{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T22:28:24Z","timestamp":1783636104684,"version":"3.55.0"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,8]]},"abstract":"<jats:title>Summary:<\/jats:title>\n          <jats:p>The treatment of midshaft clavicle fractures continues to evolve, with a variety of fixation techniques and constructs used. Symptomatic hardware is a common complication related to plate fixation of the clavicle, and often results in secondary surgery for implant removal. The minifragment dual plate fixation technique for clavicle fractures provides a construct that may result in fewer implant related complications with comparable fixation stability to precontoured locking plates. Our case presentation demonstrates our approach to midshaft clavicle fractures, the benefits of this surgical technique, and reported outcomes from this fixation method.<\/jats:p>","DOI":"10.1097\/bot.0000000000002389","type":"journal-article","created":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T14:32:01Z","timestamp":1657895521000},"page":"S1-S2","source":"Crossref","is-referenced-by-count":3,"title":["Dual Plate Minifragment Fixation of Clavicle Fractures- Technique and Approach"],"prefix":"10.1097","volume":"36","author":[{"given":"Elizabeth","family":"Zielinski","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, Richmond, VA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keli","family":"Doe","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Virginia Commonwealth University School of Medicine, Richmond, VA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Perdue","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, Richmond, VA; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230828","doi-asserted-by":"crossref","first-page":"e468","DOI":"10.5435\/JAAOS-D-17-00442","article-title":"Management of midshaft clavicle fractures in adults","volume":"26","author":"Wiesel","year":"2018","journal-title":"J Am Acad Orthop Surg."},{"key":"R2-20230828","first-page":"1","article-title":"Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures: a multicenter, randomized clinical trial","volume":"89A","year":"2007","journal-title":"J Bone Joint Surg Am."},{"key":"R3-20230828","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.2106\/JBJS.M.00607","article-title":"Rate of and risk factors for reoperations after open reduction and internal fixation of midshaft clavicle fractures: a population-based study in Ontario, Canada","volume":"96A","author":"Leroux","year":"2014","journal-title":"J Bone Joint Surg Am."},{"key":"R4-20230828","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1007\/s00402-011-1456-5","article-title":"Systematic review of the complications of plate fixation of clavicle fractures","volume":"132","author":"Wijdicks","year":"2012","journal-title":"Arch Orthop Tzrauma Surg."},{"key":"R5-20230828","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1007\/s00402-015-2329-0","article-title":"Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation","volume":"135","author":"Prasarn","year":"2015","journal-title":"Arch Orthop Trauma Surg."},{"key":"R6-20230828","first-page":"1","article-title":"Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures","volume":"0","author":"Sheth","year":"2021","journal-title":"Shoulder Elb."},{"key":"R7-20230828","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.injury.2020.01.014","article-title":"Safety and efficiency of using 2.4\/2.4 mm and 2.0\/2.4 dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures","volume":"51","author":"Chen","year":"2020","journal-title":"Injury."},{"key":"R8-20230828","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1007\/s00402-017-2676-0","article-title":"Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures","volume":"137","author":"Chen","year":"2017","journal-title":"Arch Orthop Trauma Surg."},{"key":"R9-20230828","doi-asserted-by":"crossref","first-page":"e229","DOI":"10.1097\/BOT.0000000000001727","article-title":"Dual mini-fragment plating is comparable with pre-countoured small fragment plating for operative diaphyseal clavicle fractures: a retrospective cohort study","volume":"34","author":"DeBaun","year":"2020","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002389","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T19:12:02Z","timestamp":1693249922000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002389"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8]]},"references-count":9,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002389","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2022,8]]}}}