{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T03:15:08Z","timestamp":1782962108267,"version":"3.54.5"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>Imaging of the distal radius is of paramount importance in diagnosing injuries, indicating patients for operative or nonoperative treatment, and appropriately following patients for associated injuries and complications. Plain radiographs and fluoroscopy are the dominant imaging modalities in all settings because they are readily available and provide valuable information about the osseous structures and any instrumentation. Computed tomography can offer more information about implant placement and the level of comminution of the articular surfaces but is more expensive and exposes patients to higher doses of radiation. Magnetic resonance imaging is less commonly used but is useful for occult fractures and other associated injuries. Ultrasonography is gaining popularity in evaluating implant placement, especially regarding tendon impingement and subsequent tendon injury.<\/jats:p>","DOI":"10.1097\/bot.0000000000002206","type":"journal-article","created":{"date-parts":[[2021,8,20]],"date-time":"2021-08-20T21:00:59Z","timestamp":1629493259000},"page":"s21-s26","source":"Crossref","is-referenced-by-count":4,"title":["Radiography of the Distal Radius"],"prefix":"10.1097","volume":"35","author":[{"given":"Robert R. L.","family":"Gray","sequence":"first","affiliation":[{"name":"NorthShore Orthopaedic Institute, Skokie, IL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory","family":"Foremny","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital for Special Surgery, Manhattan, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital for Special Surgery, Manhattan, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tate","family":"Greditzer","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital for Special Surgery, Manhattan, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.hcl.2005.02.008","article-title":"Essential radiographic evaluation for distal radius fractures","volume":"21","author":"Medoff","year":"2005","journal-title":"Hand Clin."},{"key":"R2-20230828","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1016\/j.jhsa.2004.06.008","article-title":"Assessment of instability factors in adult distal radius fractures","volume":"29","author":"Nesbitt","year":"2004","journal-title":"J Hand Surg Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1055\/s-0038-1673406","article-title":"Carpal alignment: a new method for assessment","volume":"8","author":"Selles","year":"2019","journal-title":"J Wrist Surg."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"797.e1","DOI":"10.1016\/j.jhsa.2018.10.024","article-title":"The Capitate-to-Axis-of-Radius Distance (CARD): a new radiographic measurement for wrist and carpal alignment in the sagittal plane","volume":"44","author":"Kuhnel","year":"2019","journal-title":"J Hand Surg Am."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1177\/1753193418822470","article-title":"The correlation between the teardrop angle and anterior lunate facet displacement in plating distal radial fractures","volume":"44","author":"Teunis","year":"2019","journal-title":"J Hand Surg Eur."},{"key":"R6-20230828","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/0020-1383(89)90113-7","article-title":"Stability assessment of distal radius fractures","volume":"20","author":"Lafontaine","year":"1989","journal-title":"Injury"},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1302\/0301-620X.93B2.25631","article-title":"What are the radiological predictors of functional outcome following fractures of the distal radius?","volume":"93","author":"Ng","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00256-012-1451-0","article-title":"Explorative study of the sensitivity and specificity of the pronator quadratus fat pad sign as a predictor of subtle wrist fractures","volume":"42","author":"Fallahi","year":"2013","journal-title":"Skeletal Radiol."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"359","DOI":"10.4329\/wjr.v9.i9.359","article-title":"Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures","volume":"9","author":"Loesaus","year":"2017","journal-title":"World J Radiol."},{"issue":"suppl 6","key":"R10-20230828","first-page":"S21","article-title":"Is it really necessary to restore radial anatomic parameters after distal radius fractures?","volume":"45","author":"Dario","year":"2014","journal-title":"Injury"},{"key":"R11-20230828","doi-asserted-by":"crossref","first-page":"6598","DOI":"10.12659\/MSM.915824","article-title":"The necessity of restoration of radiologic parameters by closed reduction in elderly patients with distal radius fractures","volume":"25","author":"Kong","year":"2019","journal-title":"Med Sci Monit."},{"key":"R12-20230828","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1053\/jhsu.1999.0249","article-title":"Tilted lateral radiographs in the evaluation of intra-articular distal radius fractures","volume":"24","author":"Lundy","year":"1999","journal-title":"J Hand Surg Am."},{"key":"R13-20230828","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jhsa.2003.09.004","article-title":"Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation","volume":"29","author":"Boyer","year":"2004","journal-title":"J Hand Surg Am."},{"key":"R14-20230828","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.1016\/j.jhsa.2008.07.021","article-title":"Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study","volume":"33","author":"Soong","year":"2008","journal-title":"J Hand Surg Am."},{"key":"R15-20230828","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.jhsa.2013.03.011","article-title":"Volar plate position and flexor tendon rupture following distal radius fracture fixation","volume":"38","author":"Kitay","year":"2013","journal-title":"J Hand Surg Am."},{"key":"R16-20230828","doi-asserted-by":"crossref","first-page":"328","DOI":"10.2106\/JBJS.J.00193","article-title":"Volar locking plate implant prominence and flexor tendon rupture","volume":"93","author":"Soong","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"R17-20230828","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/BTO.0000000000000318","article-title":"Radiographic evaluation of the distal radioulnar joint: technique to detect sigmoid notch intra-articular screw breach in distal radius Fractures","volume":"35","author":"Klein","year":"2020","journal-title":"Tech Orthop."},{"key":"R18-20230828","doi-asserted-by":"crossref","first-page":"2523","DOI":"10.2106\/JBJS.I.01617","article-title":"Comparative evaluation of postreduction intra-articular distal radial fractures by radiographs and multidetector computed tomography","volume":"92","author":"Arora","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R19-20230828","doi-asserted-by":"crossref","first-page":"83","DOI":"10.4055\/cios.2012.4.1.83","article-title":"Evaluation of the sigmoid notch involvement in the intra-articular distal radius fractures: the efficacy of computed tomography compared with plain X-ray","volume":"4","author":"Heo","year":"2012","journal-title":"Clin Orthop Surg."},{"key":"R20-20230828","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1302\/2046-3758.412.2000433","article-title":"Spectrum bias, a common unrecognized issue in orthopaedic agreement studies: do CT scans really influence the agreement on treatment plans in fractures of the distal radius?","volume":"4","author":"Kleinlugtenbelt","year":"2015","journal-title":"Bone Joint Res"},{"key":"R21-20230828","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1055\/s-0039-1681026","article-title":"Volar plating: imaging modalities for the detection of screw penetration","volume":"8","author":"Bergsma","year":"2019","journal-title":"J Wrist Surg."},{"key":"R22-20230828","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1007\/s11552-015-9779-2","article-title":"Scapholunate instability after distal radius volar plating","volume":"10","author":"Jones","year":"2015","journal-title":"Hand (N Y)."},{"key":"R23-20230828","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1007\/s002560050375","article-title":"MRI of fractures of the distal radius: comparison with conventional radiographs","volume":"27","author":"Spence","year":"1998","journal-title":"Skeletal Radiol."},{"key":"R24-20230828","first-page":"703790","article-title":"Magnetic resonance imaging visualizes median nerve entrapment due to radius fracture and allows immediate surgical release","volume":"2015","author":"Yanagibayashi","year":"2015","journal-title":"Case Rep Orthop."},{"key":"R25-20230828","doi-asserted-by":"crossref","first-page":"835.e1","DOI":"10.1016\/j.jhsa.2017.05.032","article-title":"Predictive Power of distal radial metaphyseal tenderness for diagnosing occult fracture","volume":"42","author":"Glickel","year":"2017","journal-title":"J Hand Surg Am."},{"key":"R26-20230828","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.aott.2017.10.004","article-title":"Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration","volume":"51","author":"Gurbuz","year":"2017","journal-title":"Acta Orthop Traumatol Turc"},{"key":"R27-20230828","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1308\/rcsann.2016.0045","article-title":"Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study","volume":"98","author":"Williams","year":"2016","journal-title":"Ann R Coll Surg Engl."},{"key":"R28-20230828","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1186\/s13018-018-0774-5","article-title":"Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation","volume":"13","author":"Oc","year":"2018","journal-title":"J Orthop Surg Res."},{"key":"R29-20230828","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.jhsa.2015.11.022","article-title":"Ultrasonic evaluation of the flexor pollicis longus tendon following volar plate fixation for distal radius fractures","volume":"41","author":"Kara","year":"2016","journal-title":"J Hand Surg Am."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002206","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T19:00:40Z","timestamp":1693249240000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002206"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002206","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2021,9]]}}}