{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T09:28:56Z","timestamp":1784366936096,"version":"3.55.0"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Despite the popularity and success of volar fixed angle plating, variations in distal radius fracture presentation underscore the importance of understanding different surgical treatment options to maximize patient outcomes. The 3-column theory of wrist mechanics provided the foundation for using a column-specific fixation approach. Implant placement within the ulnar column can be challenging because of anatomical constraints. Some have described \u201csafe zones\u201d for implant position to decrease the potential for tendon impingement. A thorough understanding of the surrounding anatomy can allow fixation decisions based on fracture fragment location. Literature reports have shown excellent results when using fragment specific fixation constructs and similar outcomes when comparing these constructs with volar locked plating. Achieving optimal outcomes in surgically treated distal radius fractures requires the surgeon to be competent along a spectrum of surgical approaches and fixation constructs.<\/jats:p>","DOI":"10.1097\/bot.0000000000002203","type":"journal-article","created":{"date-parts":[[2021,8,20]],"date-time":"2021-08-20T21:00:18Z","timestamp":1629493218000},"page":"s17-s20","source":"Crossref","is-referenced-by-count":7,"title":["Column-Specific Distal Radius Fracture Fixation"],"prefix":"10.1097","volume":"35","author":[{"given":"Nathan A.","family":"Hoekzema","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximino","family":"Brambila","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1053\/jhsu.2001.26322","article-title":"The Frequency and epidemiology of hand and forearm fractures in the United States","volume":"26","author":"Chung","year":"2001","journal-title":"J Hand Surg"},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1302\/0301-620X.78B4.0780588","article-title":"Fractures of the distal end of the radius treated by internal fixation and early function: a preliminary report of 20 cases","volume":"784","author":"Rikli","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"R3-20230828","first-page":"165","article-title":"Immediate internal fixation and motion of comminuted distal radius fractures using a new fragment specific fixation system","volume":"22","author":"Medoff","year":"1998","journal-title":"Orthop Trans"},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1142\/S0218810400000223","article-title":"The treatment of unstable distal radius fractures with volar fixation","volume":"5","author":"Orbay","year":"2000","journal-title":"Hand Surg"},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1016\/j.jhsa.2006.07.004","article-title":"The outcome of intra-articular distal radius fractures treated with fragment-specific fixation","volume":"31","author":"Benson","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1097\/BTH.0000000000000139","article-title":"The EFCR approach and the radial septum-understanding the anatomy and improving volar exposure for distal radius fractures: imagine what you could do with an extra inch","volume":"20","author":"Orbay","year":"2016","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"328","DOI":"10.2106\/JBJS.J.00193","article-title":"Volar locking plate implant prominence and flexor tendon rupture","volume":"93","author":"Soong","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.jhsa.2008.11.016","article-title":"Reconstruction of the distal ulna: instability, impaction, impingement, and arthrosis","volume":"34","author":"Greenberg","year":"2009","journal-title":"J Hand Surg Am"},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1055\/s-0035-1556864","article-title":"Anatomic considerations for plating of the distal ulna","volume":"4","author":"Hazel","year":"2015","journal-title":"J Wrist Surg"},{"key":"R10-20230828","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1097\/PRS.0b013e3181891677","article-title":"A comparative study of fragment-specific versus volar plate fixation of distal radius fractures","volume":"122","author":"Sammer","year":"2008","journal-title":"Plast Reconstr Surg"},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jhsa.2016.12.001","article-title":"Fragment-specific fixation versus volar locking plates in primarily nonreducible or secondarily re-displaced distal radius fractures: a randomized controlled study","volume":"42","author":"Landgren","year":"2017","journal-title":"J Hand Surg Am"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002203","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T19:00:35Z","timestamp":1693249235000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002203"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002203","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2021,9]]}}}