{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:40:05Z","timestamp":1749926405055,"version":"3.41.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To evaluate whether a single proximal interlocking bolt was sufficient during the treatment of extra-articular femur fractures with retrograde medullary nailing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective comparative study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Academic Level 1 trauma center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients:<\/jats:title>\n            <jats:p>The study included 136 patients with extra-articular femur fractures treated with retrograde medullary nailing who met inclusion and follow-up criteria.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>The intervention included surgical treatment for a femur fracture with retrograde medullary nailing, with comparisons made between those treated with a single proximal interlocking (1 IL) bolt and those treated with 2 proximal interlocking bolts (2 IL).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Main Outcome Measurement:<\/jats:title>\n            <jats:p>The main outcome measurements were as follows: (1) rate of nonunion and (2) rate of catastrophic implant failure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There was no difference in the rate of nonunion requiring surgical intervention between the 2 groups. There were no catastrophic failures in either group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>A single proximal interlocking bolt may be sufficient when using retrograde nailing for the treatment of extra-articular femur fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence:<\/jats:title>\n            <jats:p>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002439","type":"journal-article","created":{"date-parts":[[2022,6,16]],"date-time":"2022-06-16T21:00:10Z","timestamp":1655413210000},"page":"610-614","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Single Proximal Interlocking Bolt May Be Sufficient for Retrograde Nailing of Extra-articular Femur Fractures"],"prefix":"10.1097","volume":"36","author":[{"given":"Sean T.","family":"Campbell","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, UC Davis Medical Center, Sacramento, CA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ekamjeet","family":"Dhillon","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Harborview Medical Center, Seattle WA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Sliepka","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Harborview Medical Center, Seattle WA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Higgins","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Harborview Medical Center, Seattle WA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malcolm R.","family":"DeBaun","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Duke University Hospital, Durham, NC; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lawrence Henry","family":"Goodnough","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Stanford Hospital, Palo Alto, CA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julie","family":"Agel","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Harborview Medical Center, Seattle WA;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David P.","family":"Barei","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Harborview Medical Center, Seattle WA;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"S6","DOI":"10.1097\/BOT.0000000000000890","article-title":"Retrograde femoral nailing using percutaneous reduction techniques","volume":"31","author":"Pettett","year":"2017","journal-title":"J Orthop Trauma."},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.injury.2015.10.030","article-title":"Retrograde femoral nailing of periprosthetic fractures around total knee replacements","volume":"47","author":"Jones","year":"2016","journal-title":"Injury"},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/BOT.0b013e3181ad61f2","article-title":"Distal third femur fractures treated with retrograde femoral nailing and blocking screws","volume":"23","author":"Ostrum","year":"2009","journal-title":"J Orthop Trauma."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1097\/00005373-199501000-00012","article-title":"Retrograde Nailing of Femoral Shaft Fractures","volume":"38","author":"Patterson","year":"1995","journal-title":"J Trauma Inj Infect Crit Care."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/BOT.0b013e31816c0255","article-title":"Retrograde versus antegrade nailing of femoral shaft fractures","volume":"22","author":"Ricci","year":"2008","journal-title":"J Orthop Trauma."},{"key":"R6-20250614","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/00003086-199805000-00011","article-title":"Retrograde intramedullary nailing of supracondylar femoral fractures","volume":"350","author":"Helfet","year":"1998","journal-title":"Clin Orthop Relat Res."},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1097\/00013611-200112000-00005","article-title":"Complications of retrograde intramedullary nailing of the femur","volume":"16","author":"Moed","year":"2001","journal-title":"Tech Orthop."},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/00005131-200102000-00013","article-title":"Arterial injury during retrograde femoral nailing: a case report of injury to a branch of the profunda femoris artery","volume":"15","author":"Coupe","year":"2001","journal-title":"J Orthop Trauma."},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/BOT.0000000000000029","article-title":"Electromagnetic navigation reduces surgical time and radiation exposure for proximal interlocking in retrograde femoral nailing","volume":"28","author":"Somerson","year":"2014","journal-title":"J Orthop Trauma."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"e421","DOI":"10.1097\/BOT.0000000000000353","article-title":"Is there an optimal proximal locking screw length in retrograde intramedullary femoral nailing? Can we stop measuring for these screws?","volume":"29","author":"Collinge","year":"2015","journal-title":"J Orthop Trauma."},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/00005131-199808000-00002","article-title":"Neurologic and vascular structures at risk during anterior-posterior locking of retrograde femoral nails","volume":"12","author":"Riina","year":"1998","journal-title":"J Orthop Trauma."},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"e100","DOI":"10.1097\/BOT.0000000000000478","article-title":"Current opinions on fracture follow-up: a survey of OTA members regarding standards of care and implications for clinical research","volume":"30","author":"Ricci","year":"2016","journal-title":"J Orthop Trauma."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002439","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:05:19Z","timestamp":1749924319000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002439"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12]]},"references-count":12,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002439","relation":{},"ISSN":["0890-5339"],"issn-type":[{"type":"print","value":"0890-5339"}],"subject":[],"published":{"date-parts":[[2022,12]]},"assertion":[{"value":"2022-06-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}