"Fixation strategies to prevent screw cut-out and malreduction in proximal humeral fracture fixation","volume":"4","author":"Namdari","year":"2012","journal-title":"Clin Orthop Surg."},{"key":"R20-20250614","doi-asserted-by":"crossref","first-page":"3300","DOI":"10.1007\/s11999-011-1949-0","article-title":"Endosteal strut augment reduces complications associated with proximal humeral locking plates","volume":"469","author":"Neviaser","year":"2011","journal-title":"Clin Orthop Relat Res."},{"key":"R21-20250614","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1177\/230949901402200104","article-title":"Outcome of locking compression plating for proximal humeral fractures: a prospective study","volume":"22","author":"Chowdary","year":"2014","journal-title":"J Orthop Surg."},{"key":"R22-20250614","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1007\/s00264-011-1410-8","article-title":"Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures\u2014results of an international multicentre study","volume":"36","author":"Konrad","year":"2012","journal-title":"Int Orthop."},{"key":"R23-20250614","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1016\/j.injury.2012.08.004","article-title":"Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus","volume":"43","author":"Matassi","year":"2012","journal-title":"Injury."},{"key":"R24-20250614","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1007\/s11999-011-2207-1","article-title":"Surgical treatment of Neer Group VI proximal humeral fractures: retrospective comparison of PHILOS and hemiarthroplasty","volume":"470","author":"Spross","year":"2012","journal-title":"Clin Orthop Relat Res."},{"key":"R25-20250614","doi-asserted-by":"crossref","first-page":"368","DOI":"10.3928\/01477447-20170925-04","article-title":"Fracture severity based on classification does not predict outcome following proximal humerus fracture","volume":"40","author":"Fisher","year":"2017","journal-title":"Orthopedics."},{"key":"R26-20250614","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1016\/j.jse.2019.02.017","article-title":"Complications after surgical treatment of proximal humerus fractures in the elderly-an analysis of complication patterns and risk factors for reverse shoulder arthroplasty and angular-stable plating","volume":"28","author":"Klug","year":"2019","journal-title":"J Shoulder Elbow Surg."},{"key":"R27-20250614","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1067\/mse.2000.107089","article-title":"Effect of screw placement on fixation in the humeral head","volume":"9","author":"Liew","year":"2000","journal-title":"J Shoulder Elbow Surg."},{"key":"R28-20250614","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/BOT.0b013e31827934c1","article-title":"Mechanisms of failure of locked-plate fixation of the proximal humerus: acoustic emissions as a novel assessment modality","volume":"27","author":"Hymes","year":"2013","journal-title":"J Orthop Trauma."},{"key":"R29-20250614","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.injury.2012.10.030","article-title":"Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates","volume":"44","author":"Somasundaram","year":"2013","journal-title":"Injury."},{"key":"R30-20250614","doi-asserted-by":"crossref","first-page":"E162","DOI":"10.1016\/j.jse.2020.01.048","article-title":"Delto-Pectoral vs Deltoid split approach for proximal HUmerus fracture fixation with locking plate","volume":"29","author":"Rouleau","year":"2020","journal-title":"J Shoulder Elbow Surg."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001984","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T19:04:42Z","timestamp":1749927882000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000001984"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000001984","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5]]},"assertion":[{"value":"2020-10-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}