{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:38:24Z","timestamp":1762508304489,"version":"3.41.0"},"reference-count":7,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Pertrochanteric femoral fractures are routinely treated with cephalomedullary nailing, with good success. In the event of nonunion, implant fatigue failure may occur. The Trigen InterTAN system (Smith &amp; Nephew, Memphis, TN) features 2 integrated cephalomedullary screws for improved rotational stability of the proximal segment. The inferior compression screw prevents rotation of the larger, superior lag screw. In the event of inferior screw breakage, the retained portion will prevent the integrated lag screw from being rotated to permit extraction. We present a case of a broken nail as well as a broken integrated screw, and describe a technique for successful implant removal.<\/jats:p>","DOI":"10.1097\/bot.0000000000002024","type":"journal-article","created":{"date-parts":[[2020,12,5]],"date-time":"2020-12-05T07:03:48Z","timestamp":1607151828000},"page":"e352-e354","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Technique for Removal of Broken InterTAN Integrated Cephalomedullary Screw"],"prefix":"10.1097","volume":"35","author":[{"given":"Bernard N.","family":"Burgesson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chad P.","family":"Coles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"113","DOI":"10.5435\/00124635-200802000-00009","article-title":"Removal of broken hardware","volume":"16","author":"Hak","year":"2008","journal-title":"J Am Acad Orthop Surg."},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s00402-014-2121-6","article-title":"Breakage of cephalomedullary nailing in operative treatment of trochanteric and subtrochanteric femoral fractures","volume":"135","author":"von R\u00fcden","year":"2015","journal-title":"Arch Orthop Trauma Surg."},{"key":"R3-20250614","first-page":"435","article-title":"Implant breakage, a rare complication with the Gamma nail. A review of 843 fractures of the proximal femur treated with a Gamma nail","volume":"70","author":"Alvarez","year":"2004","journal-title":"Acta Orthop Belg."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"e108","DOI":"10.3928\/01477447-20151222-11","article-title":"Complications after hip nailing for fractures","volume":"39","author":"Mavrogenis","year":"2016","journal-title":"Orthopedics."},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13018-018-0749-6","article-title":"Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures","volume":"13","author":"Nherera","year":"2018","journal-title":"J Orthop Surg Res."},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e31819211b2","article-title":"The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression","volume":"23","author":"Ruecker","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.injury.2016.12.014","article-title":"Removal of a broken trigen intertan intertrochanteric antegrade nail","volume":"48","author":"Zheng","year":"2017","journal-title":"Injury."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002024","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T19:03:40Z","timestamp":1749927820000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002024"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9]]},"references-count":7,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002024","relation":{},"ISSN":["0890-5339"],"issn-type":[{"type":"print","value":"0890-5339"}],"subject":[],"published":{"date-parts":[[2021,9]]},"assertion":[{"value":"2020-11-17","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}