{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T14:45:35Z","timestamp":1787237135304,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To compare infection rates after second-stage definitive surgery for high-energy tibial plateau fractures between groups of patients who had the external fixator prepped into the surgical field and those who did not.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Retrospective cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Two academic Level 1 trauma centers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients\/Participants:<\/jats:title>\n                    <jats:p>Two hundred forty-four patients met inclusion and exclusion criteria between the 2 institutions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Intervention:<\/jats:title>\n                    <jats:p>Prepping of the external fixator into the surgical field during second-stage definitive open reduction and internal fixation. 162 patients were in the prepped group, and 82 patients were in the nonprepped group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcome Measurements:<\/jats:title>\n                    <jats:p>The primary outcome was the rate of deep infection after definitive fixation. Secondary outcome was operative time.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      There were no significant differences in infection rates between prepped (11.7%) and nonprepped (18.3%) groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.162). Patients in the prepped groups had significantly decreased operative time (168.2 minutes vs. 221.9 minutes,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001) even after controlling for confounders in regression analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>There is no increased risk of infection associated with prepping and maintenance of the external fixator during definitive internal fixation for high-energy tibial plateau fractures. These data suggest that this practice may lead to shorter operative times as well.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000002371","type":"journal-article","created":{"date-parts":[[2022,4,25]],"date-time":"2022-04-25T18:00:09Z","timestamp":1650909609000},"page":"530-534","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Are Infection Rates Increased After Sterilization of the External Fixator During Staged Internal Fixation of High-Energy Tibial Plateau Fractures?"],"prefix":"10.1097","volume":"36","author":[{"given":"Tyler James","family":"Moon","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucas","family":"Haase","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas","family":"Haase","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, KA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Ochenjele","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brent","family":"Wise","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, KA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Napora","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1097\/01.bot.0000171881.11205.80","article-title":"Staged management of high-energy proximal tibia fractures (OTA types 41): the results of a prospective, standardized protocol","volume":"19","author":"Egol","year":"2005","journal-title":"J Orthop Trauma."},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1007\/s00590-018-2135-9","article-title":"Perioperative management of external fixation in staged protocols: an international survey","volume":"28","author":"Hodel","year":"2018","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"86","DOI":"10.5435\/00124635-199503000-00004","article-title":"Tibial Plateau fractures: evaluation and treatment","volume":"3","author":"Koval","year":"1995","journal-title":"J Am Acad Orthop Surg."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"e102","DOI":"10.1097\/BOT.0000000000001050","article-title":"Is it safe to prep the external fixator in situ during second-stage pilon surgical treatment?","volume":"32","author":"Nielsen","year":"2018","journal-title":"J Orthop Trauma."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1016\/j.injury.2016.07.009","article-title":"Can applied external fixators be sterilized for surgery? A prospective cohort study of orthopaedic trauma patients","volume":"47","author":"Hardeski","year":"2016","journal-title":"Injury."},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1097\/TA.0b013e31823c97f5","article-title":"Bacteria on external fixators: which prep is best?","volume":"72","author":"Stinner","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1016\/j.injury.2005.05.006","article-title":"The effectiveness of standard povidone iodine surgical preparation in decontaminating external fixator components","volume":"36","author":"Hak","year":"2005","journal-title":"Injury."},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.jss.2018.03.022","article-title":"Prolonged operative duration is associated with complications: a systematic review and meta-analysis","volume":"229","author":"Cheng","year":"2018","journal-title":"J Surg Res."},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.injury.2012.10.032","article-title":"Prolonged operative time increases infection rate in tibial plateau fractures","volume":"44","author":"Colman","year":"2013","journal-title":"Injury."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"2256","DOI":"10.1016\/j.arth.2018.02.037","article-title":"Impact of operative time on adverse events following primary total joint arthroplasty","volume":"33","author":"Bohl","year":"2018","journal-title":"J Arthroplasty."},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.arth.2018.11.015","article-title":"The association between operative time and short-term complications in total hip arthroplasty: an analysis of 89,802 surgeries","volume":"34","author":"Surace","year":"2019","journal-title":"J Arthroplasty."},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3928\/01477447-20201119-01","article-title":"Increase in operative time is associated with postoperative complications in revision total knee arthroplasty","volume":"44","author":"Chen","year":"2021","journal-title":"Orthopedics."},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"S7","DOI":"10.1016\/j.jor.2015.01.026","article-title":"Risk factors of deep infection in operatively treated pilon fractures (AO\/OTA: 43)","volume":"12","author":"Molina","year":"2015","journal-title":"J Orthop."},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1097\/BOT.0000000000000918","article-title":"OTA\/AO classification is highly predictive of acute compartment syndrome after tibia fracture: a cohort of 2885 fractures","volume":"31","author":"Beebe","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1097\/00005131-200011000-00003","article-title":"Outcome validation of the AO\/OTA fracture classification system","volume":"14","author":"Swiontkowski","year":"2000","journal-title":"J Orthop Trauma."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1007\/s00590-013-1252-8","article-title":"Surgical site infection after open reduction and internal fixation of tibial plateau fractures","volume":"24","author":"Lin","year":"2014","journal-title":"Eur J Orthop Surg Traumatol."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002371","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:01:06Z","timestamp":1749913266000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002371"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":16,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002371","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10]]},"assertion":[{"value":"2022-03-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}