{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T22:47:28Z","timestamp":1788216448834,"version":"build-2803163510"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,6]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To compare anterior hook plating with established fixation constructs biomechanically and report outcomes and complications in a cohort of patella fractures treated with the technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Laboratory-based biomechanical study and clinical multicenter retrospective cohort study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>2 US Level 1 trauma centers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients\/Participants:<\/jats:title>\n                    <jats:p>51 patients (28 M and 23 F) with 30 simple transverse and 21 comminuted patella fractures. Thirty-six cadaveric patellae were used for the biomechanical study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Intervention:<\/jats:title>\n                    <jats:p>Biomechanical\u2014dorsal plating was compared with cerclage wiring and modified tension band cable fixation in a comminuted patella fracture model in 36 cadaveric patellae. Constructs were tested at 0\u00b0 and 45 degrees of flexion. Clinical\u2014we reviewed a consecutive series of patella fractures in 2 centers for outcome and complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main Outcome Measurements:<\/jats:title>\n                    <jats:p>Biomechanical\u2014construct stiffness. Clinical\u2014reduction, union, complications, and range of motion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Stiffness was greatest in dorsal plating at both 0\u00b0 and 45 degrees. Dorsal plating (976 N, 1643 N) &gt; modified tension band (317 N, 297 N) &gt; cerclage (89.8 N, 150.3 N) at 0 and 45 degrees, respectively. 51 patients with patella fractures had them fixed with dorsal 2.7-mm mini fragment plates including a distal to proximal lag screw through the plate from the nose of the patella. 9 cases were small distal fragments not easily managed with screws and cables. All patients were followed up to union. There were 2 infections (1 superficial and 1 deep with nonunion), and 5 had implant removal (9.8%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Dorsal plating is biomechanically and clinically superior to modified tension band and cerclage techniques in comminuted patella fractures. This method allows for fixation of small distal pole fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bot.0000000000002565","type":"journal-article","created":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T09:31:57Z","timestamp":1675330317000},"page":"e258-e263","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Anterior Hook Plating of Patella Fractures: A Biomechanical Analysis and Clinical Series"],"prefix":"10.1097","volume":"37","author":[{"given":"Maxwell C.","family":"Alley","sequence":"first","affiliation":[{"name":"Boston Medical Center, Boston, MA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Kain","sequence":"additional","affiliation":[{"name":"Boston Medical Center, Boston, MA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean","family":"Mitchell","sequence":"additional","affiliation":[{"name":"University of Arizona, College of Medicine, Phoenix, AZ; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brock J.","family":"Walker","sequence":"additional","affiliation":[{"name":"University of Arizona, College of Medicine, Phoenix, AZ; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clifford B.","family":"Jones","sequence":"additional","affiliation":[{"name":"St. Joseph's Medical Center, Phoenix, AZ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8903-1713","authenticated-orcid":false,"given":"Paul","family":"Tornetta","sequence":"additional","affiliation":[{"name":"Boston Medical Center, Boston, MA;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1097\/TA.0b013e31825168b6","article-title":"Meta-analysis of re-operation, nonunion, and infection after open reduction and internal fixation of patella fractures","volume":"73","author":"Dy","year":"2012","journal-title":"J Trauma Acute Care Surg."},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"696","DOI":"10.2106\/00004623-200404000-00005","article-title":"Inferior patellar pole avulsion fractures: osteosynthesis compared with pole resection","volume":"86","author":"Kastelec","year":"2004","journal-title":"J Bone Joint Surg."},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1002\/jor.1100020108","article-title":"Force ratios in the quadriceps tendon and ligamentum patellae","volume":"2","author":"Huberti","year":"1984","journal-title":"J Orthop Res."},{"key":"R5-20250614","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1097\/BOT.0b013e318228c1a1","article-title":"Functional outcomes after operatively treated patella fractures","volume":"26","author":"LeBrun","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1007\/s00402-015-2241-7","article-title":"Treatment of patella fracture by claw-like shape memory alloy","volume":"135","author":"Hao","year":"2015","journal-title":"Arch Orthop Trauma Surg."},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.injury.2009.07.007","article-title":"Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures","volume":"41","author":"Dargel","year":"2010","journal-title":"Injury"},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/BOT.0000000000000787","article-title":"Superior outcomes after operative fixation of patella fractures using a novel plating technique: a prospective cohort study","volume":"31","author":"Lorich","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/00005131-200502000-00008","article-title":"Complete exposure of the articular surface for fixation of patellar fractures","volume":"19","author":"Gardner","year":"2005","journal-title":"J Orthop Trauma"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.injury.2015.02.017","article-title":"Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: a biomechanical study","volume":"46","author":"Dickens","year":"2015","journal-title":"Injury"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"e305","DOI":"10.1097\/BOT.0000000000000309","article-title":"Biomechanical assessment of locked plating for the fixation of patella fractures","volume":"29","author":"Wurm","year":"2015","journal-title":"J Orthop Trauma"},{"issue":"suppl 1","key":"R13-20250614","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1016\/S0020-1383(18)30304-8","article-title":"Treating patella fractures with a locking patella plate - first clinical results","volume":"49","author":"Wurm","year":"2018","journal-title":"Injury"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/BOT.0000000000001868","article-title":"Functional outcomes of patella fractures treated with anterior plate osteosynthesis at one year","volume":"35","author":"Shymon","year":"2021","journal-title":"J Orthop Trauma"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"e13","DOI":"10.2106\/JBJS.CC.16.00044","article-title":"Failure of patellar plating with mini-fragment implants: a case report","volume":"7","author":"Miles","year":"2017","journal-title":"JBJS Case Connect."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/j.injury.2018.03.030","article-title":"Fixed angle plate fixation of comminuted patellar fractures","volume":"49","author":"Moore","year":"2018","journal-title":"Injury"}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002565","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T14:02:56Z","timestamp":1749909776000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002565"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":14,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002565","relation":{},"ISSN":["0890-5339"],"issn-type":[{"value":"0890-5339","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6]]},"assertion":[{"value":"2023-01-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}