{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T00:42:43Z","timestamp":1792197763007,"version":"4.4.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Management of segmental long bone defects is a complex and challenging undertaking for orthopaedic surgeons. These defects can be encountered in cases of high-energy trauma, tumor resection, or infection, and they are often associated with significant soft tissue injury. Traditional approaches of bone transport rely on external fixation and principles of distraction osteogenesis. Plate-assisted bone segment transport (PABST) using the Precice limb lengthening nail has been adapted for use in bone transport with the use of a plate in an effort to eliminate the need for external fixation and its associated complications. Recently, the arrival of the Precice Bone Transport (PBT) System intramedullary nail eliminates the need for plating and some of the problems encountered in PABST; however, it also introduces some new issues. PABST and the PBT nail have become viable alternatives to bone transport using a frame; however, each has its own unique set of advantages and disadvantages. Although the problems of using external fixation devices are eliminated with these techniques, there is less forgiveness in execution and very little chance of correcting as the transport is underway. The arrival of the PBT nail does not eliminate the need for PABST as seen by the difficulty maintaining alignment in short metaphyseal segments. This review reflects the current state of these methods based on available evidence; however, optimization of the protocol for transport using PABST and the PBT nail will require additional cases and data.<\/jats:p>","DOI":"10.1097\/bot.0000000000002123","type":"journal-article","created":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T17:20:23Z","timestamp":1631899223000},"page":"S19-S24","source":"Crossref","is-referenced-by-count":32,"title":["Plate-Assisted Bone Segment Transport Versus Precice Bone Transport Nail"],"prefix":"10.1097","volume":"35","author":[{"given":"Matthew P.","family":"Gardner","sequence":"first","affiliation":[{"name":"Division of Orthopaedic Surgery, Department of Surgery, Southern Illinois University School of Medicine, Springfield, IL; and"},{"name":"Springfield Clinic Orthopedic Group, Springfield, IL."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Austin M.","family":"Beason","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Surgery, Department of Surgery, Southern Illinois University School of Medicine, Springfield, IL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"365","DOI":"10.2106\/00004623-198769030-00007","article-title":"The reconstruction of defects in the femoral shaft with vascularized transfers of fibular bone","volume":"69","author":"Jupiter","year":"1987","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.ocl.2009.07.011","article-title":"The concept of induced membrane for reconstruction of long bone defects","volume":"41","author":"Masquelet","year":"2010","journal-title":"Orthop Clin North Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1097\/00003086-198904000-00017","article-title":"Ilizarov treatment of tibial nonunions with bone loss","volume":"241","author":"Paley","year":"1989","journal-title":"Clin Orthop Relat Res."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1302\/0301-620X.73B2.2005164","article-title":"Compound tibial fractures with bone loss treated by the Ilizarov technique","volume":"73","author":"Dagher","year":"1991","journal-title":"J Bone Joint Surg Br"},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.otsr.2011.11.002","article-title":"Bone transport techniques in posttraumatic bone defects","volume":"98","author":"Rigal","year":"2012","journal-title":"Orthop Traumatol Surg Res."},{"key":"R6-20230828","first-page":"143","article-title":"Management of segmental bone defects","volume":"23","author":"Mauffrey","year":"2015","journal-title":"J Am Acad Orthop Surg."},{"key":"R7-20230828","first-page":"7","article-title":"Basic principles of transosseous compression and distraction osteosynthesis","volume":"32","author":"Ilizarov","year":"1971","journal-title":"Orthop Traumatol Protez"},{"key":"R8-20230828","first-page":"223","article-title":"Treatment of septic or non-septic diaphyseal pseudoarthroses by Ilizarov's monofocal compression method","volume":"71","author":"Cattaneo","year":"1985","journal-title":"Rev Chir Orthop Reparatrice Appar Mot."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/00003086-199001000-00011","article-title":"Problems, obstacles, and complications of limb lengthening by the Ilizarov technique","volume":"250","author":"Paley","year":"1990","journal-title":"Clin Orthop Relat Res"},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s11751-010-0085-9","article-title":"Bone transport using the Ilizarov method: a review of complications in 100 consecutive cases","volume":"5","author":"Iacobellis","year":"2010","journal-title":"Strateg Trauma Limb Reconstr"},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"e477","DOI":"10.5435\/JAAOS-D-17-00487","article-title":"Novel surgical approach to segmental bone transport using a magnetic intramedullary limb lengthening system","volume":"26","author":"Barinaga","year":"2018","journal-title":"J Am Acad Orthop Surg."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"e064","DOI":"10.5435\/JAAOSGlobal-D-19-00064","article-title":"Plate-assisted bone segment transport with motorized lengthening nails and locking plates: a technique to treat femoral and tibial bone defects","volume":"3","author":"Olesen","year":"2019","journal-title":"JAAOS Glob Res Rev."},{"key":"R13-20230828","first-page":"e1","article-title":"Femoral bone transport with a combined method using a PRECICE nail and cable lengthening technique","author":"Quinnan","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R14-20230828","first-page":"e1","article-title":"Plate-assisted bone segment transport with a remote-controlled magnetic intramedullary nail","author":"Wyrick","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1586\/17434440.2015.1005604","article-title":"PRECICE intramedullary limb lengthening system","volume":"12","author":"Paley","year":"2015","journal-title":"Expert Rev Med Devices"},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1302\/0301-620X.99B2.BJJ-2016-0271.R1","article-title":"Computer hexapod-assisted orthopaedic surgery provides a predictable and safe method of femoral deformity correction","volume":"99-B","author":"Hughes","year":"2017","journal-title":"Bone Joint J"},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"e43","DOI":"10.1097\/BOT.0000000000000726","article-title":"Effectiveness of treatment for distal tibial nonunions with associated complex deformities using a hexapod external fixator","volume":"31","author":"Arvesen","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"e12","DOI":"10.1097\/BOT.0000000000001005","article-title":"Hexapod stacked transport for tibial infected nonunions with bone loss: long-term functional outcomes","volume":"32","author":"Napora","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1016\/j.injury.2017.03.043","article-title":"Blocking screws for alignment control in intramedullary limb lengthening","volume":"48","author":"Furmetz","year":"2017","journal-title":"Injury"},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"e385","DOI":"10.1097\/BOT.0000000000001555","article-title":"The size of intramedullary fixation affects endochondral-mediated angiogenesis during fracture repair","volume":"33","author":"Yuasa","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"241","DOI":"10.5435\/JAAOS-D-16-00573","article-title":"Simultaneous acute femoral deformity correction and gradual limb lengthening using a retrograde femoral nail: technique and clinical results","volume":"26","author":"Iobst","year":"2018","journal-title":"J Am Acad Orthop Surg."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1007\/s11751-016-0265-3","article-title":"The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery","volume":"11","author":"Muthusamy","year":"2016","journal-title":"Strat Trauma Limb Recon"},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/00003086-199001000-00003","article-title":"Clinical application of the tension-stress effect for limb lengthening","volume":"250","author":"Ilizarov","year":"1990","journal-title":"Clinical Orthopaedics Related Research"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002123","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T18:01:07Z","timestamp":1693245667000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002123"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002123","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}