{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,28]],"date-time":"2026-06-28T06:21:23Z","timestamp":1782627683406,"version":"3.54.5"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To describe malreduction of supracondylar distal femur fractures stabilized with lateral femoral locking plates and determine whether a mismatch in axial lateral distal femur anatomy and lateral distal femoral plate design contributes to supracondylar distal femoral fracture malreduction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>OTA\/AO 33A were simulated in 7 cadaver femurs and fixed with a lateral distal locking femoral plate placed flush to the lateral femoral condyle (group 1). In group 2, the anterior flange of the plate was externally rotated 10 degrees in relation to the lateral condyle. A motion capture system measured translation and rotation of the articular segment as shaft screws were applied, reducing plate to femoral diaphysis. Articular segment movement was compared between groups using paired Student <jats:italic toggle=\"yes\">t<\/jats:italic> test, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05. A large database of 3D scans of 800 femurs was used to define the relationship of the lateral femoral condyle to the lateral cortical surface of the human femur.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Malreduction was observed with anatomic plate application results from medial translation (17 mm) and external rotation (12.2 degrees) (group 1). Modifying plate geometry to match lateral femur anatomy (group 2) improved medial translation by 46% and external rotation by 80%. An analysis of the shape of the 800 distal femurs showed that the average posterior anterior inclination is 16.5 degrees.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Anatomic application of distal femoral plates results in significant malreduction. Modifying the plate design to accommodate 10 degrees slope of lateral distal femur results in partial correction of deformity. Future studies should investigate other means of correcting the malalignment, especially considering the 16.5-degree posterior anterior inclination of the condyle.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002373","type":"journal-article","created":{"date-parts":[[2022,4,18]],"date-time":"2022-04-18T17:00:08Z","timestamp":1650301208000},"page":"515-518","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":19,"title":["Axial and Rotational Malreduction (Golf Club Deformity) in Distal Femur Fractures"],"prefix":"10.1097","volume":"36","author":[{"given":"Jason","family":"Lowe","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Arizona, Tucson, AZ;"},{"name":"Department of Orthopaedic Surgery, Banner University Medical Center, Tucson, AZ;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Alhandi","sequence":"additional","affiliation":[{"name":"King Abdulaziz Medical City, Riyadh, Saudi Arabia;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aditya","family":"Manoharan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of Arizona, Tucson, AZ;"},{"name":"Department of Orthopaedic Surgery, Banner University Medical Center, Tucson, AZ;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Ouellette","sequence":"additional","affiliation":[{"name":"Miami Orthopedics and Sports Medicine Group, Baptist Health of South Florida, Coral Gables, FL;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Kaimrajh","sequence":"additional","affiliation":[{"name":"Max Biedermann Institute for Biomechanics, Mount Sinai, Miami Beach, FL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward","family":"Milne","sequence":"additional","affiliation":[{"name":"Max Biedermann Institute for Biomechanics, Mount Sinai, Miami Beach, FL; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Loren","family":"Latta","sequence":"additional","affiliation":[{"name":"Max Biedermann Institute for Biomechanics, Mount Sinai, Miami Beach, FL; and"},{"name":"Department of Orthopaedics, University of Miami, Miami, FL."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1097\/00005131-199710000-00010","article-title":"Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate","volume":"11","author":"Koval","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1097\/00005131-200408000-00009","article-title":"Avoiding malunion with 95degrees fixed-angle distal femoral implants","volume":"18","author":"Karunakar","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s00402-004-0779-x","article-title":"Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study","volume":"125","author":"Sch\u00fctz","year":"2005","journal-title":"Arch Orthop Trauma Surg."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/BOT.0b013e318234d460","article-title":"Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures","volume":"26","author":"Vallier","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1097\/BOT.0b013e31821d7a56","article-title":"Pitfalls in the application of distal femur plates for fractures","volume":"25","author":"Collinge","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"suppl 3","key":"R6-20250614","doi-asserted-by":"crossref","first-page":"Sc32","DOI":"10.1016\/S0020-1383(01)00182-6","article-title":"Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results","volume":"32","author":"Kregor","year":"2001","journal-title":"Injury"},{"issue":"suppl 1","key":"R7-20250614","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1097\/BOT.0b013e3182070127","article-title":"Locking plates for distal femur fractures: is there a problem with fracture healing?","volume":"25","author":"Henderson","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1097\/00005131-200409000-00006","article-title":"Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures","volume":"18","author":"Kregor","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1097\/00005131-200409000-00005","article-title":"Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO\/OTA types A2, A3, C2, and C3)","volume":"18","author":"Weight","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.injury.2017.01.019","article-title":"Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures","volume":"48","author":"Kim","year":"2017","journal-title":"Injury"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/BOT.0000000000001431","article-title":"Distal femur locking plates fit poorly before and after total knee arthroplasty","volume":"33","author":"Campbell","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.injury.2020.01.009","article-title":"Analysis of the fit of modern pre-contoured distal femur plates: expect an imperfect contour","volume":"51","author":"Bedard","year":"2020","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002373","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T19:00:55Z","timestamp":1749927655000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002373"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":12,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002373","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10]]},"assertion":[{"value":"2022-03-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}