{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T11:47:44Z","timestamp":1693309664257},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,8]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>For the treatment of proximal humerus fractures, the intramedullary nitinol scaffold is a novel implant that has gained popularity and demonstrated promising 1-year outcomes as an alternative to bone grafting for providing intramedullary structural support to the humeral head. The aim of this video is to demonstrate the insertion of this device safely, while highlighting potential pitfalls, in a 67-year-old patient with a displaced, varus angulated 2-part proximal humerus fracture.<\/jats:p>","DOI":"10.1097\/bot.0000000000002177","type":"journal-article","created":{"date-parts":[[2021,7,6]],"date-time":"2021-07-06T12:53:18Z","timestamp":1625575998000},"page":"S1-S2","source":"Crossref","is-referenced-by-count":0,"title":["Proximal Humerus Fracture\u2014Open Reduction Internal Fixation With an Expandable Intramedullary Nitinol Scaffold"],"prefix":"10.1097","volume":"35","author":[{"given":"Davis","family":"Rogers","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Micheal","family":"Raad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Uma","family":"Srikumaran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Babar","family":"Shafiq","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/BF01623273","article-title":"Changing incidence and residual lifetime risk of common osteoporosis-related fractures","volume":"3","author":"Laurizen","year":"1993","journal-title":"Osteoporos Int."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/01.blo.0000194672.79634.78","article-title":"Update in the epidemiology of proximal humeral fractures","volume":"442","author":"Palvanen","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","article-title":"Displaced proximal hurneral fractures","volume":"52","author":"Neer","year":"1970","journal-title":"J Bone Joint Surg Am."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1080\/00016470310017992","article-title":"Minimally displaced proximal humeral fractures Epidemiology and outcome in 507 cases","volume":"74","author":"Gaebler","year":"2003","journal-title":"Acta Orthop Scand."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"203","DOI":"10.2106\/00004623-199702000-00006","article-title":"Functional outcome after minimally displaced fractures of the proximal part of the humerus","volume":"79","author":"Koval","year":"1997","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1186\/s12891-018-2223-3","article-title":"Open reduction internal fixation vs non- operative management in proximal humerus fractures: a prospective, randomized controlled trial protocol","volume":"19","author":"Howard","year":"2018","journal-title":"BMC Musculoskelet Disord."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1007\/s11420-010-9194-8","article-title":"Evidence for success with locking plates for fragility fractures","volume":"7","author":"Cornell","year":"2011","journal-title":"HSS J."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1186\/s12891-017-1421-8","article-title":"Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures","volume":"18","author":"Hsiao","year":"2017","journal-title":"BMC Musculoskelet Disord."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/2325967116656829","article-title":"Fibular strut graft augmentation for open reduction and internal fixation of proximal humerus fractures a systematic review and the authors \u2019 preferred surgical technique","volume":"4","author":"Saltzman","year":"2016","journal-title":"Orthop J Sports Med."},{"key":"R10-20230828","first-page":"4","article-title":"Fixation of a proximal humeral fracture using a novel intramedullary gage construct following a failed conservative treatment","volume":"2017","author":"Macy","year":"2017","journal-title":"Case Rep Orthop."},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"S131","DOI":"10.1016\/j.jse.2019.05.002","article-title":"Three- and 4-part proximal humeral fracture fixation with an intramedullary cage: 1-year clinical and radiographic outcomes","volume":"28","author":"Hudgens","year":"2019","journal-title":"J Shoulder Elb Surg."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/BOT.0000000000001712","article-title":"Intramedullary cage fixation for proximal humerus fractures has low reoperation rates at 1 year: results of a multicenter study","volume":"34","author":"Goodnough","year":"2020","journal-title":"J Orthop Trauma."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"e1900565","DOI":"10.2106\/JBJS.CC.19.00565","article-title":"Intramedullary cage removal for a consolidated proximal humerus fracture","volume":"10","author":"Nayar","year":"2020","journal-title":"JBJS Case Connect."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002177","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T19:01:46Z","timestamp":1693249306000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002177"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002177","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8]]}}}