{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:50:38Z","timestamp":1762869038334,"version":"3.41.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>To determine the effect of linking the intramedullary nail and the laterally applied locking plate to treat comminuted distal femur fractures and allow for immediate weight bearing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Comminuted extra-articular distal femur fractures were created in 16 synthetic osteoporotic femurs and split into 2 groups: linked versus unlinked. In the linked construct, in addition to standard plate fixation and proximal locking of the nail, 2 nonthreaded locking bolts (prototypes) were placed through both the plate and the nail. In the unlinked construct, the same number of screws affixed the plate to the bone but were directed around the nail, and separate distal interlocking screws were placed for nail fixation. Each specimen underwent sequential axial and torsional loading, and axial and torsional stiffness were calculated and compared.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>On average, the unlinked constructs demonstrated a greater axial stiffness at all levels of axial loading, and linked constructs demonstrated greater average rotational stiffness. However, there were no statistically significant differences (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.189) between the linked and unlinked groups at any axial or torsional load.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>In distal femur fractures with metaphyseal comminution, there were no significant differences in axial or torsional stiffness when linking the plate to the nail. Linking the construct seems to provide no significant mechanical advantage compared with the unlinked environment, but it may be a useful strategy to reduce nail \u201ctraffic\u201d in the distal segment with no significant disadvantage.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bot.0000000000002594","type":"journal-article","created":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T21:01:01Z","timestamp":1677790861000},"page":"351-355","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Effect of Implant Linkage on Axial and Rotational Stiffness of Nail\u2013Plate Constructs for Comminuted Distal Femoral Fractures"],"prefix":"10.1097","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1491-6410","authenticated-orcid":false,"given":"Charles C.","family":"Lin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas","family":"Parody","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Utkarsh","family":"Anil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth A.","family":"Egol","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250614","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s00264-017-3665-1","article-title":"Population-based epidemiology and incidence of distal femur fractures","volume":"42","author":"Elsoe","year":"2018","journal-title":"Int Orthop."},{"key":"R2-20250614","doi-asserted-by":"crossref","first-page":"2658","DOI":"10.2106\/JBJS.F.01538","article-title":"Mortality after periprosthetic fracture of the femur","volume":"89","author":"Bhattacharyya","year":"2007","journal-title":"J Bone Joint Surg Am."},{"key":"R3-20250614","doi-asserted-by":"crossref","first-page":"e64","DOI":"10.1097\/BOT.0000000000001332","article-title":"Nail plate combination technique for native and periprosthetic distal femur fractures","volume":"33","author":"Liporace","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R4-20250614","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1080\/10255842.2010.535816","article-title":"Experimental and probabilistic analysis of distal femoral periprosthetic fracture: a comparison of locking plate and intramedullary nail fixation. Part A: experimental investigation","volume":"14","author":"Salas","year":"2011","journal-title":"Comput Methods Biomech Biomed Engin."},{"key":"R5-20250614","first-page":"443","article-title":"Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate","volume":"66","author":"Heiney","year":"2009","journal-title":"J Trauma"},{"key":"R6-20250614","first-page":"846","article-title":"Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases","volume":"88","author":"Vallier","year":"2006","journal-title":"J Bone Joint Surg Am."},{"key":"R7-20250614","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00005131-200409000-00004","article-title":"Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures","volume":"18","author":"Zlowodzki","year":"2004","journal-title":"J Orthop Trauma"},{"key":"R8-20250614","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/00005373-200001000-00015","article-title":"New technique for treatment of unstable distal femur fractures by locked double-plating: case report and biomechanical evaluation","volume":"48","author":"Jazrawi","year":"2000","journal-title":"J Trauma"},{"key":"R9-20250614","doi-asserted-by":"crossref","first-page":"2604","DOI":"10.1002\/jor.24047","article-title":"Is augmented LISS plating biomechanically advantageous over conventional LISS plating in unstable osteoporotic distal femoral fractures?","volume":"36","author":"Todorov","year":"2018","journal-title":"J Orthop Res."},{"key":"R10-20250614","doi-asserted-by":"crossref","first-page":"21","DOI":"10.5606\/ehc.2015.06","article-title":"Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability","volume":"26","author":"Ba\u015fc\u0131","year":"2015","journal-title":"Eklem Hast Cerrahisi"},{"key":"R11-20250614","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1097\/BOT.0000000000001591","article-title":"Supplementation of lateral locked plating for distal femur fractures: a biomechanical study","volume":"33","author":"Fontenot","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R12-20250614","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1097\/BOT.0000000000001749","article-title":"Supplemental fixation of supracondylar distal femur fractures: a biomechanical comparison of dual-plate and plate-nail constructs","volume":"34","author":"Wright","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R13-20250614","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.injury.2021.11.011","article-title":"Distal femoral fractures: a comparison between single lateral plate fixation and a combined femoral nail and plate fixation","volume":"53","author":"Garala","year":"2022","journal-title":"Injury"},{"key":"R14-20250614","doi-asserted-by":"crossref","first-page":"e237","DOI":"10.1097\/BOT.0000000000001154","article-title":"Stable fixation and immediate weight-bearing after combined retrograde intramedullary nailing and open reduction internal fixation of noncomminuted distal interprosthetic femur fractures","volume":"32","author":"Hussain","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R15-20250614","doi-asserted-by":"crossref","first-page":"110018","DOI":"10.1016\/j.jbiomech.2020.110018","article-title":"Evaluating the mechanical response of novel synthetic femurs for representing osteoporotic bone","volume":"111","author":"Gluek","year":"2020","journal-title":"J Biomech."},{"key":"R16-20250614","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s10439-009-9887-7","article-title":"Mechanical evaluation of large-size fourth-generation composite femur and tibia models","volume":"38","author":"Gardner","year":"2010","journal-title":"Ann Biomed Eng."}],"container-title":["Journal of Orthopaedic Trauma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002594","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T18:03:26Z","timestamp":1749924206000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BOT.0000000000002594"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":16,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bot.0000000000002594","relation":{},"ISSN":["0890-5339"],"issn-type":[{"type":"print","value":"0890-5339"}],"subject":[],"published":{"date-parts":[[2023,7]]},"assertion":[{"value":"2023-02-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}